Continuous Shear Wave Elastography for Liver Using Frame-to-Frame Equalization of Complex Amplitude.

IF 2.5 4区 医学 Q1 ACOUSTICS Ultrasonic Imaging Pub Date : 2024-04-23 DOI:10.1177/01617346241247127
Naoki Tano, Ren Koda, Shunichiro Tanigawa, Naohisa Kamiyama, Yoshiki Yamakoshi, Marie Tabaru
{"title":"Continuous Shear Wave Elastography for Liver Using Frame-to-Frame Equalization of Complex Amplitude.","authors":"Naoki Tano, Ren Koda, Shunichiro Tanigawa, Naohisa Kamiyama, Yoshiki Yamakoshi, Marie Tabaru","doi":"10.1177/01617346241247127","DOIUrl":null,"url":null,"abstract":"This study addresses a crucial necessity in the field of noninvasive liver fibrosis diagnosis by introducing the concept of continuous shear wave elastography (C-SWE), utilizing an external vibration source and color Doppler imaging. However, an application of C-SWE to assess liver elasticity, a deep region within the human body, arises an issue of signal instability in the obtained data. To tackle this challenge, this work proposes a method involving the acquisition of multiple frames of datasets, which are subsequently compressed. Furthermore, the proposed frame-to-frame equalization method compensates discrepancies in the initial phase that might exist among multiple-frame datasets, thereby significantly enhancing signal stability. The experimental validation of this approach encompasses both phantom tests and in vivo experiments. In the phantom tests, the proposed technique is validated through a comparison with the established shear wave elastography (SWE) technique. The results demonstrate a remarkable agreement, with an error in shear wave velocity of less than 4.2%. Additionally, the efficacy of the proposed method is confirmed through in vivo tests. As a result, the stabilization of observed shear waves using the frame-to-frame equalization technique exhibits promising potential for accurately assessing human liver elasticity. These findings collectively underscore the viability of C-SWE as a potential diagnostic instrument for liver fibrosis.","PeriodicalId":49401,"journal":{"name":"Ultrasonic Imaging","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasonic Imaging","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/01617346241247127","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

This study addresses a crucial necessity in the field of noninvasive liver fibrosis diagnosis by introducing the concept of continuous shear wave elastography (C-SWE), utilizing an external vibration source and color Doppler imaging. However, an application of C-SWE to assess liver elasticity, a deep region within the human body, arises an issue of signal instability in the obtained data. To tackle this challenge, this work proposes a method involving the acquisition of multiple frames of datasets, which are subsequently compressed. Furthermore, the proposed frame-to-frame equalization method compensates discrepancies in the initial phase that might exist among multiple-frame datasets, thereby significantly enhancing signal stability. The experimental validation of this approach encompasses both phantom tests and in vivo experiments. In the phantom tests, the proposed technique is validated through a comparison with the established shear wave elastography (SWE) technique. The results demonstrate a remarkable agreement, with an error in shear wave velocity of less than 4.2%. Additionally, the efficacy of the proposed method is confirmed through in vivo tests. As a result, the stabilization of observed shear waves using the frame-to-frame equalization technique exhibits promising potential for accurately assessing human liver elasticity. These findings collectively underscore the viability of C-SWE as a potential diagnostic instrument for liver fibrosis.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用帧间复振幅均衡对肝脏进行连续剪切波弹性成像。
这项研究通过引入连续剪切波弹性成像(C-SWE)的概念,利用外部振动源和彩色多普勒成像技术,解决了无创肝脏纤维化诊断领域的一个关键性难题。然而,在应用 C-SWE 评估肝脏弹性这一人体深部区域时,会出现所获数据信号不稳定的问题。为解决这一难题,这项工作提出了一种方法,涉及获取多帧数据集,然后对其进行压缩。此外,所提出的帧对帧均衡方法可以补偿初始阶段多帧数据集之间可能存在的差异,从而显著提高信号的稳定性。该方法的实验验证包括模型测试和体内实验。在模型测试中,通过与已建立的剪切波弹性成像(SWE)技术进行比较,验证了所提出的技术。结果表明两者的一致性非常好,剪切波速度误差小于 4.2%。此外,体内试验也证实了所提方法的有效性。因此,利用帧对帧均衡技术稳定观测到的剪切波,在准确评估人体肝脏弹性方面具有广阔的前景。这些发现共同强调了 C-SWE 作为肝纤维化潜在诊断工具的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultrasonic Imaging
Ultrasonic Imaging 医学-工程:生物医学
CiteScore
5.10
自引率
8.70%
发文量
15
审稿时长
>12 weeks
期刊介绍: Ultrasonic Imaging provides rapid publication for original and exceptional papers concerned with the development and application of ultrasonic-imaging technology. Ultrasonic Imaging publishes articles in the following areas: theoretical and experimental aspects of advanced methods and instrumentation for imaging
期刊最新文献
Development of a Polymer Ultrasound Contrast Agent Incorporating Nested Carbon Nanodots. Automated Deep Learning-Based Finger Joint Segmentation in 3-D Ultrasound Images With Limited Dataset. CBAM-RIUnet: Breast Tumor Segmentation With Enhanced Breast Ultrasound and Test-Time Augmentation Deep learning Radiomics Based on Two-Dimensional Ultrasound for Predicting the Efficacy of Neoadjuvant Chemotherapy in Breast Cancer SPGAN Optimized by Piranha Foraging Optimization for Thyroid Nodule Classification in Ultrasound Images
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1