Ishwor Gautam, Avi Shaw, Dhiren Brickman, Ajay Mahajan, Anita Jeyakumar
{"title":"Creation of a Prototype Cochlear Training Model.","authors":"Ishwor Gautam, Avi Shaw, Dhiren Brickman, Ajay Mahajan, Anita Jeyakumar","doi":"10.1177/00034894241238868","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Creation of a novel 3D-printed physical cochlear model that demonstrated the feasibility of creating the model, and impact of a Graphical User Interface (GUI) system on training insertion metrics.</p><p><strong>Study design: </strong>Feasibility study with a pilot prospective data collection.</p><p><strong>Setting: </strong>Tertiary academic center.</p><p><strong>Methods: </strong>The study was IRB exempt. Five resident trainees (PGY1-PGY5) practiced electrode insertions in cadaveric temporal bones before using the simulator. Nine students were educated on how to hold the electrodes and position them, and then allowed to use the simulator. All trainees were instructed that slower insertions were favorable. One cochlear implant (CI) surgeon used the simulator. The GUI captured the real video feed, but also provided distance, trajectory, and velocity measurements. The program is designed to plot the real-time depth of insertion and speed of insertion of the electrode; the user is also provided real-time occurrence of any kinks and back-outs.</p><p><strong>Results: </strong>A total of 14 trainees and 1 CI surgeon inserted the electrode at least 5 times without the use of the GUI (before) and then at least 5 times with the use of the GUI (after). Average Speed before and after (100.84 and 53.23 mm/s); Average minimum speed before and after (59.34 and 9.65 mm/s); and Average maximum speed before and after (416 and 285.81 mm/s). Statistically significant improvements were noted in all the measured speeds of insertion (<i>P</i> < .001). The other variables improved but not to a statistical significance.</p><p><strong>Conclusions: </strong>Real-time training using the 3D-printed model and GUI for cochlear implantation can help improve surgical resident training and comfort levels with electrode insertion for surgical trainees. The advantage of this model is that surgeons/trainees can use it as many times as they like, as the whole set-up is easy, economical, and reusable. The real time graphical user interface enhances training and retention of the practiced skills.</p>","PeriodicalId":50975,"journal":{"name":"Annals of Otology Rhinology and Laryngology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Otology Rhinology and Laryngology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00034894241238868","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/16 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Creation of a novel 3D-printed physical cochlear model that demonstrated the feasibility of creating the model, and impact of a Graphical User Interface (GUI) system on training insertion metrics.
Study design: Feasibility study with a pilot prospective data collection.
Setting: Tertiary academic center.
Methods: The study was IRB exempt. Five resident trainees (PGY1-PGY5) practiced electrode insertions in cadaveric temporal bones before using the simulator. Nine students were educated on how to hold the electrodes and position them, and then allowed to use the simulator. All trainees were instructed that slower insertions were favorable. One cochlear implant (CI) surgeon used the simulator. The GUI captured the real video feed, but also provided distance, trajectory, and velocity measurements. The program is designed to plot the real-time depth of insertion and speed of insertion of the electrode; the user is also provided real-time occurrence of any kinks and back-outs.
Results: A total of 14 trainees and 1 CI surgeon inserted the electrode at least 5 times without the use of the GUI (before) and then at least 5 times with the use of the GUI (after). Average Speed before and after (100.84 and 53.23 mm/s); Average minimum speed before and after (59.34 and 9.65 mm/s); and Average maximum speed before and after (416 and 285.81 mm/s). Statistically significant improvements were noted in all the measured speeds of insertion (P < .001). The other variables improved but not to a statistical significance.
Conclusions: Real-time training using the 3D-printed model and GUI for cochlear implantation can help improve surgical resident training and comfort levels with electrode insertion for surgical trainees. The advantage of this model is that surgeons/trainees can use it as many times as they like, as the whole set-up is easy, economical, and reusable. The real time graphical user interface enhances training and retention of the practiced skills.
期刊介绍:
The Annals of Otology, Rhinology & Laryngology publishes original manuscripts of clinical and research importance in otolaryngology–head and neck medicine and surgery, otology, neurotology, bronchoesophagology, laryngology, rhinology, head and neck oncology and surgery, plastic and reconstructive surgery, pediatric otolaryngology, audiology, and speech pathology. In-depth studies (supplements), papers of historical interest, and reviews of computer software and applications in otolaryngology are also published, as well as imaging, pathology, and clinicopathology studies, book reviews, and letters to the editor. AOR is the official journal of the American Broncho-Esophagological Association.