Operational cost and wind power integration capacities of the integrated heat and power dispatch (IHPD) system under different heating regulation modes and time steps

IF 3.2 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Indoor and Built Environment Pub Date : 2024-03-16 DOI:10.1177/1420326x241239237
Xuexiang Zhang, Jinfu Zheng, Hui Zhu, Songtao Hu, Shimin Liang
{"title":"Operational cost and wind power integration capacities of the integrated heat and power dispatch (IHPD) system under different heating regulation modes and time steps","authors":"Xuexiang Zhang, Jinfu Zheng, Hui Zhu, Songtao Hu, Shimin Liang","doi":"10.1177/1420326x241239237","DOIUrl":null,"url":null,"abstract":"The utilization of the district heating system (DHS) thermal inertia is greatly influenced by heating regulation modes and time steps, however, which has been rarely analysed in almost all integrated heat and power dispatch system (IHPD) models, for the purpose of wind power integration. In this study, an IHPD model considering the thermal inertia of the DHS was established, in which a data interaction problem amongst the power sources, heat sources and district heating networks was solved. Thereafter, four most commonly used heating operation modes and different heating regulation time steps were applied to the IHPD model, respectively, to analyse and compare their effects on the IHPD system under different operation conditions, mainly considering the operation cost and the wind power integration. Results of the case studies showed that the variable flow and variable supply temperature mode produced the lowest operation cost of the IHPD system during a whole heating season. Consequently, this mode is recommended to be applied in the optimization operation of the IHPD system with the wind power integration. Meanwhile, a heating regulation time step within 3 h could make full use of the DHS thermal inertia, thus to improve the operational flexibility of the IHPD system.","PeriodicalId":13578,"journal":{"name":"Indoor and Built Environment","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor and Built Environment","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/1420326x241239237","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The utilization of the district heating system (DHS) thermal inertia is greatly influenced by heating regulation modes and time steps, however, which has been rarely analysed in almost all integrated heat and power dispatch system (IHPD) models, for the purpose of wind power integration. In this study, an IHPD model considering the thermal inertia of the DHS was established, in which a data interaction problem amongst the power sources, heat sources and district heating networks was solved. Thereafter, four most commonly used heating operation modes and different heating regulation time steps were applied to the IHPD model, respectively, to analyse and compare their effects on the IHPD system under different operation conditions, mainly considering the operation cost and the wind power integration. Results of the case studies showed that the variable flow and variable supply temperature mode produced the lowest operation cost of the IHPD system during a whole heating season. Consequently, this mode is recommended to be applied in the optimization operation of the IHPD system with the wind power integration. Meanwhile, a heating regulation time step within 3 h could make full use of the DHS thermal inertia, thus to improve the operational flexibility of the IHPD system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同供热调节模式和时间步长下的热电综合调度(IHPD)系统的运行成本和风电集成能力
区域供热系统(DHS)热惯性的利用在很大程度上受到供热调节模式和时间步骤的影响,但几乎所有以风电一体化为目的的热电一体化调度系统(IHPD)模型都很少对此进行分析。本研究建立了一个考虑到区域供热系统热惯性的 IHPD 模型,其中解决了电源、热源和区域供热网络之间的数据交互问题。随后,将四种最常用的供热运行模式和不同的供热调节时间步骤分别应用到 IHPD 模型中,分析和比较了它们在不同运行条件下对 IHPD 系统的影响,主要考虑了运行成本和风电集成。案例研究结果表明,在整个采暖季期间,变流量和变供水温度模式产生的 IHPD 系统运行成本最低。因此,建议将该模式应用于风电一体化 IHPD 系统的优化运行中。同时,3 h 内的供热调节时间步长可充分利用 DHS 的热惯性,从而提高 IHPD 系统的运行灵活性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indoor and Built Environment
Indoor and Built Environment 环境科学-工程:环境
CiteScore
6.40
自引率
25.00%
发文量
130
审稿时长
2.6 months
期刊介绍: Indoor and Built Environment publishes reports on any topic pertaining to the quality of the indoor and built environment, and how these might effect the health, performance, efficiency and comfort of persons living or working there. Topics range from urban infrastructure, design of buildings, and materials used to laboratory studies including building airflow simulations and health effects. This journal is a member of the Committee on Publication Ethics (COPE).
期刊最新文献
Dynamics of indoor volatile organic compounds and seasonal ventilation strategies for residential buildings in Northeast China The indoor thermal environment performance of various air-conditioning system configurations and airflow modes in a large space museum building Leakage identification and correlation coefficient method for industrial workshop production process combining with computational fluid dynamics Synthesis and performance study of biomass-based suppressant and its application in radioactive aerosol sedimentation Modelling of radiation and flow fields in in-duct ultraviolet germicidal irradiation systems with and without ribs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1