R. Gillet, Michael Eliezer, Gabriela Hossu, C. Lombard, Fatma Boubaker, Alain Blum, P. G. Gondim Teixeira, Cécile Parietti-Winkler
{"title":"Measurement of stapes footplate thickness using ultra-high-resolution computed tomography: stapes axial plane correlates better with otosclerosis than lateral semicircular canal plane.","authors":"R. Gillet, Michael Eliezer, Gabriela Hossu, C. Lombard, Fatma Boubaker, Alain Blum, P. G. Gondim Teixeira, Cécile Parietti-Winkler","doi":"10.1080/00016489.2024.2340083","DOIUrl":null,"url":null,"abstract":"BACKGROUND, AIMS\nStapes footplate thickness measurement using ultra-high-resolution CT has been described only in the lateral semicircular canal plane. The purpose of this study was to compare stapes footplate thickness between the lateral semicircular canal and stapes axial planes in patients with otosclerosis compared to controls.\n\n\nMATERIAL AND METHODS\nWe performed a retrospective single-center study of patients undergoing high-resolution temporal bone CT. Two radiologists measured stapes footplate thickness in both the lateral semicircular canal and stapes axial planes.\n\n\nRESULTS\nBetween February 2020 and October 2022, we collected 81 ears from 49 patients (75% of women; mean age 51.22 ± 16.6 years, 17 otosclerosis, and 64 controls). In the stapes axial plane, there was a significant anterior thickening in otosclerosis patients (Reader 1: 0.52 ± 0.12 [0.3-0.7] vs. 0.41 ± 0.08 [0.3-0.6], p = 0.001; Reader 2: 0.54 ± 0.06 [0.5-0.7] vs. 0.39 ± 0.08 [0.2-0.6], P < 0.001) compared to controls. These differences were not significant using the lateral semicircular canal plane.\n\n\nCONCLUSION\nThe stapes footplate was thickened at its AC in otosclerosis patients using only the stapes axial plane.\n\n\nSIGNIFICANCE\nWe propose to use the stapes axial plane instead of the lateral semicircular canal plane when analyzing the stapes.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00016489.2024.2340083","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND, AIMS
Stapes footplate thickness measurement using ultra-high-resolution CT has been described only in the lateral semicircular canal plane. The purpose of this study was to compare stapes footplate thickness between the lateral semicircular canal and stapes axial planes in patients with otosclerosis compared to controls.
MATERIAL AND METHODS
We performed a retrospective single-center study of patients undergoing high-resolution temporal bone CT. Two radiologists measured stapes footplate thickness in both the lateral semicircular canal and stapes axial planes.
RESULTS
Between February 2020 and October 2022, we collected 81 ears from 49 patients (75% of women; mean age 51.22 ± 16.6 years, 17 otosclerosis, and 64 controls). In the stapes axial plane, there was a significant anterior thickening in otosclerosis patients (Reader 1: 0.52 ± 0.12 [0.3-0.7] vs. 0.41 ± 0.08 [0.3-0.6], p = 0.001; Reader 2: 0.54 ± 0.06 [0.5-0.7] vs. 0.39 ± 0.08 [0.2-0.6], P < 0.001) compared to controls. These differences were not significant using the lateral semicircular canal plane.
CONCLUSION
The stapes footplate was thickened at its AC in otosclerosis patients using only the stapes axial plane.
SIGNIFICANCE
We propose to use the stapes axial plane instead of the lateral semicircular canal plane when analyzing the stapes.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.