{"title":"Rancang Bangun Alat Bantu Fiksasi Pemeriksaan Radiografi Lumbal Oblik","authors":"Agustina Dwi Prastanti, Haris Sulistiyadi, Halinda Fatmayanti","doi":"10.31983/jimed.v10i1.11076","DOIUrl":null,"url":null,"abstract":"Background: The oblique lumbar examination has been carried out. The position of object isn't object angle at 45° to the image receptor, but only estimate it. It caused not optimal image of scottie dog sign and spondylolysis (pressure in pars interarticularis). Therefore, an examination aid is needed to make it easier to obtain the position of the oblique lumbar object.Methods: This research design is a RnD study with the ADDIE model which is carried out with five stages, namely analysis, design, development, implementation, and evaluation. The data is carried out by observing, designing, testing, and analyzing whether there are artifacts.Results: An oblique lumbar radiographic examination fixation aid was produced from acrylic material with a thickness of 5 mm. Acrylic is shaped like a right-angled triangular prism building which has a longer base measuring 50 cm, width 42 cm, and height 25 cm. A rectangular base with a length of 50 cm is pressed against the patient's body so that the supporting part of the angled triangle that supports the patient's lumbar region or the patient's body does not shift during an oblique lumbar radiography examination. This tool has a mass dimension of 2.5kg.Conclusion: The design of the oblique lumbar radiographic examination fixation tool resembles a right-angled triangular prism with one side tilted at a 45 degree angle to adjust the position of the object so that it can obtain a good view of the Scottie dog sign to show part of the pars interarticularis.","PeriodicalId":205622,"journal":{"name":"Jurnal Imejing Diagnostik (JImeD)","volume":"456 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Imejing Diagnostik (JImeD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/jimed.v10i1.11076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The oblique lumbar examination has been carried out. The position of object isn't object angle at 45° to the image receptor, but only estimate it. It caused not optimal image of scottie dog sign and spondylolysis (pressure in pars interarticularis). Therefore, an examination aid is needed to make it easier to obtain the position of the oblique lumbar object.Methods: This research design is a RnD study with the ADDIE model which is carried out with five stages, namely analysis, design, development, implementation, and evaluation. The data is carried out by observing, designing, testing, and analyzing whether there are artifacts.Results: An oblique lumbar radiographic examination fixation aid was produced from acrylic material with a thickness of 5 mm. Acrylic is shaped like a right-angled triangular prism building which has a longer base measuring 50 cm, width 42 cm, and height 25 cm. A rectangular base with a length of 50 cm is pressed against the patient's body so that the supporting part of the angled triangle that supports the patient's lumbar region or the patient's body does not shift during an oblique lumbar radiography examination. This tool has a mass dimension of 2.5kg.Conclusion: The design of the oblique lumbar radiographic examination fixation tool resembles a right-angled triangular prism with one side tilted at a 45 degree angle to adjust the position of the object so that it can obtain a good view of the Scottie dog sign to show part of the pars interarticularis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
设计斜位腰椎 X 射线检查固定辅助工具
背景介绍腰椎斜位检查已经开展。物体的位置不是与图像接收器成 45°,而只是估计。这造成了斯科蒂狗征和脊柱溶解症(关节旁受压)的图像不理想。因此,需要一种检查辅助工具,以便更容易获得斜腰椎物体的位置:本研究设计是一项采用 ADDIE 模型的研发研究,分为五个阶段,即分析、设计、开发、实施和评估。通过观察、设计、测试和分析是否存在人工痕迹来获得数据:结果:用厚度为 5 毫米的丙烯酸材料制作了一种斜腰椎放射检查固定辅助工具。丙烯酸树脂的形状像一个直角三角形棱柱,它的底座较长,长 50 厘米,宽 42 厘米,高 25 厘米。长 50 厘米的矩形底座压在患者身体上,这样在进行腰部斜位射线照相检查时,支撑患者腰部或患者身体的斜角三角形支撑部分就不会移动。该工具的质量为 2.5 千克:腰椎斜位X线摄影检查固定工具的设计类似于一个直角三角形棱镜,一侧倾斜 45 度角以调整物体的位置,从而获得良好的苏格兰狗征视野,显示部分关节旁。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluasi Pemeriksaan MRI Brain dengan Klinis Vertigo di Rumah Sakit Otak dr. Drs. M. Hatta Bukittinggi Implementasi Pemanfaatan Sumber Radiasi Pengion pada Ruang CT Scan ditinjau berdasarkan Peraturan BAPETEN No. 4 tahun 2020 di Instalasi Radiologi Rumah Sakit type B di Wilayah Kabupaten Sumedang Nilai Entrance Skin Dose Tiroid antara menggunakan Thyroid Shield dan tanpa Thyroid Shield pada Pemeriksaan CT Scan Kepala Analisis Informasi Anatomi Pemeriksaan MRI Ankle Joint pada Penggunaan Foot Ankle Coil dan Flex Coil Proton Density Fat Saturation Irisan Sagital Evaluasi Kualitas Radiograf Periapikal Teknik Bisektris : Kesalahan Penempatan Sudut Penyinaran dan Film
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1