Audit Dan Peluang Penghematan Energi Listrik CV Tirta Windu Agung 3 Probolinggo

Rohmanita Duanaputri, Muhammad Fahmi Hakim, Ahmad Jamaruddin, Tresna Umar Syamsuri
{"title":"Audit Dan Peluang Penghematan Energi Listrik CV Tirta Windu Agung 3 Probolinggo","authors":"Rohmanita Duanaputri, Muhammad Fahmi Hakim, Ahmad Jamaruddin, Tresna Umar Syamsuri","doi":"10.33795/elposys.v11i1.4875","DOIUrl":null,"url":null,"abstract":"The use of electrical energy in the building and industrial sectors is very important, especially the use and allocation of funds spent is quite large. So it is necessary to use energy as efficiently as possible. So there is a need for an energy audit to determine the level of electrical energy consumption used, where the results will be compared with predetermined standards. This research was carried out at CV Tirta Windu Agung 3 using a PM5100 and lux meter. From initial audit calculations, the IKE value was found to be 13.42 kWh/m2/year. This IKE value is the total of the buildings and ponds. The IKE value still includes very efficient criteria. Based on the results of detailed audit calculations, the value obtained before improvement was 2.23 kWh/m2/year. The IKE value still includes the criteria for being very efficient or meeting standards. After improvements it became 1.65 kWh/m2/year. Energy saving opportunities are available in indoor and outdoor lighting systems by replacing CFL (compact fluorescent lamp) lamps with Philips LED lamps. Based on calculations, the savings in electrical energy costs are IDR 41,736/day, resulting in savings of IDR 15,233,640/year. Based on the Isc/IL calculation above, it can be seen that the Isc/IL value is 165.4. According to the IEEE 519-2014 standard, the ISC IL value in the range >1000 has a permissible THDi value limit of 15%. The nominal voltage used is 0.4 kV, so the permitted THDv is 8%. Based on table 3.9 THDv and THDi under standard conditions.","PeriodicalId":476257,"journal":{"name":"Elposys: Jurnal Sistem Kelistrikan","volume":"263 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Elposys: Jurnal Sistem Kelistrikan","FirstCategoryId":"0","ListUrlMain":"https://doi.org/10.33795/elposys.v11i1.4875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The use of electrical energy in the building and industrial sectors is very important, especially the use and allocation of funds spent is quite large. So it is necessary to use energy as efficiently as possible. So there is a need for an energy audit to determine the level of electrical energy consumption used, where the results will be compared with predetermined standards. This research was carried out at CV Tirta Windu Agung 3 using a PM5100 and lux meter. From initial audit calculations, the IKE value was found to be 13.42 kWh/m2/year. This IKE value is the total of the buildings and ponds. The IKE value still includes very efficient criteria. Based on the results of detailed audit calculations, the value obtained before improvement was 2.23 kWh/m2/year. The IKE value still includes the criteria for being very efficient or meeting standards. After improvements it became 1.65 kWh/m2/year. Energy saving opportunities are available in indoor and outdoor lighting systems by replacing CFL (compact fluorescent lamp) lamps with Philips LED lamps. Based on calculations, the savings in electrical energy costs are IDR 41,736/day, resulting in savings of IDR 15,233,640/year. Based on the Isc/IL calculation above, it can be seen that the Isc/IL value is 165.4. According to the IEEE 519-2014 standard, the ISC IL value in the range >1000 has a permissible THDi value limit of 15%. The nominal voltage used is 0.4 kV, so the permitted THDv is 8%. Based on table 3.9 THDv and THDi under standard conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
审计和节约电能的机会 CV Tirta Windu Agung 3 Probolinggo
电能在建筑和工业部门的使用非常重要,尤其是使用和分配所花费的资金相当大。因此,有必要尽可能高效地使用能源。因此,有必要进行能源审计,以确定所使用的电能消耗水平,并将审计结果与预定标准进行比较。这项研究是在 CV Tirta Windu Agung 3 使用 PM5100 和照度计进行的。根据初步审计计算,IKE 值为 13.42 千瓦时/平方米/年。这个 IKE 值是建筑物和池塘的总和。该 IKE 值仍包括非常高效的标准。根据详细的审计计算结果,改进前的值为 2.23 千瓦时/平方米/年。IKE 值仍包括非常高效或达标标准。改进后,该值变为 1.65 千瓦时/平方米/年。用飞利浦 LED 灯取代 CFL(紧凑型荧光灯),室内和室外照明系统都有节能机会。根据计算,每天可节约电能成本 41 736 印尼盾,每年可节约 15 233 640 印尼盾。根据上述 Isc/IL 计算结果,可以看出 Isc/IL 值为 165.4。根据 IEEE 519-2014 标准,ISC IL 值在大于 1000 的范围内,允许的 THDi 值限制为 15%。使用的额定电压为 0.4 kV,因此允许的 THDv 为 8%。根据表 3.9 标准条件下的 THDv 和 THDi。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Studi Ekonomis Implementasi Kapasitor Dengan Detuned Reactor Untuk Meningkatkan Efisiensi Faktor Daya Desain Pembangkit Listrik Tenaga Surya Off-Grid dan Monitoring Berbasis Node-Red Rancang Bangun Thermoelectric Generator (TEG) Sebagai Suplai Daya Alternatif Germinasi Kacang Hijau Implementasi Sistem Monitoring Alat Pengering Biji Kopi Berbasis IoT (Internet of Things) Rancang Bangun Akuarium Dengan Pengkondisian PH Air Otomatis Berbasis PLTS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1