Reliability and measurement error of a maximal voluntary toe plantarflexion measurement process

Q2 Health Professions Foot Pub Date : 2024-04-03 DOI:10.1016/j.foot.2024.102095
Enrico Roma , Antoine Michel , Romain Tourillon , Guillaume Y. Millet , Jean-Benoît Morin
{"title":"Reliability and measurement error of a maximal voluntary toe plantarflexion measurement process","authors":"Enrico Roma ,&nbsp;Antoine Michel ,&nbsp;Romain Tourillon ,&nbsp;Guillaume Y. Millet ,&nbsp;Jean-Benoît Morin","doi":"10.1016/j.foot.2024.102095","DOIUrl":null,"url":null,"abstract":"<div><p>Despite the growing interest, information regarding the psychometric properties of maximal voluntary isometric toe plantarflexion force and rate of force development (RFD) is lacking. Hence, we investigate the test-retest reliability and measurement error of these outcome measurement instruments measured with a custom-built dynamometer. Twenty-six healthy adults participated in a crossed design with four sessions separated by 5–7 days. RFD was quantified using manual onset and calculating the impulse and the slope in the following time windows: 0–50 ms, 0–100 ms, 0–150 ms, 0–200 ms, 0–250 ms. We estimated the systematic bias of the mean, the intraclass correlation coefficient (ICC) and standard error of measurement (SEM) from the agreement and consistency models. The ICC and the SEM agreement for maximal voluntary isometric toe plantarflexion force along the perpendicular axis were respectively 0.87 (95%CI: 0.76, 0.93) and 27 N (22, 32), while along the resultant of the perpendicular and anterior posterior axis they were 0.85 (0.73, 0.92) and 29 N (23, 35). The results of the consistency model were similar as the estimated variance for session was closer to zero. A systematic bias of the mean between session 1 and 3 was found. For the RFD variables, the ICC agreement ranged from 0.35 to 0.65. The measurement process was found to be reliable to assess maximal voluntary isometric toe plantarflexion force but not RFD. However, a familiarization session is mandatory and these results need to be confirmed in less coordinated (e.g. aging population) individuals.</p></div>","PeriodicalId":12349,"journal":{"name":"Foot","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0958259224000282/pdfft?md5=e26ac8e3722ed685a93a11514153e8be&pid=1-s2.0-S0958259224000282-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0958259224000282","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Despite the growing interest, information regarding the psychometric properties of maximal voluntary isometric toe plantarflexion force and rate of force development (RFD) is lacking. Hence, we investigate the test-retest reliability and measurement error of these outcome measurement instruments measured with a custom-built dynamometer. Twenty-six healthy adults participated in a crossed design with four sessions separated by 5–7 days. RFD was quantified using manual onset and calculating the impulse and the slope in the following time windows: 0–50 ms, 0–100 ms, 0–150 ms, 0–200 ms, 0–250 ms. We estimated the systematic bias of the mean, the intraclass correlation coefficient (ICC) and standard error of measurement (SEM) from the agreement and consistency models. The ICC and the SEM agreement for maximal voluntary isometric toe plantarflexion force along the perpendicular axis were respectively 0.87 (95%CI: 0.76, 0.93) and 27 N (22, 32), while along the resultant of the perpendicular and anterior posterior axis they were 0.85 (0.73, 0.92) and 29 N (23, 35). The results of the consistency model were similar as the estimated variance for session was closer to zero. A systematic bias of the mean between session 1 and 3 was found. For the RFD variables, the ICC agreement ranged from 0.35 to 0.65. The measurement process was found to be reliable to assess maximal voluntary isometric toe plantarflexion force but not RFD. However, a familiarization session is mandatory and these results need to be confirmed in less coordinated (e.g. aging population) individuals.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脚趾最大自主跖屈测量过程的可靠性和测量误差
尽管人们的兴趣与日俱增,但有关最大自愿等长脚趾跖屈力和力量发展速度(RFD)的心理测量特性的信息却很缺乏。因此,我们研究了使用定制测力计测量这些结果测量工具的重复测试可靠性和测量误差。26 名健康成年人参加了交叉设计的四次训练,每次训练间隔 5-7 天。RFD 采用手动起始,并计算以下时间窗口中的脉冲和斜率进行量化:0-50毫秒、0-100毫秒、0-150毫秒、0-200毫秒、0-250毫秒。我们通过一致性和一致性模型估算了平均值的系统偏差、类内相关系数(ICC)和测量标准误差(SEM)。沿垂直轴的最大自主等长趾跖屈力的 ICC 和 SEM 一致性分别为 0.87(95%CI:0.76,0.93)和 27 N(22,32),而沿垂直轴和前后轴的结果则分别为 0.85(0.73,0.92)和 29 N(23,35)。一致性模型的结果与此类似,因为估计的节段方差更接近于零。结果发现,第 1 次和第 3 次的平均值存在系统性偏差。对于 RFD 变量,ICC 一致度介于 0.35 和 0.65 之间。结果表明,测量过程在评估最大自主等长足趾跖屈力方面是可靠的,但在评估射频分配方面并不可靠。然而,熟悉测量过程是必须的,而且这些结果还需要在协调性较差(如老龄人口)的个体中得到证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Foot
Foot Health Professions-Podiatry
CiteScore
2.00
自引率
0.00%
发文量
37
期刊介绍: The Foot is an international peer-reviewed journal covering all aspects of scientific approaches and medical and surgical treatment of the foot. The Foot aims to provide a multidisciplinary platform for all specialties involved in treating disorders of the foot. At present it is the only journal which provides this inter-disciplinary opportunity. Primary research papers cover a wide range of disorders of the foot and their treatment, including diabetes, vascular disease, neurological, dermatological and infectious conditions, sports injuries, biomechanics, bioengineering, orthoses and prostheses.
期刊最新文献
The effectiveness of custom hard-shell 3D-printed foot orthoses in a cohort of patients who did not respond to treatment with custom ethylene-vinyl-acetate (EVA) foot orthoses Regional changes in the free Achilles tendon volume in response to repeated submaximal contractions Mechanical drivers of intrinsic foot muscle for maximum toe flexor strength in upright standing across different body size Accuracy and reliability of the Ipswich touch test in identifying loss of protective sensation among diabetic patients Predictors of poor pre-operative patient reported outcome measures in elective foot and ankle surgery: Analysis of 1217 patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1