{"title":"In vivo Assessment of a Manual Single Lumen Alternating Micro-Batch Hemodiafiltration System.","authors":"Sabrina L Lanker, Christopher J Pino, H David Humes, Lakhmir Chawla, Kimberly A Johnston","doi":"10.1159/000538358","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The manual single lumen alternating micro-batch hemodiafiltration (mSLAMB) system is a closed-loop dialysis system designed to provide kidney support in emergency situations (e.g., fluid overload, hyperkalemia, acidemia). If done repeatedly in small batches and at high flow rates, this system was found to achieve clearance levels comparable to traditional renal replacement therapy.</p><p><strong>Methods: </strong>Using a porcine model, uremic toxins and exogenous fluorescent tracer concentrations were successfully lowered within just 1 h of treatment.</p><p><strong>Results: </strong>With a maximal dialysate flow, mSLAMB can achieve decreases in serum potassium concentration of &gt;0.5 mmol/L/h. With the mSLAMB hemodiafiltration system, micro-batch processing was also successful in removing up to 250 mL of ultrafiltrate in 8 cycles.</p><p><strong>Conclusion: </strong>This process could create a better fluid balance allowing for administering therapeutic fluids such as sodium bicarbonate in the clinic. Electrolyte imbalance and volume overload remain severe life-threatening emergencies in low resource settings; therefore, mSLAMB should be explored further due to its modest vascular access requirements, low cost, and ability to be performed without electricity or batteries.</p>","PeriodicalId":8953,"journal":{"name":"Blood Purification","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Purification","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000538358","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The manual single lumen alternating micro-batch hemodiafiltration (mSLAMB) system is a closed-loop dialysis system designed to provide kidney support in emergency situations (e.g., fluid overload, hyperkalemia, acidemia). If done repeatedly in small batches and at high flow rates, this system was found to achieve clearance levels comparable to traditional renal replacement therapy.

Methods: Using a porcine model, uremic toxins and exogenous fluorescent tracer concentrations were successfully lowered within just 1 h of treatment.

Results: With a maximal dialysate flow, mSLAMB can achieve decreases in serum potassium concentration of >0.5 mmol/L/h. With the mSLAMB hemodiafiltration system, micro-batch processing was also successful in removing up to 250 mL of ultrafiltrate in 8 cycles.

Conclusion: This process could create a better fluid balance allowing for administering therapeutic fluids such as sodium bicarbonate in the clinic. Electrolyte imbalance and volume overload remain severe life-threatening emergencies in low resource settings; therefore, mSLAMB should be explored further due to its modest vascular access requirements, low cost, and ability to be performed without electricity or batteries.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
手动单腔交替微批次血液渗滤 (mSLAMB) 系统的体内评估。
简介:手动单腔交替微批次血液透析滤过(mSLAMB)系统是一种闭环透析系统,设计用于在紧急情况下(如液体超负荷、高钾血症、酸血症)提供肾脏支持。如果小批量、高流速地反复进行透析,该系统可达到与传统肾脏替代疗法(RRT)相当的清除水平:方法:使用猪模型,在治疗后 1 小时内成功降低了尿毒症毒素和外源性荧光示踪剂的浓度:结果:在最大透析流量下,mSLAMB 可使血清钾浓度下降 > 0.5 mmol/L/小时。使用 mSLAMB 血液透析过滤系统,微批处理也能在 8 个周期内成功去除多达 250 毫升的超滤液:结论:这一工艺可以改善体液平衡,从而在临床上使用治疗性液体,如碳酸氢钠。在资源匮乏的环境中,电解质失衡和容量超载仍然是严重威胁生命的紧急情况,因此,mSLAMB 因其对血管通路的要求不高、成本低廉以及无需电力或电池就能进行操作而值得进一步探索。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Blood Purification
Blood Purification 医学-泌尿学与肾脏学
CiteScore
5.80
自引率
3.30%
发文量
69
审稿时长
6-12 weeks
期刊介绍: Practical information on hemodialysis, hemofiltration, peritoneal dialysis and apheresis is featured in this journal. Recognizing the critical importance of equipment and procedures, particular emphasis has been placed on reports, drawn from a wide range of fields, describing technical advances and improvements in methodology. Papers reflect the search for cost-effective solutions which increase not only patient survival but also patient comfort and disease improvement through prevention or correction of undesirable effects. Advances in vascular access and blood anticoagulation, problems associated with exposure of blood to foreign surfaces and acute-care nephrology, including continuous therapies, also receive attention. Nephrologists, internists, intensivists and hospital staff involved in dialysis, apheresis and immunoadsorption for acute and chronic solid organ failure will find this journal useful and informative. ''Blood Purification'' also serves as a platform for multidisciplinary experiences involving nephrologists, cardiologists and critical care physicians in order to expand the level of interaction between different disciplines and specialities.
期刊最新文献
Effect of change in sodium after slow low-efficiency dialysis (SLED) in critically ill patients with acute kidney injury. Effect of dialysis on structural brain connectivity in patients with end-stage renal disease. A Pilot and Feasibility Study of Continuous Cardiac Output and Blood Pressure Monitoring during Intermittent Hemodialysis. Peripheral Blood Lymphocyte Subgroups in Patients Undergoing Hemodialysis with Medium Cut-Off Membranes and High-Flux Membranes: THE SHE Continuation Study. CaCl2-citrate regional anticoagulation with CVVHD leads to unwanted chloride loading compared to CVVH with systemic anticoagulation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1