Improving Accuracy of In-The-Bag Intraocular Lens Power Calculation in Adult Eyes with Unilateral Subluxated Lenses by Using the Anterior Chamber Depth of the Unaffected Eye.
{"title":"Improving Accuracy of In-The-Bag Intraocular Lens Power Calculation in Adult Eyes with Unilateral Subluxated Lenses by Using the Anterior Chamber Depth of the Unaffected Eye.","authors":"Wei Lou, Ziang Chen, Yang Huang, Haiying Jin","doi":"10.1159/000538234","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses.</p><p><strong>Methods: </strong>The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method.</p><p><strong>Results: </strong>In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD.</p><p><strong>Conclusion: </strong>Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.</p>","PeriodicalId":19662,"journal":{"name":"Ophthalmic Research","volume":" ","pages":"248-256"},"PeriodicalIF":2.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000538234","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses.
Methods: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method.
Results: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD.
Conclusion: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.
期刊介绍:
''Ophthalmic Research'' features original papers and reviews reporting on translational and clinical studies. Authors from throughout the world cover research topics on every field in connection with physical, physiologic, pharmacological, biochemical and molecular biological aspects of ophthalmology. This journal also aims to provide a record of international clinical research for both researchers and clinicians in ophthalmology. Finally, the transfer of information from fundamental research to clinical research and clinical practice is particularly welcome.