Effect size varies based on calculation method and may affect interpretation of treatment effect: an illustration using randomised clinical trials in osteoarthritis
Thomas J. Schnitzer, Philip G. Conaghan, Francis Berenbaum, Lucy Abraham, Joseph C. Cappelleri, Andrew G. Bushmakin, Lars Viktrup, Ruoyong Yang, Mark T. Brown
{"title":"Effect size varies based on calculation method and may affect interpretation of treatment effect: an illustration using randomised clinical trials in osteoarthritis","authors":"Thomas J. Schnitzer, Philip G. Conaghan, Francis Berenbaum, Lucy Abraham, Joseph C. Cappelleri, Andrew G. Bushmakin, Lars Viktrup, Ruoyong Yang, Mark T. Brown","doi":"10.1186/s42358-024-00358-y","DOIUrl":null,"url":null,"abstract":"To illustrate how (standardised) effect sizes (ES) vary based on calculation method and to provide considerations for improved reporting. Data from three trials of tanezumab in subjects with osteoarthritis were analyzed. ES of tanezumab versus comparator for WOMAC Pain (outcome) was defined as least squares difference between means (mixed model for repeated measures analysis) divided by a pooled standard deviation (SD) of outcome scores. Three approaches to computing the SD were evaluated: Baseline (the pooled SD of WOMAC Pain values at baseline [pooled across treatments]); Endpoint (the pooled SD of these values at the time primary endpoints were assessed); and Median (the median pooled SD of these values based on the pooled SDs across available timepoints). Bootstrap analyses were used to compute 95% confidence intervals (CI). ES (95% CI) of tanezumab 2.5 mg based on Baseline, Endpoint, and Median SDs in one study were − 0.416 (− 0.796, − 0.060), − 0.195 (− 0.371, − 0.028), and − 0.196 (− 0.373, − 0.028), respectively; negative values indicate pain improvement. This pattern of ES differences (largest with Baseline SD, smallest with Endpoint SD, Median SD similar to Endpoint SD) was consistent across all studies and doses of tanezumab. Differences in ES affect interpretation of treatment effect. Therefore, we advocate clearly reporting individual elements of ES in addition to its overall calculation. This is particularly important when ES estimates are used to determine sample sizes for clinical trials, as larger ES will lead to smaller sample sizes and potentially underpowered studies. Clinicaltrials.gov NCT02697773, NCT02709486, and NCT02528188.","PeriodicalId":48634,"journal":{"name":"Advances in Rheumatology","volume":"6 1","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Rheumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42358-024-00358-y","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"RHEUMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
To illustrate how (standardised) effect sizes (ES) vary based on calculation method and to provide considerations for improved reporting. Data from three trials of tanezumab in subjects with osteoarthritis were analyzed. ES of tanezumab versus comparator for WOMAC Pain (outcome) was defined as least squares difference between means (mixed model for repeated measures analysis) divided by a pooled standard deviation (SD) of outcome scores. Three approaches to computing the SD were evaluated: Baseline (the pooled SD of WOMAC Pain values at baseline [pooled across treatments]); Endpoint (the pooled SD of these values at the time primary endpoints were assessed); and Median (the median pooled SD of these values based on the pooled SDs across available timepoints). Bootstrap analyses were used to compute 95% confidence intervals (CI). ES (95% CI) of tanezumab 2.5 mg based on Baseline, Endpoint, and Median SDs in one study were − 0.416 (− 0.796, − 0.060), − 0.195 (− 0.371, − 0.028), and − 0.196 (− 0.373, − 0.028), respectively; negative values indicate pain improvement. This pattern of ES differences (largest with Baseline SD, smallest with Endpoint SD, Median SD similar to Endpoint SD) was consistent across all studies and doses of tanezumab. Differences in ES affect interpretation of treatment effect. Therefore, we advocate clearly reporting individual elements of ES in addition to its overall calculation. This is particularly important when ES estimates are used to determine sample sizes for clinical trials, as larger ES will lead to smaller sample sizes and potentially underpowered studies. Clinicaltrials.gov NCT02697773, NCT02709486, and NCT02528188.
期刊介绍:
Formerly named Revista Brasileira de Reumatologia, the journal is celebrating its 60th year of publication.
Advances in Rheumatology is an international, open access journal publishing pre-clinical, translational and clinical studies on all aspects of paediatric and adult rheumatic diseases, including degenerative, inflammatory and autoimmune conditions. The journal is the official publication of the Brazilian Society of Rheumatology and welcomes original research (including systematic reviews and meta-analyses), literature reviews, guidelines and letters arising from published material.