Exploratory analysis of the accuracy of echocardiographic parameters for the assessment of right ventricular function and right ventricular–pulmonary artery coupling
H. Shima, I. Tsujino, J. Nakamura, Toshitaka Nakaya, Ayako Sugimoto, Takahiro Sato, Taku Watanabe, H. Ohira, Masaru Suzuki, S. Tsuneta, Y. Chiba, M. Murayama, Isao Yokota, Satoshi Konno
{"title":"Exploratory analysis of the accuracy of echocardiographic parameters for the assessment of right ventricular function and right ventricular–pulmonary artery coupling","authors":"H. Shima, I. Tsujino, J. Nakamura, Toshitaka Nakaya, Ayako Sugimoto, Takahiro Sato, Taku Watanabe, H. Ohira, Masaru Suzuki, S. Tsuneta, Y. Chiba, M. Murayama, Isao Yokota, Satoshi Konno","doi":"10.1002/pul2.12368","DOIUrl":null,"url":null,"abstract":"Echocardiography is a widely used modality for the assessment of right ventricular (RV) function; however, few studies have comprehensively compared the accuracy of echocardiographic parameters using invasively obtained reference values. Therefore, this exploratory study aimed to compare the accuracy of echocardiographic parameters of RV function and RV–pulmonary artery (PA) coupling. We calculated four indices of RV function (end‐systolic elastance [Ees] for systolic function [contractility], τ for relaxation, and β and end‐diastolic elastance [Eed] for stiffness), and an index of RV–PA coupling (Ees/arterial elastance [Ea]), using pressure catheterization, cardiac magnetic resonance imaging, and a single‐beat method. We then compared the correlations of RV indices with echocardiographic parameters. In 63 participants (54 with pulmonary hypertension (PH) and nine without PH), Ees and τ correlated with several echocardiographic parameters, such as RV diameter and area, but the correlations were moderate (|correlation coefficients (ρ)| < 0.5 for all parameters). The correlations of β and Eed with echocardiographic parameters were weak, with |ρ| < 0.4. In contrast, Ees/Ea closely correlated with RV free wall longitudinal strain (RVFW‐LS)/estimated systolic PA pressure (eSPAP) (ρ = −0.72). Ees/Ea also correlated with tricuspid annular plane systolic excursion/eSPAP, RV diameter, and RV end‐systolic area, with |ρ | >0.65. In addition, RVFW‐LS/eSPAP yielded high sensitivity (0.84) and specificity (0.75) for detecting reduced Ees/Ea. The present study indicated a limited accuracy of echocardiographic parameters in assessing RV systolic and diastolic function. In contrast to RV function, they showed high accuracy for assessing RV–PA coupling, with RVFW‐LS/eSPAP exhibiting the highest accuracy.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"253 ","pages":""},"PeriodicalIF":4.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/pul2.12368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Echocardiography is a widely used modality for the assessment of right ventricular (RV) function; however, few studies have comprehensively compared the accuracy of echocardiographic parameters using invasively obtained reference values. Therefore, this exploratory study aimed to compare the accuracy of echocardiographic parameters of RV function and RV–pulmonary artery (PA) coupling. We calculated four indices of RV function (end‐systolic elastance [Ees] for systolic function [contractility], τ for relaxation, and β and end‐diastolic elastance [Eed] for stiffness), and an index of RV–PA coupling (Ees/arterial elastance [Ea]), using pressure catheterization, cardiac magnetic resonance imaging, and a single‐beat method. We then compared the correlations of RV indices with echocardiographic parameters. In 63 participants (54 with pulmonary hypertension (PH) and nine without PH), Ees and τ correlated with several echocardiographic parameters, such as RV diameter and area, but the correlations were moderate (|correlation coefficients (ρ)| < 0.5 for all parameters). The correlations of β and Eed with echocardiographic parameters were weak, with |ρ| < 0.4. In contrast, Ees/Ea closely correlated with RV free wall longitudinal strain (RVFW‐LS)/estimated systolic PA pressure (eSPAP) (ρ = −0.72). Ees/Ea also correlated with tricuspid annular plane systolic excursion/eSPAP, RV diameter, and RV end‐systolic area, with |ρ | >0.65. In addition, RVFW‐LS/eSPAP yielded high sensitivity (0.84) and specificity (0.75) for detecting reduced Ees/Ea. The present study indicated a limited accuracy of echocardiographic parameters in assessing RV systolic and diastolic function. In contrast to RV function, they showed high accuracy for assessing RV–PA coupling, with RVFW‐LS/eSPAP exhibiting the highest accuracy.
期刊介绍:
ACS Applied Bio Materials is an interdisciplinary journal publishing original research covering all aspects of biomaterials and biointerfaces including and beyond the traditional biosensing, biomedical and therapeutic applications.
The journal is devoted to reports of new and original experimental and theoretical research of an applied nature that integrates knowledge in the areas of materials, engineering, physics, bioscience, and chemistry into important bio applications. The journal is specifically interested in work that addresses the relationship between structure and function and assesses the stability and degradation of materials under relevant environmental and biological conditions.