A novel textile-based UWB patch antenna for breast cancer imaging.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL Physical and Engineering Sciences in Medicine Pub Date : 2024-09-01 Epub Date: 2024-03-26 DOI:10.1007/s13246-024-01409-w
Fawzia Abdien Ali Abdulla, Aşkin Demirkol
{"title":"A novel textile-based UWB patch antenna for breast cancer imaging.","authors":"Fawzia Abdien Ali Abdulla, Aşkin Demirkol","doi":"10.1007/s13246-024-01409-w","DOIUrl":null,"url":null,"abstract":"<p><p>Breast cancer is the second leading cause of death for women worldwide, and detecting cancer at an early stage increases the survival rate by 97%. In this study, a novel textile-based ultrawideband (UWB) microstrip patch antenna was designed and modeled to work in the 2-11.6 GHz frequency range and a simulation was used to test its performance in early breast cancer detection. The antenna was designed with an overall size of 31*31 mm <math><msup><mrow></mrow> <mn>2</mn></msup> </math> using a denim substrate and 100% metal polyamide-based fabric with copper, silver, and nickel to provide comfort for the wearer. The designed antenna was tested in four numerical breast models. The models ranged from simple tumor-free to complex models with small tumors. The size, structure, and position of the tumor were modified to test the suggested ability of the antenna to detect cancers with different shapes, sizes, and positions. The specific absorption rate (SAR), return loss (S11), and voltage standing wave ratio (VSWR) were calculated for each model to measure the antenna performance. The simulation results showed that SAR values were between 1.6 and 2 W/g (10 g SAR) and were within the allowed range for medical applications. Additionally, the VSWR remained in an acceptable range from 1.15 to 2. Depending on the size and location of the tumor, the antenna return losses of the four models ranged from <math><mo>-</mo></math> 36 to <math><mo>-</mo></math> 18.5 dB. The effect of bending was tested to determine the flexibility. The antenna proved to be highly effective and capable of detecting small tumors with diameters of up to 2 mm.</p>","PeriodicalId":48490,"journal":{"name":"Physical and Engineering Sciences in Medicine","volume":null,"pages":null},"PeriodicalIF":2.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11408408/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physical and Engineering Sciences in Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-024-01409-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Breast cancer is the second leading cause of death for women worldwide, and detecting cancer at an early stage increases the survival rate by 97%. In this study, a novel textile-based ultrawideband (UWB) microstrip patch antenna was designed and modeled to work in the 2-11.6 GHz frequency range and a simulation was used to test its performance in early breast cancer detection. The antenna was designed with an overall size of 31*31 mm 2 using a denim substrate and 100% metal polyamide-based fabric with copper, silver, and nickel to provide comfort for the wearer. The designed antenna was tested in four numerical breast models. The models ranged from simple tumor-free to complex models with small tumors. The size, structure, and position of the tumor were modified to test the suggested ability of the antenna to detect cancers with different shapes, sizes, and positions. The specific absorption rate (SAR), return loss (S11), and voltage standing wave ratio (VSWR) were calculated for each model to measure the antenna performance. The simulation results showed that SAR values were between 1.6 and 2 W/g (10 g SAR) and were within the allowed range for medical applications. Additionally, the VSWR remained in an acceptable range from 1.15 to 2. Depending on the size and location of the tumor, the antenna return losses of the four models ranged from - 36 to - 18.5 dB. The effect of bending was tested to determine the flexibility. The antenna proved to be highly effective and capable of detecting small tumors with diameters of up to 2 mm.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于乳腺癌成像的新型织物基 UWB 贴片天线。
乳腺癌是全球妇女的第二大死因,而早期发现癌症可将存活率提高 97%。本研究设计并模拟了一种新型纺织品超宽带(UWB)微带贴片天线,其工作频率范围为 2-11.6 GHz,并对其在早期乳腺癌检测中的性能进行了仿真测试。天线设计的整体尺寸为 31*31 mm 2,采用牛仔布基材和含铜、银和镍的 100% 金属聚酰胺基织物,为佩戴者提供舒适感。设计的天线在四个乳房模型中进行了测试。这些模型既有简单的无肿瘤模型,也有复杂的有小肿瘤的模型。对肿瘤的大小、结构和位置进行了修改,以测试天线检测不同形状、大小和位置的癌症的能力。计算了每个模型的比吸收率(SAR)、回波损耗(S11)和电压驻波比(VSWR),以衡量天线的性能。仿真结果表明,SAR 值介于 1.6 和 2 W/g 之间(10 g SAR),在医疗应用的允许范围内。此外,驻波比保持在 1.15 到 2 的可接受范围内。根据肿瘤的大小和位置,四个模型的天线回波损耗在 - 36 到 - 18.5 dB 之间。对弯曲的影响进行了测试,以确定其灵活性。事实证明,该天线非常有效,能够探测直径达 2 毫米的小肿瘤。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.40
自引率
4.50%
发文量
110
期刊最新文献
PET/CT-based 3D multi-class semantic segmentation of ovarian cancer and the stability of the extracted radiomics features. PPG2RespNet: a deep learning model for respirational signal synthesis and monitoring from photoplethysmography (PPG) signal Ecg signal watermarking using QR decomposition Effect of mirror system and scanner bed of a flatbed scanner on lateral response artefact in radiochromic film dosimetry A deep learning phase-based solution in 2D echocardiography motion estimation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1