Abdalrahman Mohieddin Kusaibati, Kinda Sultan, Mohammad Younis Hajeer, Nikolaos Gkantidis
{"title":"Digital setup accuracy for moderate crowding correction with fixed orthodontic appliances: a prospective study","authors":"Abdalrahman Mohieddin Kusaibati, Kinda Sultan, Mohammad Younis Hajeer, Nikolaos Gkantidis","doi":"10.1186/s40510-024-00513-7","DOIUrl":null,"url":null,"abstract":"To evaluate the accuracy of a semi-automatic 3D digital setup process in predicting the orthodontic treatment outcome achieved by labial fixed appliances. Twenty-five adult patients (18 to 24 years old) with class I malocclusion and moderate crowding were prospectively enrolled and received treatment on both jaws through the straight-wire technique. Prior to treatment commencement, a semi-automatic digital setup simulating the predicted treatment outcome was performed for each patient through Orthoanalyzer software (3Shape®, Copenhagen, Denmark) to obtain the prediction model. This was compared to the final outcome model through 3D superimposition methods. Metric variables and inspection of color-coded distance maps were used to detect how accurately the digital setup predicts the actual treatment outcome. The mean absolute distances (MAD) between the superimposed dental arches of the predicted and the final models were: 0.77 ± 0.13 mm following superimposition on the palate, 0.52 ± 0.06 mm following superimposition on the maxillary dental arch, and 0.55 ± 0.15 mm following superimposition on the mandibular dental arch. The MAD at the palatal reference area was 0.09 ± 0.04 mm. Visualization of color-coded distance maps indicated that the digital setup accurately predicted the final teeth position in a few cases. Almost half of the cases had posteriorly wider upper and lower dental arches and palatally/lingually positioned or inclined anterior teeth, whereas the rest still showed errors within 2–3 mm, distributed over the entire dental arches with no distinct pattern. The accuracy of semi-automatic prediction of the labial fixed appliance treatment outcome in Class I cases with moderate crowding is not yet sufficient. While average measures showed deviations less than 1 mm, examination of individual color-coded distance maps revealed significant disparities between the simulated and the actual results.","PeriodicalId":56071,"journal":{"name":"Progress in Orthodontics","volume":null,"pages":null},"PeriodicalIF":4.8000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40510-024-00513-7","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
To evaluate the accuracy of a semi-automatic 3D digital setup process in predicting the orthodontic treatment outcome achieved by labial fixed appliances. Twenty-five adult patients (18 to 24 years old) with class I malocclusion and moderate crowding were prospectively enrolled and received treatment on both jaws through the straight-wire technique. Prior to treatment commencement, a semi-automatic digital setup simulating the predicted treatment outcome was performed for each patient through Orthoanalyzer software (3Shape®, Copenhagen, Denmark) to obtain the prediction model. This was compared to the final outcome model through 3D superimposition methods. Metric variables and inspection of color-coded distance maps were used to detect how accurately the digital setup predicts the actual treatment outcome. The mean absolute distances (MAD) between the superimposed dental arches of the predicted and the final models were: 0.77 ± 0.13 mm following superimposition on the palate, 0.52 ± 0.06 mm following superimposition on the maxillary dental arch, and 0.55 ± 0.15 mm following superimposition on the mandibular dental arch. The MAD at the palatal reference area was 0.09 ± 0.04 mm. Visualization of color-coded distance maps indicated that the digital setup accurately predicted the final teeth position in a few cases. Almost half of the cases had posteriorly wider upper and lower dental arches and palatally/lingually positioned or inclined anterior teeth, whereas the rest still showed errors within 2–3 mm, distributed over the entire dental arches with no distinct pattern. The accuracy of semi-automatic prediction of the labial fixed appliance treatment outcome in Class I cases with moderate crowding is not yet sufficient. While average measures showed deviations less than 1 mm, examination of individual color-coded distance maps revealed significant disparities between the simulated and the actual results.
期刊介绍:
Progress in Orthodontics is a fully open access, international journal owned by the Italian Society of Orthodontics and published under the brand SpringerOpen. The Society is currently covering all publication costs so there are no article processing charges for authors.
It is a premier journal of international scope that fosters orthodontic research, including both basic research and development of innovative clinical techniques, with an emphasis on the following areas:
• Mechanisms to improve orthodontics
• Clinical studies and control animal studies
• Orthodontics and genetics, genomics
• Temporomandibular joint (TMJ) control clinical trials
• Efficacy of orthodontic appliances and animal models
• Systematic reviews and meta analyses
• Mechanisms to speed orthodontic treatment
Progress in Orthodontics will consider for publication only meritorious and original contributions. These may be:
• Original articles reporting the findings of clinical trials, clinically relevant basic scientific investigations, or novel therapeutic or diagnostic systems
• Review articles on current topics
• Articles on novel techniques and clinical tools
• Articles of contemporary interest