Oxygenation and ventilation during prolonged experimental cardiopulmonary resuscitation with either continuous or 30:2 compression-to-ventilation ratios together with 10 cmH20 positive end-expiratory pressure

IF 2.8 Q2 CRITICAL CARE MEDICINE Intensive Care Medicine Experimental Pub Date : 2024-04-12 DOI:10.1186/s40635-024-00620-z
Jukka Kopra, Erik Litonius, Pirkka T. Pekkarinen, Merja Laitinen, Juho A. Heinonen, Luca Fontanelli, Markus B. Skrifvars
{"title":"Oxygenation and ventilation during prolonged experimental cardiopulmonary resuscitation with either continuous or 30:2 compression-to-ventilation ratios together with 10 cmH20 positive end-expiratory pressure","authors":"Jukka Kopra, Erik Litonius, Pirkka T. Pekkarinen, Merja Laitinen, Juho A. Heinonen, Luca Fontanelli, Markus B. Skrifvars","doi":"10.1186/s40635-024-00620-z","DOIUrl":null,"url":null,"abstract":"In refractory out-of-hospital cardiac arrest, the patient is commonly transported to hospital with mechanical continuous chest compressions (CCC). Limited data are available on the optimal ventilation strategy. Accordingly, we compared arterial oxygenation and haemodynamics during manual asynchronous continuous ventilation and compressions with a 30:2 compression-to-ventilation ratio together with the use of 10 cmH2O positive end-expiratory pressure (PEEP). Intubated and anaesthetized landrace pigs with electrically induced ventricular fibrillation were left untreated for 5 min (n = 31, weight ca. 55 kg), after which they were randomized to either the CCC group or the 30:2 group with the the LUCAS® 2 piston device and bag-valve ventilation with 100% oxygen targeting a tidal volume of 8 ml/kg with a PEEP of 10 cmH2O for 35 min. Arterial blood samples were analysed every 5 min, vital signs, near-infrared spectroscopy and electrical impedance tomography (EIT) were measured continuously, and post-mortem CT scans of the lungs were obtained. The arterial blood values (median + interquartile range) at the 30-min time point were as follows: PaO2: 180 (86–302) mmHg for the 30:2 group; 70 (49–358) mmHg for the CCC group; PaCO2: 41 (29–53) mmHg for the 30:2 group; 44 (21–67) mmHg for the CCC group; and lactate: 12.8 (10.4–15.5) mmol/l for the 30:2 group; 14.7 (11.8–16.1) mmol/l for the CCC group. The differences were not statistically significant. In linear mixed models, there were no significant differences between the groups. The mean arterial pressures from the femoral artery, end-tidal CO2, distributions of ventilation from EIT and mean aeration of lung tissue in post-mortem CTs were similar between the groups. Eight pneumothoraces occurred in the CCC group and 2 in the 30:2 group, a statistically significant difference (p = 0.04). The 30:2 and CCC protocols with a PEEP of 10 cmH2O resulted in similar gas exchange and vital sign outcomes in an experimental model of prolonged cardiac arrest with mechanical compressions, but the CCC protocol resulted in more post-mortem pneumothoraces.","PeriodicalId":13750,"journal":{"name":"Intensive Care Medicine Experimental","volume":"41 1","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intensive Care Medicine Experimental","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s40635-024-00620-z","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CRITICAL CARE MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

In refractory out-of-hospital cardiac arrest, the patient is commonly transported to hospital with mechanical continuous chest compressions (CCC). Limited data are available on the optimal ventilation strategy. Accordingly, we compared arterial oxygenation and haemodynamics during manual asynchronous continuous ventilation and compressions with a 30:2 compression-to-ventilation ratio together with the use of 10 cmH2O positive end-expiratory pressure (PEEP). Intubated and anaesthetized landrace pigs with electrically induced ventricular fibrillation were left untreated for 5 min (n = 31, weight ca. 55 kg), after which they were randomized to either the CCC group or the 30:2 group with the the LUCAS® 2 piston device and bag-valve ventilation with 100% oxygen targeting a tidal volume of 8 ml/kg with a PEEP of 10 cmH2O for 35 min. Arterial blood samples were analysed every 5 min, vital signs, near-infrared spectroscopy and electrical impedance tomography (EIT) were measured continuously, and post-mortem CT scans of the lungs were obtained. The arterial blood values (median + interquartile range) at the 30-min time point were as follows: PaO2: 180 (86–302) mmHg for the 30:2 group; 70 (49–358) mmHg for the CCC group; PaCO2: 41 (29–53) mmHg for the 30:2 group; 44 (21–67) mmHg for the CCC group; and lactate: 12.8 (10.4–15.5) mmol/l for the 30:2 group; 14.7 (11.8–16.1) mmol/l for the CCC group. The differences were not statistically significant. In linear mixed models, there were no significant differences between the groups. The mean arterial pressures from the femoral artery, end-tidal CO2, distributions of ventilation from EIT and mean aeration of lung tissue in post-mortem CTs were similar between the groups. Eight pneumothoraces occurred in the CCC group and 2 in the 30:2 group, a statistically significant difference (p = 0.04). The 30:2 and CCC protocols with a PEEP of 10 cmH2O resulted in similar gas exchange and vital sign outcomes in an experimental model of prolonged cardiac arrest with mechanical compressions, but the CCC protocol resulted in more post-mortem pneumothoraces.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
持续或 30:2 压缩通气比加上 10 cmH20 呼气末正压的长时间实验性心肺复苏过程中的氧合和通气情况
在院外发生难治性心脏骤停时,通常会对患者进行机械持续胸外按压 (CCC),然后将其送往医院。有关最佳通气策略的数据十分有限。因此,我们比较了人工异步持续通气和按压时的动脉氧合和血流动力学,按压与通气比为 30:2,同时使用 10 cmH2O 呼气末正压(PEEP)。插管并麻醉的电击诱发心室颤动的陆地猪在未经处理的情况下静置 5 分钟(n = 31,体重约 55 千克),然后将其随机分配到 CCC 组或 30:2 组,使用 LUCAS® 2 活塞装置和以潮气量 8 毫升/千克为目标的 100% 氧气、10 cmH2O PEEP 的袋阀通气,持续 35 分钟。每 5 分钟分析一次动脉血样本,连续测量生命体征、近红外光谱和电阻抗断层扫描(EIT),并在死后进行肺部 CT 扫描。30 分钟时间点的动脉血值(中位数+四分位间范围)如下:PaO2:30:2组为180(86-302)mmHg;CCC组为70(49-358)mmHg;PaCO2:30:2组为41(29-53)毫米汞柱;CCC组为44(21-67)毫米汞柱;乳酸:30:2 组为 12.8 (10.4-15.5) mmol/l;CCC 组为 14.7 (11.8-16.1) mmol/l。差异无统计学意义。在线性混合模型中,组间差异不明显。两组间的股动脉平均动脉压、潮气末二氧化碳、EIT通气分布和死后CT肺组织平均通气量相似。CCC 组发生了 8 次气胸,30:2 组发生了 2 次,差异有统计学意义(P = 0.04)。在使用机械按压的长时间心脏骤停实验模型中,采用 PEEP 为 10 cmH2O 的 30:2 方案和 CCC 方案产生的气体交换和生命体征结果相似,但 CCC 方案导致更多的死后气胸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Intensive Care Medicine Experimental
Intensive Care Medicine Experimental CRITICAL CARE MEDICINE-
CiteScore
5.10
自引率
2.90%
发文量
48
审稿时长
13 weeks
期刊最新文献
Target-controlled dialysis for antibiotics (TCD-ABx). Assessment of mitochondrial function and its prognostic role in sepsis: a literature review. Predictors of intradialytic hypotension in critically ill patients undergoing kidney replacement therapy: a systematic review. Is passive leg raising clinically useful in predicting intradialytic hypotension? Largely ignored-but pathogenetically significant: ambient temperature in rodent sepsis models.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1