Low-frequency pulse-jitter measurement with the uGMRT I : PSR J0437–4715

IF 5.4 3区 材料科学 Q2 CHEMISTRY, PHYSICAL ACS Applied Energy Materials Pub Date : 2024-04-16 DOI:10.1017/pasa.2024.30
Tomonosuke Kikunaga, Shinnosuke Hisano, Neelam Dhanda Batra, Shantanu Desai, Bhal Chandra Joshi, Manjari Bagchi, T. Prabu, Keitaro Takahashi, Swetha Arumugam, Adarsh Bathula, Subhajit Dandapat, Debabrata Deb, Churchil Dwivedi, Yashwant Gupta, Shebin Jose Jacob, Fazal Kareem, K Nobleson, Pragna Mamidipaka, Avinash Kumar Paladi, Arul Pandian B, Prerna Rana, Jaikhomba Singha, Aman Srivastava, Mayuresh Surnis, Pratik Tarafdar
{"title":"Low-frequency pulse-jitter measurement with the uGMRT I : PSR J0437–4715","authors":"Tomonosuke Kikunaga, Shinnosuke Hisano, Neelam Dhanda Batra, Shantanu Desai, Bhal Chandra Joshi, Manjari Bagchi, T. Prabu, Keitaro Takahashi, Swetha Arumugam, Adarsh Bathula, Subhajit Dandapat, Debabrata Deb, Churchil Dwivedi, Yashwant Gupta, Shebin Jose Jacob, Fazal Kareem, K Nobleson, Pragna Mamidipaka, Avinash Kumar Paladi, Arul Pandian B, Prerna Rana, Jaikhomba Singha, Aman Srivastava, Mayuresh Surnis, Pratik Tarafdar","doi":"10.1017/pasa.2024.30","DOIUrl":null,"url":null,"abstract":"High-precision pulsar timing observations are limited in their accuracy by the jitter noise that appears in the arrival time of pulses. Therefore, it is important to systematically characterise the amplitude of the jitter noise and its variation with frequency. In this paper, we provide jitter measurements from low-frequency wideband observations of PSR J0437–4715 using data obtained as part of the Indian Pulsar Timing Array experiment. We were able to detect jitter in both the 300 - 500 MHz and 1260 - 1460 MHz observations of the upgraded Giant Metrewave Radio Telescope (uGMRT). The former is the first jitter measurement for this pulsar below 700 MHz, and the latter is in good agreement with results from previous studies. In addition, at 300 - 500 MHz, we investigated the frequency dependence of the jitter by calculating the jitter for each sub-banded arrival time of pulses. We found that the jitter amplitude increases with frequency. This trend is opposite as compared to previous studies, indicating that there is a turnover at intermediate frequencies. It will be possible to investigate this in more detail with uGMRT observations at 550 - 750 MHz and future high sensitive wideband observations from next generation telescopes, such as the Square Kilometre Array. We also explored the effect of jitter on the high precision dispersion measure (DM) measurements derived from short duration observations. We find that even though the DM precision will be better at lower frequencies due to the smaller amplitude of jitter noise, it will limit the DM precision for high signal-to-noise observations, which are of short durations. This limitation can be overcome by integrating for a long enough duration optimised for a given pulsar.","PeriodicalId":4,"journal":{"name":"ACS Applied Energy Materials","volume":null,"pages":null},"PeriodicalIF":5.4000,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Energy Materials","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1017/pasa.2024.30","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

High-precision pulsar timing observations are limited in their accuracy by the jitter noise that appears in the arrival time of pulses. Therefore, it is important to systematically characterise the amplitude of the jitter noise and its variation with frequency. In this paper, we provide jitter measurements from low-frequency wideband observations of PSR J0437–4715 using data obtained as part of the Indian Pulsar Timing Array experiment. We were able to detect jitter in both the 300 - 500 MHz and 1260 - 1460 MHz observations of the upgraded Giant Metrewave Radio Telescope (uGMRT). The former is the first jitter measurement for this pulsar below 700 MHz, and the latter is in good agreement with results from previous studies. In addition, at 300 - 500 MHz, we investigated the frequency dependence of the jitter by calculating the jitter for each sub-banded arrival time of pulses. We found that the jitter amplitude increases with frequency. This trend is opposite as compared to previous studies, indicating that there is a turnover at intermediate frequencies. It will be possible to investigate this in more detail with uGMRT observations at 550 - 750 MHz and future high sensitive wideband observations from next generation telescopes, such as the Square Kilometre Array. We also explored the effect of jitter on the high precision dispersion measure (DM) measurements derived from short duration observations. We find that even though the DM precision will be better at lower frequencies due to the smaller amplitude of jitter noise, it will limit the DM precision for high signal-to-noise observations, which are of short durations. This limitation can be overcome by integrating for a long enough duration optimised for a given pulsar.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 uGMRT I 测量低频脉冲抖动:PSR J0437-4715
高精度脉冲星定时观测的精度受到脉冲到达时间中出现的抖动噪声的限制。因此,系统地描述抖动噪声的振幅及其随频率的变化非常重要。在本文中,我们利用印度脉冲星定时阵列实验获得的数据,对 PSR J0437-4715 进行了低频宽带观测,并提供了抖动测量结果。我们能够在升级版巨型移波射电望远镜(uGMRT)的 300 - 500 MHz 和 1260 - 1460 MHz 观测中探测到抖动。前者是首次在 700 MHz 以下对该脉冲星进行的抖动测量,后者与之前的研究结果非常吻合。此外,在 300 - 500 MHz 波段,我们通过计算每个子波段脉冲到达时间的抖动,研究了抖动的频率依赖性。我们发现,抖动幅度随频率的增加而增加。与之前的研究相比,这一趋势正好相反,表明在中间频率上存在一个转换。通过 uGMRT 在 550-750 MHz 的观测以及未来下一代望远镜(如平方千米阵列)的高灵敏度宽带观测,将有可能对此进行更详细的研究。我们还探讨了抖动对短时间观测得出的高精度色散测量(DM)结果的影响。我们发现,尽管由于抖动噪声的振幅较小,较低频率下的频散测量精度会更好,但它会限制高信噪比观测的频散测量精度,而高信噪比观测的持续时间较短。这种限制可以通过为特定脉冲星优化足够长的持续时间来克服。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Energy Materials
ACS Applied Energy Materials Materials Science-Materials Chemistry
CiteScore
10.30
自引率
6.20%
发文量
1368
期刊介绍: ACS Applied Energy Materials is an interdisciplinary journal publishing original research covering all aspects of materials, engineering, chemistry, physics and biology relevant to energy conversion and storage. The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrate knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important energy applications.
期刊最新文献
Red ginseng polysaccharide promotes ferroptosis in gastric cancer cells by inhibiting PI3K/Akt pathway through down-regulation of AQP3. Diagnostic value of 18F-PSMA-1007 PET/CT for predicting the pathological grade of prostate cancer. Correction. Wilms' tumor 1 -targeting cancer vaccine: Recent advancements and future perspectives. Toll-like receptor agonists as cancer vaccine adjuvants.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1