Solid-contact ion-selective sensor for the direct determination of procyclidine HCl and application of in-line dissolution profiling of its tablets

IF 2.3 3区 化学 Q2 CHEMISTRY, ANALYTICAL Electroanalysis Pub Date : 2024-03-17 DOI:10.1002/elan.202300363
Radwa Ahmed Gaber, Nagiba Y. Hassan, Nesrin K. Ramadan, Mona T. Ragab
{"title":"Solid-contact ion-selective sensor for the direct determination of procyclidine HCl and application of in-line dissolution profiling of its tablets","authors":"Radwa Ahmed Gaber,&nbsp;Nagiba Y. Hassan,&nbsp;Nesrin K. Ramadan,&nbsp;Mona T. Ragab","doi":"10.1002/elan.202300363","DOIUrl":null,"url":null,"abstract":"<p>The ability to obtain accurate analytical results without sample pre-treatment or derivatization is a key element for an eco-friendly method of analysis. In this work, green electro analytical method was developed and evaluated for the selective determination of the anti-cholinergic drug Procyclidine Hydrochloride in both pure and dosage forms as well as in dissolution medium without sample pre-treatment. Firstly, screening of four ionophore-doped polyvinyl chloride-based membranes were conducted to detect the one with highest affinity towards the studied drug. Accordingly, calix[4]arene-doped membrane exhibited the optimum results. Then optimization was carried out by designing screen-printed and glassy carbon solid-contact ion-selective electrodes with multiwall carbon nanotube and graphene nanocomposite as ion to electron transducers. The fabricated screen-printed sensor with graphene nanocomposite was characterized according to IUPAC recommendations. It acquired the fastest and most stable response, along with thermal stability up to 30 °C. It also displayed a slope of 43.9±0.2 mV/decade in a pH range of 2–5. The proposed sensor successfully obtained a linear range of 1×10<sup>−5</sup>–1×10<sup>−2</sup> M and the theoretical limit of detection was 6.3×10<sup>−6</sup> M. Finally, it was used in applications such as in-line dissolution monitoring and quantification of procyclidine in its dosage form without prior sample pre-treatment or derivatization steps. Furthermore, the graphene nanocomposite transducer has been imaged by Scanning Electron Microscope (SEM).</p>","PeriodicalId":162,"journal":{"name":"Electroanalysis","volume":"36 8","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroanalysis","FirstCategoryId":"92","ListUrlMain":"https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/10.1002/elan.202300363","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The ability to obtain accurate analytical results without sample pre-treatment or derivatization is a key element for an eco-friendly method of analysis. In this work, green electro analytical method was developed and evaluated for the selective determination of the anti-cholinergic drug Procyclidine Hydrochloride in both pure and dosage forms as well as in dissolution medium without sample pre-treatment. Firstly, screening of four ionophore-doped polyvinyl chloride-based membranes were conducted to detect the one with highest affinity towards the studied drug. Accordingly, calix[4]arene-doped membrane exhibited the optimum results. Then optimization was carried out by designing screen-printed and glassy carbon solid-contact ion-selective electrodes with multiwall carbon nanotube and graphene nanocomposite as ion to electron transducers. The fabricated screen-printed sensor with graphene nanocomposite was characterized according to IUPAC recommendations. It acquired the fastest and most stable response, along with thermal stability up to 30 °C. It also displayed a slope of 43.9±0.2 mV/decade in a pH range of 2–5. The proposed sensor successfully obtained a linear range of 1×10−5–1×10−2 M and the theoretical limit of detection was 6.3×10−6 M. Finally, it was used in applications such as in-line dissolution monitoring and quantification of procyclidine in its dosage form without prior sample pre-treatment or derivatization steps. Furthermore, the graphene nanocomposite transducer has been imaged by Scanning Electron Microscope (SEM).

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于直接测定盐酸普罗环利啶及其片剂在线溶出度分析应用的固体接触式离子选择传感器
na
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Electroanalysis
Electroanalysis 化学-电化学
CiteScore
6.00
自引率
3.30%
发文量
222
审稿时长
2.4 months
期刊介绍: Electroanalysis is an international, peer-reviewed journal covering all branches of electroanalytical chemistry, including both fundamental and application papers as well as reviews dealing with new electrochemical sensors and biosensors, nanobioelectronics devices, analytical voltammetry, potentiometry, new electrochemical detection schemes based on novel nanomaterials, fuel cells and biofuel cells, and important practical applications. Serving as a vital communication link between the research labs and the field, Electroanalysis helps you to quickly adapt the latest innovations into practical clinical, environmental, food analysis, industrial and energy-related applications. Electroanalysis provides the most comprehensive coverage of the field and is the number one source for information on electroanalytical chemistry, electrochemical sensors and biosensors and fuel/biofuel cells.
期刊最新文献
Biorecognition Elements Driving Electrochemical Biosensors for Detecting Biological and Chemical Contaminants in Food: Progress and Challenges Biorecognition Elements Driving Electrochemical Biosensors for Detecting Biological and Chemical Contaminants in Food: Progress and Challenges MXene-Based Electrochemical Sensors: Design Strategies and Application Advances for the Detection of Biological Small Molecules MXene-Based Electrochemical Sensors: Design Strategies and Application Advances for the Detection of Biological Small Molecules Determination of Paraquat in Real Samples Using a Printed PET-Based Electrode Modified With Molecularly Imprinted Polymer and Carbonaceous Material
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1