Rebecca Handermann, Nathalie Zehender, Stefan Rues, Hiro Kobayashi, Peter Rammelsberg, Franz Sebastian Schwindling
{"title":"Load-bearing capacity of 3D-printed incisor partial-coverage crowns made from zirconia and composite","authors":"Rebecca Handermann, Nathalie Zehender, Stefan Rues, Hiro Kobayashi, Peter Rammelsberg, Franz Sebastian Schwindling","doi":"10.2186/jpr.jpr_d_23_00028","DOIUrl":null,"url":null,"abstract":"</p><p><b>Purpose:</b> This study investigated the fracture resistance of 0.5-mm-thick restorations for minimally invasive therapy. Anterior partial-coverage crowns composed of three-dimensional (3D)-printed 3-mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP; Lithacon 3Y210, Lithoz) and 3D-printed composite (Varseo Smile Crown plus, Bego) were compared with a control group made from milled 3Y-TZP (Cercon ht, DentsplySirona).</p><p><b>Methods:</b> Three groups each with 27 restorations were produced. For milled 3Y-TZP partial-coverage crowns, drill compensation was needed so the milling bur could access the inner surface at the incisal edge. Restoration fit was verified by cross-sectioning 12 specimens in each group. The remaining 15 restorations were sandblasted (Al2O3, 0.1 MPa) and adhesively cemented (Panavia SA, Kuraray) onto CoCr teeth. Static load-to-failure tests were performed. The load was induced on the incisal edge. The forces needed to fracture the specimens were analyzed using the Welch analysis of variance and post hoc Dunnet-T3 tests. The Weibull parameters were also calculated.</p><p><b>Results:</b> Drill compensation increased cement thickness at the loading area by 200 µm in milled 3Y-TZP restorations compared with the 3D-printed partial-coverage crowns. Fracture resistance was the highest in 3D-printed 3Y-TZP restorations (1570±661N) followed by milled 3Y-TZP (886±164N) and 3D-printed composite partial-coverage crowns (570±233 N). Milled 3Y-TZP was associated with a substantially higher Weibull modulus (m=6) than the 3D-printed materials (m=2), suggesting greater reliability.</p><p><b>Conclusions:</b> Fracture resistance increased with tighter fit, demonstrating the benefit of the geometric freedom associated with 3D-printing. Future research should focus on making 3D-printed 3Y-TZP more reliable to increase its safety in clinical use.</p>\n<p></p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":"15 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-04-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of prosthodontic research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.jpr_d_23_00028","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study investigated the fracture resistance of 0.5-mm-thick restorations for minimally invasive therapy. Anterior partial-coverage crowns composed of three-dimensional (3D)-printed 3-mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP; Lithacon 3Y210, Lithoz) and 3D-printed composite (Varseo Smile Crown plus, Bego) were compared with a control group made from milled 3Y-TZP (Cercon ht, DentsplySirona).
Methods: Three groups each with 27 restorations were produced. For milled 3Y-TZP partial-coverage crowns, drill compensation was needed so the milling bur could access the inner surface at the incisal edge. Restoration fit was verified by cross-sectioning 12 specimens in each group. The remaining 15 restorations were sandblasted (Al2O3, 0.1 MPa) and adhesively cemented (Panavia SA, Kuraray) onto CoCr teeth. Static load-to-failure tests were performed. The load was induced on the incisal edge. The forces needed to fracture the specimens were analyzed using the Welch analysis of variance and post hoc Dunnet-T3 tests. The Weibull parameters were also calculated.
Results: Drill compensation increased cement thickness at the loading area by 200 µm in milled 3Y-TZP restorations compared with the 3D-printed partial-coverage crowns. Fracture resistance was the highest in 3D-printed 3Y-TZP restorations (1570±661N) followed by milled 3Y-TZP (886±164N) and 3D-printed composite partial-coverage crowns (570±233 N). Milled 3Y-TZP was associated with a substantially higher Weibull modulus (m=6) than the 3D-printed materials (m=2), suggesting greater reliability.
Conclusions: Fracture resistance increased with tighter fit, demonstrating the benefit of the geometric freedom associated with 3D-printing. Future research should focus on making 3D-printed 3Y-TZP more reliable to increase its safety in clinical use.
期刊介绍:
Journal of Prosthodontic Research is published 4 times annually, in January, April, July, and October, under supervision by the Editorial Board of Japan Prosthodontic Society, which selects all materials submitted for publication.
Journal of Prosthodontic Research originated as an official journal of Japan Prosthodontic Society. It has recently developed a long-range plan to become the most prestigious Asian journal of dental research regarding all aspects of oral and occlusal rehabilitation, fixed/removable prosthodontics, oral implantology and applied oral biology and physiology. The Journal will cover all diagnostic and clinical management aspects necessary to reestablish subjective and objective harmonious oral aesthetics and function.
The most-targeted topics:
1) Clinical Epidemiology and Prosthodontics
2) Fixed/Removable Prosthodontics
3) Oral Implantology
4) Prosthodontics-Related Biosciences (Regenerative Medicine, Bone Biology, Mechanobiology, Microbiology/Immunology)
5) Oral Physiology and Biomechanics (Masticating and Swallowing Function, Parafunction, e.g., bruxism)
6) Orofacial Pain and Temporomandibular Disorders (TMDs)
7) Adhesive Dentistry / Dental Materials / Aesthetic Dentistry
8) Maxillofacial Prosthodontics and Dysphagia Rehabilitation
9) Digital Dentistry
Prosthodontic treatment may become necessary as a result of developmental or acquired disturbances in the orofacial region, of orofacial trauma, or of a variety of dental and oral diseases and orofacial pain conditions.
Reviews, Original articles, technical procedure and case reports can be submitted. Letters to the Editor commenting on papers or any aspect of Journal of Prosthodontic Research are welcomed.