A Comparative Study of Two Common Software’s used for Photovoltaic Systems, RETscreen and PVsyst

Boubacar Maikano Abdoulaye, Harouna Souley Ousmane, Sani dan Nomao Harouna, Boukar Makinta
{"title":"A Comparative Study of Two Common Software’s used for Photovoltaic Systems, RETscreen and PVsyst","authors":"Boubacar Maikano Abdoulaye, Harouna Souley Ousmane, Sani dan Nomao Harouna, Boukar Makinta","doi":"10.9734/cjast/2024/v43i54373","DOIUrl":null,"url":null,"abstract":"The use of solar energy in sunny countries is a promising way of compensating for the energy deficit. The benefits of this type of energy are not just economic, but also environmental, since it emits few greenhouse gases. NIGER, a vast landlocked country in the Sahel, has an average level of sunshine estimated at around 5 to 7 kW/m2/d for an average duration of 8.5 hours per day. However, the rate of access to electricity in Niger remains very low. As part of the government's policy to reduce the energy deficit, it has built a 7MW photovoltaic solar power plant at MALBAZA (TAHOUA). The aim of this study was to evaluate the effectiveness of the PVsyst and RETScreen software packages, which are widely used in the solar energy sector. The results of the various simulations were compared with the average of experimental measurements collected over three monitoring years: 2019, 2020 and 2021. These results mainly concern parameters such as the capacity factor (CF), the performance ratio (PR) and the final yield Yf. Error matrices (MBE and NMBE) were used for validation. The plant supplied an average of 11995.94 MWh of energy to the grid during the monitoring period. We obtained a mean bias error (MBE) of 5.81% (PVsyst) and 0.14% (RETSceen) and a normalized mean bias error (NMBE) of 3.81% (PVsyst) and 0.27% (RETScreen). There is good agreement between the experimental measurements and the theoretical values. The RETScreen software has less mean bias error (MBE) and normalized mean bias error (NMBE) than PVsyst, giving a better estimate of the real values.","PeriodicalId":505676,"journal":{"name":"Current Journal of Applied Science and Technology","volume":"325 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Journal of Applied Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/cjast/2024/v43i54373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The use of solar energy in sunny countries is a promising way of compensating for the energy deficit. The benefits of this type of energy are not just economic, but also environmental, since it emits few greenhouse gases. NIGER, a vast landlocked country in the Sahel, has an average level of sunshine estimated at around 5 to 7 kW/m2/d for an average duration of 8.5 hours per day. However, the rate of access to electricity in Niger remains very low. As part of the government's policy to reduce the energy deficit, it has built a 7MW photovoltaic solar power plant at MALBAZA (TAHOUA). The aim of this study was to evaluate the effectiveness of the PVsyst and RETScreen software packages, which are widely used in the solar energy sector. The results of the various simulations were compared with the average of experimental measurements collected over three monitoring years: 2019, 2020 and 2021. These results mainly concern parameters such as the capacity factor (CF), the performance ratio (PR) and the final yield Yf. Error matrices (MBE and NMBE) were used for validation. The plant supplied an average of 11995.94 MWh of energy to the grid during the monitoring period. We obtained a mean bias error (MBE) of 5.81% (PVsyst) and 0.14% (RETSceen) and a normalized mean bias error (NMBE) of 3.81% (PVsyst) and 0.27% (RETScreen). There is good agreement between the experimental measurements and the theoretical values. The RETScreen software has less mean bias error (MBE) and normalized mean bias error (NMBE) than PVsyst, giving a better estimate of the real values.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种光伏系统常用软件 RETscreen 和 PVsyst 的比较研究
在阳光充足的国家,利用太阳能是弥补能源不足的一个可行办法。这种能源不仅具有经济效益,还具有环境效益,因为它排放的温室气体很少。尼日尔是萨赫勒地区一个幅员辽阔的内陆国家,平均日照量约为 5-7 kW/m2/d,每天平均日照时间为 8.5 小时。然而,尼日尔的用电率仍然很低。作为政府减少能源赤字政策的一部分,政府在 MALBAZA(塔胡阿)建造了一座 7 兆瓦的光伏太阳能发电站。本研究旨在评估 PVsyst 和 RETScreen 软件包的有效性,这两个软件包在太阳能领域应用广泛。各种模拟结果与 2019、2020 和 2021 这三个监测年度收集的实验测量平均值进行了比较。这些结果主要涉及容量系数(CF)、性能比(PR)和最终产量 Yf 等参数。误差矩阵(MBE 和 NMBE)用于验证。在监测期间,发电厂平均向电网供应了 11995.94 兆瓦时的电能。我们得到的平均偏差误差(MBE)为 5.81%(PVsyst)和 0.14%(RETSceen),归一化平均偏差误差(NMBE)为 3.81%(PVsyst)和 0.27%(RETScreen)。实验测量值与理论值之间的一致性很好。RETScreen 软件的平均偏置误差 (MBE) 和归一化平均偏置误差 (NMBE) 均小于 PVsyst,能更好地估计实际值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mechanical Properties and Engineering Applications of Flexural and Tensile Properties in Materials Science A Study on Evolution of Optical Fiber Communication from PDH to SDM Technology Study of the Performance of an Indirect Forced Convection Solar Dryer Incorporating a Thermal Energy Storage Device on a Granite Bed for Drying Tomatoes Improving Learning in Robotics Teleoperation: Contribution of Eye-tracking in Digital Ethnography Study of Regular Variations in Vertical Total Electron Content (VTEC) from 2013 to 2021 at Station BF01 in Ouagadougou
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1