False-positive MDA findings in HRMS-based screening of putrefied postmortem blood samples-Identification of the interference as N-acetyltyramine.

IF 2.3 3区 医学 Q3 CHEMISTRY, ANALYTICAL Journal of analytical toxicology Pub Date : 2024-06-11 DOI:10.1093/jat/bkae015
Viviane C Stammer, Dirk K Wissenbach, Frank T Peters
{"title":"False-positive MDA findings in HRMS-based screening of putrefied postmortem blood samples-Identification of the interference as N-acetyltyramine.","authors":"Viviane C Stammer, Dirk K Wissenbach, Frank T Peters","doi":"10.1093/jat/bkae015","DOIUrl":null,"url":null,"abstract":"<p><p>An unidentified compound in putrefied postmortem blood samples showed identical accurate mass and chromatographic behavior as 3,4-methylenedioxyamphetamine (MDA) and led to false-positive preliminary screening results. The aim of the study was to identify this unknown interference. Postmortem blood samples were analyzed after protein precipitation on a QExactive Focus high-resolution mass spectrometer (Thermo Fisher, Germany) coupled to a RP C18 column (Macherey-Nagel, Germany). Based on the analysis of mass spectrometry (MS) adducts and isotope ratios using fullscan (m/z 134-330) information, the empiric formula of the protonated molecule [M + H]+ of the unknown compound was found to be C10H14O2N (+ 0.6 ppm). Product ion spectra recorded using normalized collision energy 22% showed a base peak of C8H9O1 (+ 1.5 ppm) and a low-abundant water loss to C7H9 (+ 1.9 ppm), neutral losses of C2H2O and NH3 were found. Based on fullscan and MS-MS information and under consideration of the observed order of neutral losses, the compound was presumptively identified as N-acetyltyramine. This assumption was supported by SIRIUS software showing a SIRIUS score of 99.43% for N-acetyltyramine. Finally, the putative structure annotation was confirmed by a reference compound. The described false-positive MDA findings could be attributed to the presence of N-acetyltyramine in putrefied blood samples. Being an isomer of MDA, N-acetyltyramine could not be distinguished by high-resolution data of the protonated molecules. The presented results once again highlight that false-positive findings may occur even in hyphenated high-resolution mass spectrometry (HRMS) when using full-scan information only.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":"393-397"},"PeriodicalIF":2.3000,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkae015","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

An unidentified compound in putrefied postmortem blood samples showed identical accurate mass and chromatographic behavior as 3,4-methylenedioxyamphetamine (MDA) and led to false-positive preliminary screening results. The aim of the study was to identify this unknown interference. Postmortem blood samples were analyzed after protein precipitation on a QExactive Focus high-resolution mass spectrometer (Thermo Fisher, Germany) coupled to a RP C18 column (Macherey-Nagel, Germany). Based on the analysis of mass spectrometry (MS) adducts and isotope ratios using fullscan (m/z 134-330) information, the empiric formula of the protonated molecule [M + H]+ of the unknown compound was found to be C10H14O2N (+ 0.6 ppm). Product ion spectra recorded using normalized collision energy 22% showed a base peak of C8H9O1 (+ 1.5 ppm) and a low-abundant water loss to C7H9 (+ 1.9 ppm), neutral losses of C2H2O and NH3 were found. Based on fullscan and MS-MS information and under consideration of the observed order of neutral losses, the compound was presumptively identified as N-acetyltyramine. This assumption was supported by SIRIUS software showing a SIRIUS score of 99.43% for N-acetyltyramine. Finally, the putative structure annotation was confirmed by a reference compound. The described false-positive MDA findings could be attributed to the presence of N-acetyltyramine in putrefied blood samples. Being an isomer of MDA, N-acetyltyramine could not be distinguished by high-resolution data of the protonated molecules. The presented results once again highlight that false-positive findings may occur even in hyphenated high-resolution mass spectrometry (HRMS) when using full-scan information only.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于 HRMS 的腐尸血液样本筛查中的 MDA 假阳性结果--确定干扰物为 N-乙酰酪胺。
腐尸血液样本中的一种不明化合物显示出与 3,4-亚甲二氧基苯丙胺(MDA)相同的精确质量和色谱行为,并导致初步筛查结果呈假阳性。这项研究的目的就是要找出这种未知的干扰。尸体血液样本经蛋白质沉淀后,在 QExactive Focus 高分辨率质谱仪(赛默飞世尔,德国)和 RP C18 色谱柱(马赫瑞-纳格尔,德国)上进行分析。根据使用 fullscan(m/z 134-330)信息对质谱(MS)加合物和同位素比率的分析,发现未知化合物质子化分子 [M + H]+ 的经验公式为 C10H14O2N (+ 0.6 ppm)。使用归一化碰撞能 22% 记录的产物离子光谱显示出 C8H9O1 的基峰(+ 1.5 ppm)和 C7H9 的低大量水损失(+ 1.9 ppm),还发现了 C2H2O 和 NH3 的中性损失。根据全扫描和 MS-MS 信息,并考虑到观察到的中性损失顺序,该化合物被推定为 N-乙酰基酪胺。SIRIUS 软件显示,N-乙酰基酪胺的 SIRIUS 得分为 99.43%,从而支持了这一假设。最后,推定的结构注释得到了参考化合物的证实。所描述的 MDA 假阳性结果可能是由于 N-乙酰基酪胺存在于腐败血液样本中。作为 MDA 的异构体,质子化分子的高分辨率数据无法区分 N-乙酰基酪胺。上述结果再次凸显出,即使是连用高分辨率质谱法(HRMS),如果仅使用全扫描信息,也可能出现假阳性结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
20.00%
发文量
92
审稿时长
6-12 weeks
期刊介绍: The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation. Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.
期刊最新文献
Post-mortem distribution of MDPHP in a fatal intoxication case. Trends in Central/Peripheral Ratio of Fentanyl in Harris County, TX and Orange County, CA from 2009-2020. LC-MS/MS confirmation of 11-nor-9-carboxy-tetrahydrocannabinol (Δ8, Δ9, Δ1°) and hexahydrocannabinol (HHC) metabolites in authentic urine specimens. NSC-ADID Position Statement on Performance Impairment in Safety-Sensitive Positions Related to Cannabis and Other Cannabinoids. Optimization of a disposable pipette tips extraction (DPX) for the analysis of psychoactive substances in sweat specimens using Design of Experiments.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1