Characteristics of the reference X-ray narrow-spectrum series at SSDL of Institute for Nuclear Science and Technology

Thi My Linh Dang, Ngoc Quynh Nguyen, Duc-Ky Bui, Thi Nhung Duong, Quang Tuan Ho, Van Trieu Duong, Thanh Ha Tran, Thi Anh Duong Bui, Bao Ngoc Pham
{"title":"Characteristics of the reference X-ray narrow-spectrum series at SSDL of Institute for Nuclear Science and Technology","authors":"Thi My Linh Dang, Ngoc Quynh Nguyen, Duc-Ky Bui, Thi Nhung Duong, Quang Tuan Ho, Van Trieu Duong, Thanh Ha Tran, Thi Anh Duong Bui, Bao Ngoc Pham","doi":"10.53747/nst.v12i4.387","DOIUrl":null,"url":null,"abstract":"This paper presents the characteristics of the reference X-ray narrow-spectrum series used in the Secondary Standard Dosimetry Laboratory (SSDL) at Institute for Nuclear Science and Technology (INST) with X-ray beam irradiator. In order to perform calibration works, it is highly important to verify the characteristics and qualities of reference X-ray beam recommended by the International Standardization Organization (ISO) 4037:2019. The characteristics of the X-ray beams in terms of the half-value layer, homogeneity coefficient and the air kerma rate are determined for the narrow-spectrum series in the 40 and 150 keV range. The related dosimetric quantities such as the ambient dose equivalent and personal dose equivalent also determined. The experimental values are well consistent with the recommended values of the ISO 4037 criteria. It implies that the reference X-ray narrow-spectrum series (N-series) can be applied in calibration works of X-ray measuring devices used in radiation safety assessment.","PeriodicalId":19445,"journal":{"name":"Nuclear Science and Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53747/nst.v12i4.387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents the characteristics of the reference X-ray narrow-spectrum series used in the Secondary Standard Dosimetry Laboratory (SSDL) at Institute for Nuclear Science and Technology (INST) with X-ray beam irradiator. In order to perform calibration works, it is highly important to verify the characteristics and qualities of reference X-ray beam recommended by the International Standardization Organization (ISO) 4037:2019. The characteristics of the X-ray beams in terms of the half-value layer, homogeneity coefficient and the air kerma rate are determined for the narrow-spectrum series in the 40 and 150 keV range. The related dosimetric quantities such as the ambient dose equivalent and personal dose equivalent also determined. The experimental values are well consistent with the recommended values of the ISO 4037 criteria. It implies that the reference X-ray narrow-spectrum series (N-series) can be applied in calibration works of X-ray measuring devices used in radiation safety assessment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
核科学与技术研究所 SSDL 参考 X 射线窄谱系列的特征
本文介绍了核科学与技术研究所二级标准剂量测定实验室(SSDL)使用的 X 射线束辐照装置的参考 X 射线窄谱系列的特性。为了进行校准工作,验证国际标准化组织(ISO)4037:2019 推荐的参考 X 射线束的特性和质量非常重要。针对 40 和 150 千伏范围内的窄光谱系列,确定了 X 射线束在半值层、均匀性系数和空气开玛率方面的特性。同时还测定了相关的剂量测定量,如环境剂量当量和个人剂量当量。实验值与 ISO 4037 标准的推荐值完全一致。这意味着参考 X 射线窄谱系列(N 系列)可用于辐射安全评估中 X 射线测量设备的校准工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A study on the application of artificial neural network to predict k-eff and peaking factor of a small modular PWR Development of a Compact Digital Multichannel Analyzer based on FPGA Thermoluminescence characteristics of in-house synthesized K2GdF5:Tb powder for photon and neutron Study on the repeatability and reproducibility of low-level radioactivity measurements using the analysis of variance tool Evaluation and Comparison of AAA and AXB Dose Calculation Algorithms for Lung SBRT on TrueBeam STx with Eclipse 13.6
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1