{"title":"Measurement properties of the EQ-5D-3L, EQ-5D-5L, and SF-6Dv2 in patients with late-onset Pompe disease.","authors":"Richard Huan Xu, Nan Luo, Dong Dong","doi":"10.1007/s10198-024-01682-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective of this study was to evaluate the psychometric properties of the EQ-5D (3L and 5L) and SF-6Dv2 in a group of Chinese patients with late-on Pompe disease (PD), and compare their performance in this patient group.</p><p><strong>Methods: </strong>The data used in this study were obtained from a web-based and cross-sectional survey conducted in China. All participants completed the 3L, 5L, and SF-6Dv2. Information about their sociodemographic status and health conditions was also collected. The measurement properties were assessed by examining ceiling and floor effects, evaluating convergent validity, known-group validity, and test-retest reliability (Intraclass correlation coefficient [ICC] and Gwet's AC).</p><p><strong>Results: </strong>A total of 117 PD patients completed the questionnaire. All dimensions of the 3L showed strong ceiling effects, ranging between 17.1 and 42.7%. All three measures showed good test-retest reliability, with ICC values ranging from 0.85 to 0.87. The Gwet's AC values showed that four out of five dimensions of the 3L showed very good agreement. All hypothesized correlations between the 3L, 5L, SF-6Dv2, and items of WHODAS were supported, indicating satisfactory convergent validity. The 5L showed stronger correlations (|r|= 0.53-0.84) with WHODAS than the other two measures. The outcomes of ANOVA indicated that the 5L had higher F-statistics than the 3L and SF-6Dv2, indicating a stronger discriminant ability to differentiate most condition groups.</p><p><strong>Conclusion: </strong>The 5L demonstrates lower ceiling and floor effects, higher discriminant ability, and better convergent validity than the SF-6Dv2 and 3L in patients with PD. In addition, the 5L may generate a larger utility gain compared to the other two instruments when conducting cost-effectiveness analysis.</p>","PeriodicalId":51416,"journal":{"name":"European Journal of Health Economics","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11512824/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Health Economics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10198-024-01682-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/12 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ECONOMICS","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The objective of this study was to evaluate the psychometric properties of the EQ-5D (3L and 5L) and SF-6Dv2 in a group of Chinese patients with late-on Pompe disease (PD), and compare their performance in this patient group.
Methods: The data used in this study were obtained from a web-based and cross-sectional survey conducted in China. All participants completed the 3L, 5L, and SF-6Dv2. Information about their sociodemographic status and health conditions was also collected. The measurement properties were assessed by examining ceiling and floor effects, evaluating convergent validity, known-group validity, and test-retest reliability (Intraclass correlation coefficient [ICC] and Gwet's AC).
Results: A total of 117 PD patients completed the questionnaire. All dimensions of the 3L showed strong ceiling effects, ranging between 17.1 and 42.7%. All three measures showed good test-retest reliability, with ICC values ranging from 0.85 to 0.87. The Gwet's AC values showed that four out of five dimensions of the 3L showed very good agreement. All hypothesized correlations between the 3L, 5L, SF-6Dv2, and items of WHODAS were supported, indicating satisfactory convergent validity. The 5L showed stronger correlations (|r|= 0.53-0.84) with WHODAS than the other two measures. The outcomes of ANOVA indicated that the 5L had higher F-statistics than the 3L and SF-6Dv2, indicating a stronger discriminant ability to differentiate most condition groups.
Conclusion: The 5L demonstrates lower ceiling and floor effects, higher discriminant ability, and better convergent validity than the SF-6Dv2 and 3L in patients with PD. In addition, the 5L may generate a larger utility gain compared to the other two instruments when conducting cost-effectiveness analysis.
期刊介绍:
The European Journal of Health Economics is a journal of Health Economics and associated disciplines. The growing demand for health economics and the introduction of new guidelines in various European countries were the motivation to generate a highly scientific and at the same time practice oriented journal considering the requirements of various health care systems in Europe. The international scientific board of opinion leaders guarantees high-quality, peer-reviewed publications as well as articles for pragmatic approaches in the field of health economics. We intend to cover all aspects of health economics:
• Basics of health economic approaches and methods
• Pharmacoeconomics
• Health Care Systems
• Pricing and Reimbursement Systems
• Quality-of-Life-Studies The editors reserve the right to reject manuscripts that do not comply with the above-mentioned requirements. The author will be held responsible for false statements or for failure to fulfill the above-mentioned requirements.
Officially cited as: Eur J Health Econ