Mohammad Mandegar Najafabadi, Hooman Angoorani, Jonathan Charest, Charles H Samuels, Kiana Bagherzadeh, Ahmad Nazari, Ali Mazaherinezhad
{"title":"The validity and reliability of the Persian version of the Athlete Sleep Screening Questionnaire.","authors":"Mohammad Mandegar Najafabadi, Hooman Angoorani, Jonathan Charest, Charles H Samuels, Kiana Bagherzadeh, Ahmad Nazari, Ali Mazaherinezhad","doi":"10.4103/jrms.jrms_246_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Sleep as a biological phenomenon is effective in the performance and recovery of athletes. Questionnaires can be used as a cost-effective initial assessment tool for sleep. The Athlete Sleep Screening Questionnaire (ASSQ) demonstrated a clinically valid instrument for screening relevant sleep issues in athletic populations. Due to the lack of validated tools for adequate screening for sleep difficulties in the Iranian athlete population, the present study was conducted to evaluate the validity and reliability of the Persian version of the ASSQ.</p><p><strong>Materials and methods: </strong>The translation process was performed using instructions by Beaton <i>et al</i>. Content validity was assessed by a panel of experts. Exploratory and confirmatory factor analysis was performed for two 5-item sleep difficulty scores (SDS) and a 4-item chronotype score. Internal consistency based on Cronbach's alpha and McDonald's omega and stability reliability were used to evaluate reliability.</p><p><strong>Results: </strong>The ASSQ achieved conceptual and semantic equivalence with the original scale. The item-level content validity index (I-CVI) of each item ranged from 0.87 to 1, and the averaging scale-level CVI/average was 0.95. In factor analysis, one factor for SDS and one factor for chronotype score were identified and confirmed. The internal consistency of the SDS scale (α =0.77, Ω =0.83) and chronotype (α =0.74, Ω =0.77) was acceptable. Stability reliability was confirmed for SDS scale (intra-class correlation [ICC] =0.87) and for chronotype (ICC = 0.83).</p><p><strong>Conclusion: </strong>Persian ASSQ has acceptable psychometric measurement properties as a screening tool to assess sleep in Iranian athletes.</p>","PeriodicalId":50062,"journal":{"name":"Journal of Research in Medical Sciences","volume":"29 ","pages":"1"},"PeriodicalIF":1.5000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10956700/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Research in Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/jrms.jrms_246_23","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Sleep as a biological phenomenon is effective in the performance and recovery of athletes. Questionnaires can be used as a cost-effective initial assessment tool for sleep. The Athlete Sleep Screening Questionnaire (ASSQ) demonstrated a clinically valid instrument for screening relevant sleep issues in athletic populations. Due to the lack of validated tools for adequate screening for sleep difficulties in the Iranian athlete population, the present study was conducted to evaluate the validity and reliability of the Persian version of the ASSQ.
Materials and methods: The translation process was performed using instructions by Beaton et al. Content validity was assessed by a panel of experts. Exploratory and confirmatory factor analysis was performed for two 5-item sleep difficulty scores (SDS) and a 4-item chronotype score. Internal consistency based on Cronbach's alpha and McDonald's omega and stability reliability were used to evaluate reliability.
Results: The ASSQ achieved conceptual and semantic equivalence with the original scale. The item-level content validity index (I-CVI) of each item ranged from 0.87 to 1, and the averaging scale-level CVI/average was 0.95. In factor analysis, one factor for SDS and one factor for chronotype score were identified and confirmed. The internal consistency of the SDS scale (α =0.77, Ω =0.83) and chronotype (α =0.74, Ω =0.77) was acceptable. Stability reliability was confirmed for SDS scale (intra-class correlation [ICC] =0.87) and for chronotype (ICC = 0.83).
Conclusion: Persian ASSQ has acceptable psychometric measurement properties as a screening tool to assess sleep in Iranian athletes.
期刊介绍:
Journal of Research in Medical Sciences, a publication of Isfahan University of Medical Sciences, is a peer-reviewed online continuous journal with print on demand compilation of issues published. The journal’s full text is available online at http://www.jmsjournal.net. The journal allows free access (Open Access) to its contents and permits authors to self-archive final accepted version of the articles on any OAI-compliant institutional / subject-based repository.