Enrico Roma , Antoine Michel , Romain Tourillon , Guillaume Y. Millet , Jean-Benoît Morin
{"title":"Reliability and measurement error of a maximal voluntary toe plantarflexion measurement process","authors":"Enrico Roma , Antoine Michel , Romain Tourillon , Guillaume Y. Millet , Jean-Benoît Morin","doi":"10.1016/j.foot.2024.102095","DOIUrl":null,"url":null,"abstract":"<div><p>Despite the growing interest, information regarding the psychometric properties of maximal voluntary isometric toe plantarflexion force and rate of force development (RFD) is lacking. Hence, we investigate the test-retest reliability and measurement error of these outcome measurement instruments measured with a custom-built dynamometer. Twenty-six healthy adults participated in a crossed design with four sessions separated by 5–7 days. RFD was quantified using manual onset and calculating the impulse and the slope in the following time windows: 0–50 ms, 0–100 ms, 0–150 ms, 0–200 ms, 0–250 ms. We estimated the systematic bias of the mean, the intraclass correlation coefficient (ICC) and standard error of measurement (SEM) from the agreement and consistency models. The ICC and the SEM agreement for maximal voluntary isometric toe plantarflexion force along the perpendicular axis were respectively 0.87 (95%CI: 0.76, 0.93) and 27 N (22, 32), while along the resultant of the perpendicular and anterior posterior axis they were 0.85 (0.73, 0.92) and 29 N (23, 35). The results of the consistency model were similar as the estimated variance for session was closer to zero. A systematic bias of the mean between session 1 and 3 was found. For the RFD variables, the ICC agreement ranged from 0.35 to 0.65. The measurement process was found to be reliable to assess maximal voluntary isometric toe plantarflexion force but not RFD. However, a familiarization session is mandatory and these results need to be confirmed in less coordinated (e.g. aging population) individuals.</p></div>","PeriodicalId":12349,"journal":{"name":"Foot","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0958259224000282/pdfft?md5=e26ac8e3722ed685a93a11514153e8be&pid=1-s2.0-S0958259224000282-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0958259224000282","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
Abstract
Despite the growing interest, information regarding the psychometric properties of maximal voluntary isometric toe plantarflexion force and rate of force development (RFD) is lacking. Hence, we investigate the test-retest reliability and measurement error of these outcome measurement instruments measured with a custom-built dynamometer. Twenty-six healthy adults participated in a crossed design with four sessions separated by 5–7 days. RFD was quantified using manual onset and calculating the impulse and the slope in the following time windows: 0–50 ms, 0–100 ms, 0–150 ms, 0–200 ms, 0–250 ms. We estimated the systematic bias of the mean, the intraclass correlation coefficient (ICC) and standard error of measurement (SEM) from the agreement and consistency models. The ICC and the SEM agreement for maximal voluntary isometric toe plantarflexion force along the perpendicular axis were respectively 0.87 (95%CI: 0.76, 0.93) and 27 N (22, 32), while along the resultant of the perpendicular and anterior posterior axis they were 0.85 (0.73, 0.92) and 29 N (23, 35). The results of the consistency model were similar as the estimated variance for session was closer to zero. A systematic bias of the mean between session 1 and 3 was found. For the RFD variables, the ICC agreement ranged from 0.35 to 0.65. The measurement process was found to be reliable to assess maximal voluntary isometric toe plantarflexion force but not RFD. However, a familiarization session is mandatory and these results need to be confirmed in less coordinated (e.g. aging population) individuals.
期刊介绍:
The Foot is an international peer-reviewed journal covering all aspects of scientific approaches and medical and surgical treatment of the foot. The Foot aims to provide a multidisciplinary platform for all specialties involved in treating disorders of the foot. At present it is the only journal which provides this inter-disciplinary opportunity. Primary research papers cover a wide range of disorders of the foot and their treatment, including diabetes, vascular disease, neurological, dermatological and infectious conditions, sports injuries, biomechanics, bioengineering, orthoses and prostheses.