Medium-Term Observation of Dalbo-Rotex Retention Elements: A Retrospective Cohort Study.

Salome D Zimmermann, Laurent Liecht, Nicola U Zitzmann, Tim Joda
{"title":"Medium-Term Observation of Dalbo-Rotex Retention Elements: A Retrospective Cohort Study.","authors":"Salome D Zimmermann, Laurent Liecht, Nicola U Zitzmann, Tim Joda","doi":"10.11607/ijp.8669","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the medium-term survival of Dalbo-Rotex retention elements, identify potential risk factors for complication or loss, and to consider economic factors.</p><p><strong>Materials and methods: </strong>Patients treated with Dalbo-Rotex retention elements in a university setting were retrospectively identified and examined. Clinical data comprised assessments of the dental, periodontal, endodontic, and prosthetic situation, including radiographic analysis. Patient satisfaction was quantified with visual analog scale questionnaires. Five-year Kaplan-Meier plots for relative survival and success rates were calculated.</p><p><strong>Results: </strong>The 45 included patients had a total of 76 Dalbo-Rotex retention elements. Twelve Dalbo-Rotex elements failed and complications occurred in 42.1% of elements, equating to a survival rate of 84.2% and a success rate of 47.4% after a mean observation period of 49.2 months (SD 52.4, range 6-219 months). The 5-year cumulative survival and success rate was 62.4% (95% CI 44.0-88.4%) and 35.6% (95% CI 23.8-53.2%), respectively. Patients' self-assessment of prostheses retention was rated at 82 (IQR 40-92.2) with low pain perception at 4.5 (IQR 0-30). Probing pocket depth levels were significantly reduced in patients adhering to a regular recall interval compared with those with longer intervals.</p><p><strong>Conclusions: </strong>Chairside Dalbo-Rotex retention elements are a straightforward chairside method for prostheses retention that achieve good survival over medium-term follow up with high patient satisfaction. This technique is therefore a viable alternative to cast post copings that may be particularly valuable for patients with limited financial resources.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.8669","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the medium-term survival of Dalbo-Rotex retention elements, identify potential risk factors for complication or loss, and to consider economic factors.

Materials and methods: Patients treated with Dalbo-Rotex retention elements in a university setting were retrospectively identified and examined. Clinical data comprised assessments of the dental, periodontal, endodontic, and prosthetic situation, including radiographic analysis. Patient satisfaction was quantified with visual analog scale questionnaires. Five-year Kaplan-Meier plots for relative survival and success rates were calculated.

Results: The 45 included patients had a total of 76 Dalbo-Rotex retention elements. Twelve Dalbo-Rotex elements failed and complications occurred in 42.1% of elements, equating to a survival rate of 84.2% and a success rate of 47.4% after a mean observation period of 49.2 months (SD 52.4, range 6-219 months). The 5-year cumulative survival and success rate was 62.4% (95% CI 44.0-88.4%) and 35.6% (95% CI 23.8-53.2%), respectively. Patients' self-assessment of prostheses retention was rated at 82 (IQR 40-92.2) with low pain perception at 4.5 (IQR 0-30). Probing pocket depth levels were significantly reduced in patients adhering to a regular recall interval compared with those with longer intervals.

Conclusions: Chairside Dalbo-Rotex retention elements are a straightforward chairside method for prostheses retention that achieve good survival over medium-term follow up with high patient satisfaction. This technique is therefore a viable alternative to cast post copings that may be particularly valuable for patients with limited financial resources.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dalbo-Rotex Retention Elements 的中期观察:回顾性队列研究
目的:调查Dalbo-Rotex留置元件的中期存活率,确定并发症或损失的潜在风险因素,并考虑经济因素:对在一所大学接受过Dalbo-Rotex固位体治疗的患者进行回顾性鉴定和检查。临床数据包括对牙齿、牙周、牙髓和修复情况的评估,包括放射学分析。患者满意度通过视觉模拟量表问卷进行量化。计算了五年相对存活率和成功率的卡普兰-梅耶图:结果:45名患者共使用了76个Dalbo-Rotex固位体。平均观察期为 49.2 个月(标准差 52.4,范围为 6-219 个月),其中有 12 个 Dalbo-Rotex 元件失败,42.1%的元件出现并发症,存活率为 84.2%,成功率为 47.4%。5年累计存活率和成功率分别为62.4%(95% CI 44.0-88.4%)和35.6%(95% CI 23.8-53.2%)。患者对义齿固位的自我评估为 82(IQR 40-92.2),低疼痛感为 4.5(IQR 0-30)。与间隔时间较长的患者相比,坚持定期复查的患者探查袋深度水平明显降低:椅旁Dalbo-Rotex固位元件是一种简单的椅旁义齿固位方法,在中期随访中的存活率很高,患者满意度也很高。因此,这种技术是石膏后牙托的一种可行替代方法,对于经济条件有限的患者尤为重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
IN VITRO SURVIVAL AND FRACTURE FORCE OF LITHIUM DISILICATE HYBRID ABUTMENT CROWNS. Influence of Implant ScanBody Material and Intraoral Scanners on the Accuracy of Complete-Arch Digital Implant Impressions. A Cross-Sectional Study of Temporomandibular Disorders Among Postgraduate Students. Translucency Parameters and Masking Abilities of Monolithic CAD/CAM Ceramics. A Comparison of Occlusal Schemes with Condylar Inclination and Anterior Guidance in Dentate Individuals.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1