Shweta Singh, Vivek Ranjan, Padmaja Tripathy, M. N. Nachappa
{"title":"BALANCED LOAD FREQUENCY CONTROL: CUSTOMIZED WORLD CUP ALGORITHM - DRIVEN PID OPTIMIZATION FOR TWO AREA POWER SYSTEMS","authors":"Shweta Singh, Vivek Ranjan, Padmaja Tripathy, M. N. Nachappa","doi":"10.24874/pes.si.24.02.016","DOIUrl":null,"url":null,"abstract":"Finding a balance between the loads and generating demands in power systems is a significant challenge since power producers require important inputs such as security, reliability and quality. In this study, a unique method for balanced load frequency control (BLFC) is proposed in two-area power systems, integrating a customized World Cup Algorithm (CWCA)-Driven PID optimization. The primary objective is to enhance the stability and performance of power systems. For this purpose, the integral time-multiplied absolute error (ITAE) is minimized by evaluating the objective function using time-domain simulation. The proposed methodology aims to improve the overall response of the control system, ensuring a reliable and stable power supply. Within the scope of two-area power systems with BLFC, simulation results show the effectiveness and resilience of the CWCA-Driven PID Optimization. The outcomes of the proposed PID controller-based CWCA approach are contrasted with the existing methods.","PeriodicalId":33556,"journal":{"name":"Proceedings on Engineering Sciences","volume":" 15","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings on Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24874/pes.si.24.02.016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
Finding a balance between the loads and generating demands in power systems is a significant challenge since power producers require important inputs such as security, reliability and quality. In this study, a unique method for balanced load frequency control (BLFC) is proposed in two-area power systems, integrating a customized World Cup Algorithm (CWCA)-Driven PID optimization. The primary objective is to enhance the stability and performance of power systems. For this purpose, the integral time-multiplied absolute error (ITAE) is minimized by evaluating the objective function using time-domain simulation. The proposed methodology aims to improve the overall response of the control system, ensuring a reliable and stable power supply. Within the scope of two-area power systems with BLFC, simulation results show the effectiveness and resilience of the CWCA-Driven PID Optimization. The outcomes of the proposed PID controller-based CWCA approach are contrasted with the existing methods.