Usefulness of Schirmer's tear strips and borosilicate glass tubes in chemical analysis of human tear fluid: A practical check in VEGF detection.

IF 1.4 4区 医学 Q3 OPHTHALMOLOGY European Journal of Ophthalmology Pub Date : 2024-11-01 Epub Date: 2024-03-14 DOI:10.1177/11206721241238879
Janusz Pieczyński, Jolanta Kiewisz
{"title":"Usefulness of Schirmer's tear strips and borosilicate glass tubes in chemical analysis of human tear fluid: A practical check in VEGF detection.","authors":"Janusz Pieczyński, Jolanta Kiewisz","doi":"10.1177/11206721241238879","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Human tears contain a number of agents which may play an important role in diagnosing local eye disorders as well as systemic diseases. The small amount of fluid obtained during the collection and the consequent difficulty in analysing it are the main problems encountered in the diagnostic process.</p><p><strong>Aim: </strong>We decided to investigate the practical usefulness of two simple methods of collecting tear fluid for chemical analysis, i.e., glass tubes and Schirmer's strips. The substance analyzed was vascular endothelial growth factor (VEGF), a compound commonly recognized in ophthalmology.</p><p><strong>Methods: </strong>We used standard Schirmer's tear test and calibrated glass tubes for tear fluid collection in healthy volunteers. The standard ELISA assay was used to check the effectiveness of the tear sampling by estimating the VEGF level.</p><p><strong>Results: </strong>The results of the study show that Schirmer's tear strip test is a more effective tool of the two. Moreover, using Schirmer's strips to obtain tear fluid was found to be more patient friendly and amounts of the tear fluid collected with that test were enough and better for the VEGF detection.</p><p><strong>Conclusions: </strong>Our study indicates that the widely used Schirmer tear test may be the best method of tear collection for chemical analysis. However, further studies on test calibration are needed.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241238879","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Human tears contain a number of agents which may play an important role in diagnosing local eye disorders as well as systemic diseases. The small amount of fluid obtained during the collection and the consequent difficulty in analysing it are the main problems encountered in the diagnostic process.

Aim: We decided to investigate the practical usefulness of two simple methods of collecting tear fluid for chemical analysis, i.e., glass tubes and Schirmer's strips. The substance analyzed was vascular endothelial growth factor (VEGF), a compound commonly recognized in ophthalmology.

Methods: We used standard Schirmer's tear test and calibrated glass tubes for tear fluid collection in healthy volunteers. The standard ELISA assay was used to check the effectiveness of the tear sampling by estimating the VEGF level.

Results: The results of the study show that Schirmer's tear strip test is a more effective tool of the two. Moreover, using Schirmer's strips to obtain tear fluid was found to be more patient friendly and amounts of the tear fluid collected with that test were enough and better for the VEGF detection.

Conclusions: Our study indicates that the widely used Schirmer tear test may be the best method of tear collection for chemical analysis. However, further studies on test calibration are needed.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
施尔默泪液条和硼硅玻璃管在人体泪液化学分析中的用途:血管内皮生长因子检测的实际检验。
导言:人类泪液中含有多种成分,这些成分在诊断局部眼部疾病和全身性疾病方面可能发挥重要作用。目的:我们决定研究收集泪液进行化学分析的两种简单方法(即玻璃管和施尔默试纸)的实用性。分析的物质是血管内皮生长因子(VEGF),这是一种眼科常见的化合物:方法:我们使用标准的施尔默泪液测试法和校准过的玻璃管收集健康志愿者的泪液。方法:我们使用标准的施尔默泪液测试法和校准玻璃管对健康志愿者的泪液进行采集,并使用标准的 ELISA 检测法通过估算血管内皮生长因子的水平来检查泪液采样的有效性:研究结果表明,施尔默泪液条检测法是两种检测方法中更有效的一种。此外,使用施尔默泪液条采集泪液对患者更友好,而且采集的泪液量充足,更有利于血管内皮生长因子的检测:我们的研究表明,广泛使用的施尔默泪液测试法可能是收集泪液进行化学分析的最佳方法。结论:我们的研究表明,广泛使用的施尔默泪液测试法可能是进行化学分析的最佳泪液采集方法,但还需要对测试校准进行进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
372
审稿时长
3-8 weeks
期刊介绍: The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.
期刊最新文献
Acute infectious endophthalmitis after chandelier-assisted scleral buckling surgery. Bagel sign and how to avoid it in DMEK surgery. Changes in choroidal thickness and lamina cribrosa position in subjects with overdipper pattern of arterial pressure. Characteristics of submacular hemorrhage with bacillary layer detachment and intrabacillary hemorrhage. Comparison of 3-month clinical outcomes between two enhanced monofocal intraocular lenses: A single-center prospective study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1