R. Sindi, B. Al-Shamrani, Aghadeer B. F. Al-Qurashi, M. Al-Qarhi, B. Al-Shehri, R. Al-Otaibi, N. Alomairy, N. Shubayr
{"title":"Impact of Implementing National Diagnostic Reference Levels on Radiation Dose Optimization in Adult Chest CT Scans: A Comparative Analysis","authors":"R. Sindi, B. Al-Shamrani, Aghadeer B. F. Al-Qurashi, M. Al-Qarhi, B. Al-Shehri, R. Al-Otaibi, N. Alomairy, N. Shubayr","doi":"10.1051/radiopro/2024011","DOIUrl":null,"url":null,"abstract":"The management and optimization of radiation dose in computed tomography (CT) examinations is of paramount importance, especially when the safety of patients is concerned. This study evaluated the effect of implementing national diagnostic reference levels (NDRLs) for radiation dose optimization in 1,991 adult chest CT scans at a major Saudi hospital. Data was analyzed before and after NDRL implementation, with 21.5% of scans using contrast and 78.5% without. Before implementation, 11.1% used contrast and 36.7% did not; after implementation, 10.4% used contrast and 41.7% did not. The majority (83.5%) of scans passed NDRL criteria [CTDIvol and DLP are set at 12 (mGy) and 430 (mGy·cm)], with higher pass rates for contrast (91.8%) versus non-contrast (81.5%) scans. Effective dose (ED) was compared before and after NDRL implementation. For non-contrast scans, ED declined 2.43% from 12.37±5.25 mSv to 12.07±4.99 mSv after implementation (non-significant, p>0.05). For contrast scans, ED declined more substantially, 6.77% from 9.6±4.61 mSv to 8.95±4.44 mSv (non-significant, p>0.05). The findings highlight higher NDRL compliance in procedures with contrast and show areas for dose optimization improvement in procedures without contrast. Results suggest NDRLs provide guidance for optimizing radiation dose, but other factors like patient characteristics, protocol settings, and quality assurance programs should also be considered to ensure doses are as low as reasonably achievable (ALARA) without compromising diagnostic quality. Regular monitoring and review of CT protocols is recommended to avoid unintended consequences of dose reduction. Continued optimization is encouraged to reduce dose while ensuring quality.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"26 3","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1051/radiopro/2024011","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
The management and optimization of radiation dose in computed tomography (CT) examinations is of paramount importance, especially when the safety of patients is concerned. This study evaluated the effect of implementing national diagnostic reference levels (NDRLs) for radiation dose optimization in 1,991 adult chest CT scans at a major Saudi hospital. Data was analyzed before and after NDRL implementation, with 21.5% of scans using contrast and 78.5% without. Before implementation, 11.1% used contrast and 36.7% did not; after implementation, 10.4% used contrast and 41.7% did not. The majority (83.5%) of scans passed NDRL criteria [CTDIvol and DLP are set at 12 (mGy) and 430 (mGy·cm)], with higher pass rates for contrast (91.8%) versus non-contrast (81.5%) scans. Effective dose (ED) was compared before and after NDRL implementation. For non-contrast scans, ED declined 2.43% from 12.37±5.25 mSv to 12.07±4.99 mSv after implementation (non-significant, p>0.05). For contrast scans, ED declined more substantially, 6.77% from 9.6±4.61 mSv to 8.95±4.44 mSv (non-significant, p>0.05). The findings highlight higher NDRL compliance in procedures with contrast and show areas for dose optimization improvement in procedures without contrast. Results suggest NDRLs provide guidance for optimizing radiation dose, but other factors like patient characteristics, protocol settings, and quality assurance programs should also be considered to ensure doses are as low as reasonably achievable (ALARA) without compromising diagnostic quality. Regular monitoring and review of CT protocols is recommended to avoid unintended consequences of dose reduction. Continued optimization is encouraged to reduce dose while ensuring quality.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.