Thermal runaway and induced electrical failure of epoxy resin in high-frequency transformers: Insulation design reference

IF 4.4 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC High Voltage Pub Date : 2024-03-11 DOI:10.1049/hve2.12424
Xingyu Shang, Lei Pang, Qinhao Bu, Qiaogen Zhang
{"title":"Thermal runaway and induced electrical failure of epoxy resin in high-frequency transformers: Insulation design reference","authors":"Xingyu Shang,&nbsp;Lei Pang,&nbsp;Qinhao Bu,&nbsp;Qiaogen Zhang","doi":"10.1049/hve2.12424","DOIUrl":null,"url":null,"abstract":"<p>Solid-state transformers (SSTs) have applications in medium-voltage direct current (MVDC) grids and compact power systems. High-frequency transformer (HFT) is the core component of SSTs. High levels of high frequency high d<i>v</i>/d<i>t</i> voltage stresses challenged the integrity of the galvanic insulation of HFTs. However, dielectric thermal runaway and resultant electrical failure mechanisms in epoxy resin (EP) cast insulation remain unclear. Dielectric heating of EP across varying voltages, frequencies, rising edges, duty cycles and DC biases were measured and corroborated by simulation. The thermal runaway threshold mainly depends on the tangency point of the loss generation and heat dissipation curves below the glass transition temperature. Observations reveal that thermal runaway does not directly cause breakdown; instead, thermal decomposition above 200°C triggers discharge and eventual failure. Simulations demonstrate that temperature rise mainly depends on the average field within the electrode region and inter-segment and inter-layer distances within the HFT winding definitively impact insulation thermal runaway. By applying different criteria for MV and high-voltage (HV) transformers, the reference electric fields for insulation design with unfilled and filled EP were obtained. For instance, limiting dielectric heating below 5 K at 50 kHz necessitates an RMS average field less than 0.44 V/mm, which is much lower than dry-type transformer conventions. The authors prove the necessity of re-evaluating the permissible field strength in HFT insulation design.</p>","PeriodicalId":48649,"journal":{"name":"High Voltage","volume":"9 5","pages":"989-1000"},"PeriodicalIF":4.4000,"publicationDate":"2024-03-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/hve2.12424","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Voltage","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/hve2.12424","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Solid-state transformers (SSTs) have applications in medium-voltage direct current (MVDC) grids and compact power systems. High-frequency transformer (HFT) is the core component of SSTs. High levels of high frequency high dv/dt voltage stresses challenged the integrity of the galvanic insulation of HFTs. However, dielectric thermal runaway and resultant electrical failure mechanisms in epoxy resin (EP) cast insulation remain unclear. Dielectric heating of EP across varying voltages, frequencies, rising edges, duty cycles and DC biases were measured and corroborated by simulation. The thermal runaway threshold mainly depends on the tangency point of the loss generation and heat dissipation curves below the glass transition temperature. Observations reveal that thermal runaway does not directly cause breakdown; instead, thermal decomposition above 200°C triggers discharge and eventual failure. Simulations demonstrate that temperature rise mainly depends on the average field within the electrode region and inter-segment and inter-layer distances within the HFT winding definitively impact insulation thermal runaway. By applying different criteria for MV and high-voltage (HV) transformers, the reference electric fields for insulation design with unfilled and filled EP were obtained. For instance, limiting dielectric heating below 5 K at 50 kHz necessitates an RMS average field less than 0.44 V/mm, which is much lower than dry-type transformer conventions. The authors prove the necessity of re-evaluating the permissible field strength in HFT insulation design.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高频变压器中环氧树脂的热失控和诱发电气故障:绝缘设计参考
固态变压器(SST)可应用于中压直流电网和紧凑型电力系统。高频变压器(HFT)是 SST 的核心部件。高频率、高 dv/dt 电压应力对高频变压器电偶绝缘的完整性提出了挑战。然而,环氧树脂(EP)浇铸绝缘的介电热失控和由此导致的电气故障机制仍不清楚。我们测量了环氧树脂在不同电压、频率、上升沿、占空比和直流偏压下的介电发热,并通过模拟进行了证实。热失控阈值主要取决于玻璃化温度以下的损耗产生曲线和散热曲线的切点。观察结果表明,热失控不会直接导致击穿;相反,超过 200°C 的热分解会引发放电并最终导致失效。模拟结果表明,温升主要取决于电极区域内的平均电场,而 HFT 绕组内的段间和层间距离对绝缘热失控有明确影响。通过对中压和高压(HV)变压器采用不同的标准,获得了未填充和填充 EP 绝缘设计的参考电场。例如,在 50 kHz 频率下将介质加热限制在 5 K 以下要求有效值平均电场小于 0.44 V/mm,这远远低于干式变压器的标准。作者证明有必要重新评估高频变压器绝缘设计中的允许场强。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
High Voltage
High Voltage Energy-Energy Engineering and Power Technology
CiteScore
9.60
自引率
27.30%
发文量
97
审稿时长
21 weeks
期刊介绍: High Voltage aims to attract original research papers and review articles. The scope covers high-voltage power engineering and high voltage applications, including experimental, computational (including simulation and modelling) and theoretical studies, which include: Electrical Insulation ● Outdoor, indoor, solid, liquid and gas insulation ● Transient voltages and overvoltage protection ● Nano-dielectrics and new insulation materials ● Condition monitoring and maintenance Discharge and plasmas, pulsed power ● Electrical discharge, plasma generation and applications ● Interactions of plasma with surfaces ● Pulsed power science and technology High-field effects ● Computation, measurements of Intensive Electromagnetic Field ● Electromagnetic compatibility ● Biomedical effects ● Environmental effects and protection High Voltage Engineering ● Design problems, testing and measuring techniques ● Equipment development and asset management ● Smart Grid, live line working ● AC/DC power electronics ● UHV power transmission Special Issues. Call for papers: Interface Charging Phenomena for Dielectric Materials - https://digital-library.theiet.org/files/HVE_CFP_ICP.pdf Emerging Materials For High Voltage Applications - https://digital-library.theiet.org/files/HVE_CFP_EMHVA.pdf
期刊最新文献
A novel thyristor-based hybrid DC circuit breaker with short arcing capability Fast evaluation on the fatigue level of copper contact wire based on laser induced breakdown spectroscopy and supervised machine learning for high speed railway Discharge image reconstruction and frequency domain analysis based on event data Differences in M-components between triggered lightning striking the ground and overhead line A novel embedded voltage-clamped circuit for multilevel modular converters submodule to suppress very fast transient overvoltage
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1