{"title":"Optimization of Failure Modes of a Ductile Connection Under Fire Conditions","authors":"Yu Liu, Shan-Shan Huang, Ian Burgess, Bin Peng","doi":"10.1007/s10694-024-01571-3","DOIUrl":null,"url":null,"abstract":"<div><p>Connections are the most vulnerable parts of a structure under fire conditions. A novel steel connection with high axial and rotational ductility has been proposed with the objective to improve the performance of steel-framed buildings in fire. Analytical model has been developed to determine the axial displacement of the top and bottom flanges of the beam end at high temperatures. A series of sub-frame models with this ductile connection have been built using Abaqus to study the influence of the characteristics of the connection part between the fin-plate part and face-plate part on the overall connection behaviour. The current critical failure mode of the ductile connection is bolt pull-out from the face-plate zone, and the tensile deformation capacity of the connection is not fully utilized. Therefore, measures to improve the bolt pull-out failure mode of the connection have been tested using the Abaqus sub-frame models, including adding a strengthening plate to the face-plate part of the connection and increasing the connection plate thickness. The simulation results show that the bearing failure of the beam web will become another critical failure mode of the connection, once the bolt pull-out failure is eliminated. To further optimize the high-temperature performance of the connection, the Abaqus steel frame models have also been used to test some measures to delay the occurrence of the beam web bearing failure, including adding strengthening plates to the part of the beam web in contact with the connection, and improving the material properties of the part of the beam web around the bolt holes at high temperatures.</p></div>","PeriodicalId":558,"journal":{"name":"Fire Technology","volume":"60 4","pages":"2489 - 2511"},"PeriodicalIF":2.3000,"publicationDate":"2024-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Technology","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10694-024-01571-3","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Connections are the most vulnerable parts of a structure under fire conditions. A novel steel connection with high axial and rotational ductility has been proposed with the objective to improve the performance of steel-framed buildings in fire. Analytical model has been developed to determine the axial displacement of the top and bottom flanges of the beam end at high temperatures. A series of sub-frame models with this ductile connection have been built using Abaqus to study the influence of the characteristics of the connection part between the fin-plate part and face-plate part on the overall connection behaviour. The current critical failure mode of the ductile connection is bolt pull-out from the face-plate zone, and the tensile deformation capacity of the connection is not fully utilized. Therefore, measures to improve the bolt pull-out failure mode of the connection have been tested using the Abaqus sub-frame models, including adding a strengthening plate to the face-plate part of the connection and increasing the connection plate thickness. The simulation results show that the bearing failure of the beam web will become another critical failure mode of the connection, once the bolt pull-out failure is eliminated. To further optimize the high-temperature performance of the connection, the Abaqus steel frame models have also been used to test some measures to delay the occurrence of the beam web bearing failure, including adding strengthening plates to the part of the beam web in contact with the connection, and improving the material properties of the part of the beam web around the bolt holes at high temperatures.
期刊介绍:
Fire Technology publishes original contributions, both theoretical and empirical, that contribute to the solution of problems in fire safety science and engineering. It is the leading journal in the field, publishing applied research dealing with the full range of actual and potential fire hazards facing humans and the environment. It covers the entire domain of fire safety science and engineering problems relevant in industrial, operational, cultural, and environmental applications, including modeling, testing, detection, suppression, human behavior, wildfires, structures, and risk analysis.
The aim of Fire Technology is to push forward the frontiers of knowledge and technology by encouraging interdisciplinary communication of significant technical developments in fire protection and subjects of scientific interest to the fire protection community at large.
It is published in conjunction with the National Fire Protection Association (NFPA) and the Society of Fire Protection Engineers (SFPE). The mission of NFPA is to help save lives and reduce loss with information, knowledge, and passion. The mission of SFPE is advancing the science and practice of fire protection engineering internationally.