Karakterisasi Bolus Berbahan Campuran Beeswax dan Petroleum Jelly Menggunakan Berkas Elektron Pada Energi 6 MeV dan 9 MeV

Rico Adrial
{"title":"Karakterisasi Bolus Berbahan Campuran Beeswax dan Petroleum Jelly Menggunakan Berkas Elektron Pada Energi 6 MeV dan 9 MeV","authors":"Rico Adrial","doi":"10.23960/jtaf.v12i1.3205","DOIUrl":null,"url":null,"abstract":"In radiotherapy cases of cancer on the surface of the skin generally use electron beams. The electron beam has not been able to provide the optimum surface radiation dose. Therefore, a material that is able to increase the dose of surface radiation is needed, which is called a bolus. This study tested a bolus made from a mixture of beeswax and petroleum jelly. The bolus test includes the determination of density, the value of Relative Electron Density (RED) and the determination of the absorbed dose. The absorbed dose value was obtained by irradiating using a Linear Accelerator (LINAC) at 6 MeV and 9 MeV energies. The RED value was obtained from the bolus tomography image using a CT-simulator by determining the Region of Interest (ROI). The bolus density values obtained from physical measurements using the TPS program have almost the same average density values. The RED bolus value obtained at a thickness of 0.2 cm to 0.8 cm has a lower RED value than the RED value of the breast, which is 0.976. However, at 1.0 cm thickness, the RED value is equivalent to breast tissue. The value of the absorbed dose in a bolus made from a mixture of beeswax and petroleum jelly, the thicker the bolus used, the smaller the increase in the absorbed dose. The results of this study indicate that a bolus made from a mixture of beeswax and petroleum jelly can be the choice of bolus material during radiotherapy.","PeriodicalId":314761,"journal":{"name":"Jurnal Teori dan Aplikasi Fisika","volume":"4 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teori dan Aplikasi Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23960/jtaf.v12i1.3205","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In radiotherapy cases of cancer on the surface of the skin generally use electron beams. The electron beam has not been able to provide the optimum surface radiation dose. Therefore, a material that is able to increase the dose of surface radiation is needed, which is called a bolus. This study tested a bolus made from a mixture of beeswax and petroleum jelly. The bolus test includes the determination of density, the value of Relative Electron Density (RED) and the determination of the absorbed dose. The absorbed dose value was obtained by irradiating using a Linear Accelerator (LINAC) at 6 MeV and 9 MeV energies. The RED value was obtained from the bolus tomography image using a CT-simulator by determining the Region of Interest (ROI). The bolus density values obtained from physical measurements using the TPS program have almost the same average density values. The RED bolus value obtained at a thickness of 0.2 cm to 0.8 cm has a lower RED value than the RED value of the breast, which is 0.976. However, at 1.0 cm thickness, the RED value is equivalent to breast tissue. The value of the absorbed dose in a bolus made from a mixture of beeswax and petroleum jelly, the thicker the bolus used, the smaller the increase in the absorbed dose. The results of this study indicate that a bolus made from a mixture of beeswax and petroleum jelly can be the choice of bolus material during radiotherapy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在 6 兆电子伏特和 9 兆电子伏特能量下使用电子束分析蜂蜡和凡士林混合物制成的玻流体的特性
在皮肤表面癌症的放射治疗中,一般使用电子束。电子束无法提供最佳的表面辐射剂量。因此,需要一种能够增加表面辐射剂量的材料,这就是栓剂。这项研究测试了一种由蜂蜡和凡士林混合制成的栓剂。栓剂测试包括密度、相对电子密度(RED)值和吸收剂量的测定。吸收剂量值是通过使用线性加速器(LINAC)在 6 MeV 和 9 MeV 能量下进行辐照获得的。RED值是通过确定感兴趣区(ROI),使用CT模拟器从栓塞断层扫描图像中获得的。使用 TPS 程序通过物理测量获得的栓子密度值与平均密度值几乎相同。厚度为 0.2 厘米至 0.8 厘米时获得的 RED 药丸值比乳房的 RED 值(0.976)要低。然而,在厚度为 1.0 厘米时,RED 值与乳腺组织相当。从蜂蜡和凡士林混合物制成的栓剂的吸收剂量值来看,使用的栓剂越厚,吸收剂量的增幅越小。研究结果表明,放疗时可以选择蜂蜡和凡士林的混合物作为栓剂材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Rancang Bangun Alat Ukur Tingkat Manis Buah Jeruk Menggunakan Sensor Kapasitor Semi Silinder Berbasis Arduino Analisis Pengaruh Ukuran Lantai Muatan Timbangan Terhadap Nilai Error Pada Pengujian Eksentrisitas Timbangan Elektronik Sesuai OIML R76 Dynamic Viscosity Measurement Method Based on the Stokes Drag of Prolate Ellipsoidal Mass Analisis Kuantum pada Rangkaian LC dengan Pendekatan Fungsi Gelombang Radial Persamaan Schrȍdinger Potensial Osilator Harmonik Electric Field Controlled Anisotropic Rashba Splitting in Janus Chromium Dichalcogenide Monolayers : A Computational Study based on Density Functional Theory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1