Indoor air quality and sick building syndrome symptoms in administrative office at public university

Amalina Abu Mansor , Samsuri Abdullah , Aimi Nursyahirah Ahmad , Ali Najah Ahmed , Mohammad Fakhratul Ridwan Zulkifli , Suriani Mat Jusoh , Marzuki Ismail
{"title":"Indoor air quality and sick building syndrome symptoms in administrative office at public university","authors":"Amalina Abu Mansor ,&nbsp;Samsuri Abdullah ,&nbsp;Aimi Nursyahirah Ahmad ,&nbsp;Ali Najah Ahmed ,&nbsp;Mohammad Fakhratul Ridwan Zulkifli ,&nbsp;Suriani Mat Jusoh ,&nbsp;Marzuki Ismail","doi":"10.1016/j.dialog.2024.100178","DOIUrl":null,"url":null,"abstract":"<div><p>Sick Building Syndrome (SBS) is an illness among workers linked to time spent in a building. This study aimed to investigate the Indoor Air Quality (IAQ) and symptoms of Sick Building Syndrome (SBS) among administrative office workers. The IAQ parameters consist of ventilation performance indicators, and physical and chemical parameters were measured using specified instruments for three days during weekdays. The SBS symptoms were assessed by a questionnaire adopted from the Industry Code of Practice of Indoor Air Quality (ICOP-IAQ) 2010 among 19 employees from the office in East Coast Malaysia. Relationship between past symptoms and present symptoms which are draught (past symptoms) with feeling heavy headed (present symptoms) (<em>r</em> = 0.559, <em>p</em> &lt; 0.05), room temperature too high (past symptoms) was highly correlated with feeling heavy headed (present symptoms) (<em>r</em> = 0.598, <em>p</em> &lt; 0.01) and cough (present symptoms) (<em>r</em> = 0.596, p &lt; 0.01). Room temperature (past symptoms) has a positive medium relationship with cough (present symptoms) (<em>r</em> = 0.477, <em>p</em> &lt; 0.05) and scaling itching scalp or ears (present symptoms) has a relationship between stuffy bad air (<em>r</em> = 0.475, <em>p</em> &lt; 0.05) and dry air (<em>r</em> = 0.536, p &lt; 0.05). There was a significant association between RH with drowsiness (χ2 = 7.090, <em>p</em> = 0.049) and dizziness (χ2 = 7.090, p = 0.049). The association was found between temperature and SBS symptoms between temperature with headache (χ2 = 7.574, <em>p</em> = 0.051), feeling heavy-headed (χ2 = 8.090, <em>p</em> = 0.046), and skin rash itchiness (χ2 = 7.451, <em>p</em> = 0.044). Air movement also showed a positive association with symptoms of feeling heavy-headed (x2 = 8.726, <em>p</em> = 0.021). PM<sub>10</sub> has positive significance with SBSS which are feeling heavy-headed (χ2 = 7.980, <em>p</em> = 0.023), and eyer's irritation (χ2 = 7.419, <em>p</em> = 0.038). The conclusion of this study showed that there were positive significant between temperature and relative humidity toward SBSS.</p></div>","PeriodicalId":72803,"journal":{"name":"Dialogues in health","volume":"4 ","pages":"Article 100178"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772653324000145/pdfft?md5=eeb7fd6e1761a34032fd701ab051a0d0&pid=1-s2.0-S2772653324000145-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dialogues in health","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772653324000145","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Sick Building Syndrome (SBS) is an illness among workers linked to time spent in a building. This study aimed to investigate the Indoor Air Quality (IAQ) and symptoms of Sick Building Syndrome (SBS) among administrative office workers. The IAQ parameters consist of ventilation performance indicators, and physical and chemical parameters were measured using specified instruments for three days during weekdays. The SBS symptoms were assessed by a questionnaire adopted from the Industry Code of Practice of Indoor Air Quality (ICOP-IAQ) 2010 among 19 employees from the office in East Coast Malaysia. Relationship between past symptoms and present symptoms which are draught (past symptoms) with feeling heavy headed (present symptoms) (r = 0.559, p < 0.05), room temperature too high (past symptoms) was highly correlated with feeling heavy headed (present symptoms) (r = 0.598, p < 0.01) and cough (present symptoms) (r = 0.596, p < 0.01). Room temperature (past symptoms) has a positive medium relationship with cough (present symptoms) (r = 0.477, p < 0.05) and scaling itching scalp or ears (present symptoms) has a relationship between stuffy bad air (r = 0.475, p < 0.05) and dry air (r = 0.536, p < 0.05). There was a significant association between RH with drowsiness (χ2 = 7.090, p = 0.049) and dizziness (χ2 = 7.090, p = 0.049). The association was found between temperature and SBS symptoms between temperature with headache (χ2 = 7.574, p = 0.051), feeling heavy-headed (χ2 = 8.090, p = 0.046), and skin rash itchiness (χ2 = 7.451, p = 0.044). Air movement also showed a positive association with symptoms of feeling heavy-headed (x2 = 8.726, p = 0.021). PM10 has positive significance with SBSS which are feeling heavy-headed (χ2 = 7.980, p = 0.023), and eyer's irritation (χ2 = 7.419, p = 0.038). The conclusion of this study showed that there were positive significant between temperature and relative humidity toward SBSS.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
公立大学行政办公室的室内空气质量和病态楼宇综合征症状
病态楼宇综合症(SBS)是一种与在楼宇内工作时间有关的工人疾病。本研究旨在调查行政办公人员的室内空气质量(IAQ)和病态楼宇综合症(SBS)症状。室内空气质量参数包括通风性能指标、物理和化学参数,使用指定仪器在工作日测量三天。通过采用 2010 年《室内空气质量行业规范》(ICOP-IAQ)的调查问卷,对马来西亚东海岸办公室的 19 名员工进行了 SBS 症状评估。过去的症状与现在的症状之间的关系是:气流(过去的症状)与头重脚轻(现在的症状)(r = 0.559,p < 0.05)、室温过高(过去的症状)与头重脚轻(现在的症状)(r = 0.598,p < 0.01)和咳嗽(现在的症状)(r = 0.596,p < 0.01)。室温(过去的症状)与咳嗽(现在的症状)呈中性正相关(r = 0.477,p < 0.05),头皮或耳朵瘙痒(现在的症状)与空气闷热(r = 0.475,p < 0.05)和空气干燥(r = 0.536,p < 0.05)呈中性正相关。相对湿度与嗜睡(χ2 = 7.090,p = 0.049)和头晕(χ2 = 7.090,p = 0.049)之间存在明显关联。温度与 SBS 症状之间存在关联,温度与头痛(χ2 = 7.574,P = 0.051)、头重脚轻(χ2 = 8.090,P = 0.046)和皮疹瘙痒(χ2 = 7.451,P = 0.044)之间存在关联。空气流动也与头重脚轻症状呈正相关(x2 = 8.726,p = 0.021)。PM10 与头重脚轻(χ2 = 7.980,p = 0.023)和眼睛不适(χ2 = 7.419,p = 0.038)的 SBSS 呈正相关。本研究的结论表明,温度和相对湿度对 SBSS 的影响呈正相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Dialogues in health
Dialogues in health Public Health and Health Policy
CiteScore
0.70
自引率
0.00%
发文量
0
审稿时长
134 days
期刊最新文献
Fishing with skis, digging with noodles: Resolving task-and-tool mismatches in efforts to advance health equity Blurred vision: The ophthalmological effect of smog in Pakistan Correlation between fall experience and life functions among community-dwelling older adults in Japan Breaking barriers: A gender-based quota system in nursing school admission in Bangladesh Success rates and adherence to antiretroviral therapy among treatment-naïve patients in Davao City, Philippines: A ten-year retrospective cohort study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1