Tibial Plateau Angle Measurement in Dogs – Comparison of Three Different Methods

Anastasija Z. Todorović, Nikola E. Krstić, Dragan R. Žikić, Henri JJ. Van Bree, Ingrid Mlv. Gielen, Mirjana V. Lazarević Macanović
{"title":"Tibial Plateau Angle Measurement in Dogs – Comparison of Three Different Methods","authors":"Anastasija Z. Todorović, Nikola E. Krstić, Dragan R. Žikić, Henri JJ. Van Bree, Ingrid Mlv. Gielen, Mirjana V. Lazarević Macanović","doi":"10.2478/acve-2024-0002","DOIUrl":null,"url":null,"abstract":"The aim of this study was to establish two new methods for measuring the tibial plateau angle (TPA): proximal tibial circle (PTC) as well as full tibial circle (FTC) method, and to test their reliability in comparison to the classical method (CM). Three radiologists implemented each method, and measurements were repeated three times. The results of consecutive measurements obtained by two observers had excellent reliability with an interclass correlation coefficient (ICC) greater than 0.9 for all methods, while measurements obtained by the third observer had good reliability for the CM (ICC=0.885) and PTC method (ICC=0.851). The results obtained by the three observers for all methods indicate good reliability for the PTC and FTC methods (ICC=0.848 and 0.880, respectively) and excellent reliability for CM (ICC = 0.909); the results of the different observers for each method were not significantly different. The significant difference resulting from the applied measurement method (ICC = 0.447 and P<0.01) was confirmed. Statistically significant differences were not found between the CM and PTC method (P>0.05), while differences between the PTC and FTC, as well as CM and FTC methods, were statistically significant (P<0.01). New methods for TPA measurements based on shorter tibial axes may be an alternative to a method based on the full-length axis. A high correlation between the methods indicates the precision of each of them. Newly established methods can be used when the tarsal joint is not included in radiographs or is affected by degenerative changes, making use of the classical method not possible.","PeriodicalId":7379,"journal":{"name":"Acta Veterinaria","volume":"155 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Veterinaria","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/acve-2024-0002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to establish two new methods for measuring the tibial plateau angle (TPA): proximal tibial circle (PTC) as well as full tibial circle (FTC) method, and to test their reliability in comparison to the classical method (CM). Three radiologists implemented each method, and measurements were repeated three times. The results of consecutive measurements obtained by two observers had excellent reliability with an interclass correlation coefficient (ICC) greater than 0.9 for all methods, while measurements obtained by the third observer had good reliability for the CM (ICC=0.885) and PTC method (ICC=0.851). The results obtained by the three observers for all methods indicate good reliability for the PTC and FTC methods (ICC=0.848 and 0.880, respectively) and excellent reliability for CM (ICC = 0.909); the results of the different observers for each method were not significantly different. The significant difference resulting from the applied measurement method (ICC = 0.447 and P<0.01) was confirmed. Statistically significant differences were not found between the CM and PTC method (P>0.05), while differences between the PTC and FTC, as well as CM and FTC methods, were statistically significant (P<0.01). New methods for TPA measurements based on shorter tibial axes may be an alternative to a method based on the full-length axis. A high correlation between the methods indicates the precision of each of them. Newly established methods can be used when the tarsal joint is not included in radiographs or is affected by degenerative changes, making use of the classical method not possible.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
狗的胫骨平台角度测量 - 三种不同方法的比较
本研究的目的是建立两种测量胫骨平台角(TPA)的新方法:胫骨近端圆周法(PTC)和胫骨全圆周法(FTC),并与经典方法(CM)进行比较,测试其可靠性。每种方法均由三名放射科医生实施,重复测量三次。由两名观察者进行的连续测量结果可靠性极佳,所有方法的类间相关系数(ICC)均大于 0.9,而由第三名观察者进行的测量结果,CM 法(ICC=0.885)和 PTC 法(ICC=0.851)的可靠性较好。三位观察者对所有方法得出的结果表明,PTC 和 FTC 方法的可靠性良好(ICC 分别为 0.848 和 0.880),CM 方法的可靠性极佳(ICC = 0.909);不同观察者对每种方法得出的结果没有显著差异。所采用的测量方法导致的显著差异(ICC = 0.447,P<0.01)得到了证实。CM 和 PTC 方法之间的差异无统计学意义(P>0.05),而 PTC 和 FTC 以及 CM 和 FTC 方法之间的差异有统计学意义(P<0.01)。基于较短胫骨轴线的 TPA 测量新方法可替代基于全长轴线的方法。这些方法之间的高度相关性表明了每种方法的精确性。当跗关节不在X光片范围内或受退行性病变影响,无法使用传统方法时,可使用新建立的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Postmortem Finding of a Colloid Goiter in an American Black Bear (Ursus Americanus) Molecular Markers in Canine Mammary Tumors Determination of the 1L-5-6L MGF110 Genes Influence on the Biological Properties of the African Swine Fever Virus (Asfarviridae; Asfivirus) “Volgograd/14c” in vivo Congenital Hepatic Fibrosis in an Aborted Holstein-Friesian Fetus Early Detection of Candidate Genes for Body Weight in Indonesian Cattle Breeds with Genome-Wide Association Study (GWAS)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1