Optimized Viewing Techniques to Minimize Radiation Damage From X-ray Imaging Systems

IF 2.6 3区 材料科学 Q2 MATERIALS SCIENCE, CHARACTERIZATION & TESTING Journal of Nondestructive Evaluation Pub Date : 2024-04-20 DOI:10.1007/s10921-024-01060-1
Michael P. Pfeifer, Nathanael Simerl, John Porter, Walter J. McNeil, Amir A. Bahadori
{"title":"Optimized Viewing Techniques to Minimize Radiation Damage From X-ray Imaging Systems","authors":"Michael P. Pfeifer, Nathanael Simerl, John Porter, Walter J. McNeil, Amir A. Bahadori","doi":"10.1007/s10921-024-01060-1","DOIUrl":null,"url":null,"abstract":"<p>X-ray inspection of ball grid arrays (BGAs) is typically performed at one or more viewing angles to examine adhesion sites for errors such as voids, joint cracking, or head-in-pillow. During this inspection process, the circuit board assembly is subject to ionizing radiation exposure, which can cause trapped charge within oxide layers of semiconductor devices. Some x-ray machines allow for programmable inspection routines, which could be used to optimize radiation exposure to semiconductor components. Using Monte Carlo methods, x-ray inspection of a BGA was simulated to determine a range of acceptable viewing angles. Dose rates to circuit board components were estimated at each inspection angle to determine the view resulting in optimized radiation exposure. Results showed that for each BGA, the maximum unobstructed viewing times without exceeding a 5 Gy dose limit to a single part ranged from 82 to 94 min. Using a radiation cost function method, optimized viewing across all components was found. It was observed that for a consistent dose limit applied to silicon-based components, performing inspection with BGAs facing the x-ray source was optimal. A third method was applied, assigning individual dose limits based on empirical data from the NASA Goddard Space Flight Center radiation database. This method showed that optimized viewing maximizes the distance between the radiation source and highly sensitive components. It was also observed that cumulative effects from viewing two BGAs will influence viewing angles, causing the optimal view of one BGA to exist nearly 180<span>\\(^\\circ \\)</span> from the other.</p>","PeriodicalId":655,"journal":{"name":"Journal of Nondestructive Evaluation","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nondestructive Evaluation","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1007/s10921-024-01060-1","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

Abstract

X-ray inspection of ball grid arrays (BGAs) is typically performed at one or more viewing angles to examine adhesion sites for errors such as voids, joint cracking, or head-in-pillow. During this inspection process, the circuit board assembly is subject to ionizing radiation exposure, which can cause trapped charge within oxide layers of semiconductor devices. Some x-ray machines allow for programmable inspection routines, which could be used to optimize radiation exposure to semiconductor components. Using Monte Carlo methods, x-ray inspection of a BGA was simulated to determine a range of acceptable viewing angles. Dose rates to circuit board components were estimated at each inspection angle to determine the view resulting in optimized radiation exposure. Results showed that for each BGA, the maximum unobstructed viewing times without exceeding a 5 Gy dose limit to a single part ranged from 82 to 94 min. Using a radiation cost function method, optimized viewing across all components was found. It was observed that for a consistent dose limit applied to silicon-based components, performing inspection with BGAs facing the x-ray source was optimal. A third method was applied, assigning individual dose limits based on empirical data from the NASA Goddard Space Flight Center radiation database. This method showed that optimized viewing maximizes the distance between the radiation source and highly sensitive components. It was also observed that cumulative effects from viewing two BGAs will influence viewing angles, causing the optimal view of one BGA to exist nearly 180\(^\circ \) from the other.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
优化观察技术,将 X 射线成像系统的辐射损伤降至最低
球栅阵列 (BGA) 的 X 射线检测通常在一个或多个观察角度下进行,以检查粘合位置是否存在错误,如空洞、接合处开裂或枕木头。在检查过程中,电路板组件会受到电离辐射照射,这可能会在半导体器件的氧化层中产生滞留电荷。某些 X 射线设备允许可编程检测程序,可用于优化半导体元件的辐射照射。使用蒙特卡洛方法模拟了对 BGA 的 X 射线检测,以确定可接受的观察角度范围。对每个检测角度下电路板元件的剂量率进行了估算,以确定可优化辐射照射的视角。结果显示,对于每个 BGA,在不超过单个部件 5 Gy 剂量限制的情况下,最大无障碍观察时间从 82 分钟到 94 分钟不等。利用辐射成本函数法,找到了所有部件的最佳观察方法。据观察,对于硅基元件的一致剂量限制,BGA 面向 X 射线源进行检测是最佳的。第三种方法是根据美国国家航空航天局戈达德太空飞行中心辐射数据库的经验数据来分配单个剂量限值。该方法表明,优化观察可最大限度地拉近辐射源与高敏感元件之间的距离。还观察到,观察两个 BGA 的累积效应会影响观察角度,导致一个 BGA 的最佳观察角度与另一个 BGA 的最佳观察角度相差近 180(^\circ \)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Nondestructive Evaluation
Journal of Nondestructive Evaluation 工程技术-材料科学:表征与测试
CiteScore
4.90
自引率
7.10%
发文量
67
审稿时长
9 months
期刊介绍: Journal of Nondestructive Evaluation provides a forum for the broad range of scientific and engineering activities involved in developing a quantitative nondestructive evaluation (NDE) capability. This interdisciplinary journal publishes papers on the development of new equipment, analyses, and approaches to nondestructive measurements.
期刊最新文献
The Detection of Local Impact Fatigue Damage on Metal Materials by Combining Nonlinear Acoustic Modulation and Coda Wave Interferometry Feasibility Study on the Use of the Coplanar Capacitive Sensing Technique for Underwater Non-Destructive Evaluation A Method for Semi-automatic Mode Recognition in Acoustic Emission Signals Incipient Near Surface Cracks Characterization and Crack Size Estimation based on Jensen–Shannon Divergence and Wasserstein Distance Adaptive and High-Precision Isosurface Meshes from CT Data
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1