{"title":"Plasma levels of Sirtuin 7 are decreased in patients with essential hypertension","authors":"Ying Liu , Ying Guo , Ning Wang , Zhaojie Dong , Xiaoyan Yang , Qian Liu , Guohong Wang , Mingzhao Qin , Jiawei Song , Jing Li , Li Xu , Ying Dong , Jiuchang Zhong","doi":"10.1016/j.clinbiochem.2024.110766","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Sirtuin 7 (SIRT7), as a nicotinamide adenine dinucleotide-dependent protein/histone deacetylase, has been implicated in the pathogenesis of cardiovascular diseases. However, whether SIRT7 is related to hypertension remains largely unclear. Thus, this study aims to explore the effects and correlation between SIRT7 and hypertension.</p></div><div><h3>Methods</h3><p>A total of 72 patients with essential hypertension and 82 controls with non-hypertension were recruited at Beijing Tongren Hospital Affiliated with Capital Medical University from July 2022 to June 2023. Plasma SIRT7 expression was measured using enzyme-linked immunosorbent assay analysis. Clinical baseline characteristics, laboratory measurements, echocardiographic data, and medical therapy were collected.</p></div><div><h3>Results</h3><p>Plasma levels of SIRT7 were lower in hypertensive patients compared with non-hypertensive patients [0.97 (0.58–1.30) vs. 1.24 (0.99–1.46) ng/mL, <em>P</em> < 0.001, respectively]. Furthermore, compared with the low SIRT7 group, there were lower levels of systolic blood pressure, hyperlipidemia, and the ultrasonic electrocardiogram parameters left ventricular end-diastolic diameter and left atrial in diastole in the high SIRT7 group (<em>P</em> < 0.05, respectively). More importantly, multivariate logistic regression analyses indicated that plasma SIRT7 was a predictor of hypertension [OR: 0.06, 95 % CI (0.02–0.19), <em>P</em> < 0.001]. Receiver operating characteristics curve analysis revealed that the optimal cutoff value for plasma SIRT7 levels in detecting hypertension was determined as 0.85 ng/mL with a sensitivity of 73.6 % and a specificity of 89.0 %. The area under the curve for SIRT7 was 0.821 (95 % CI, 0.751–0.878; <em>P</em> < 0.001).</p></div><div><h3>Conclusion</h3><p>Plasma levels of SIRT7 are decreased in patients with essential hypertension, implying its potential as a biomarker for diagnosing essential hypertension..</p></div>","PeriodicalId":10172,"journal":{"name":"Clinical biochemistry","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical biochemistry","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0009912024000602","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Sirtuin 7 (SIRT7), as a nicotinamide adenine dinucleotide-dependent protein/histone deacetylase, has been implicated in the pathogenesis of cardiovascular diseases. However, whether SIRT7 is related to hypertension remains largely unclear. Thus, this study aims to explore the effects and correlation between SIRT7 and hypertension.
Methods
A total of 72 patients with essential hypertension and 82 controls with non-hypertension were recruited at Beijing Tongren Hospital Affiliated with Capital Medical University from July 2022 to June 2023. Plasma SIRT7 expression was measured using enzyme-linked immunosorbent assay analysis. Clinical baseline characteristics, laboratory measurements, echocardiographic data, and medical therapy were collected.
Results
Plasma levels of SIRT7 were lower in hypertensive patients compared with non-hypertensive patients [0.97 (0.58–1.30) vs. 1.24 (0.99–1.46) ng/mL, P < 0.001, respectively]. Furthermore, compared with the low SIRT7 group, there were lower levels of systolic blood pressure, hyperlipidemia, and the ultrasonic electrocardiogram parameters left ventricular end-diastolic diameter and left atrial in diastole in the high SIRT7 group (P < 0.05, respectively). More importantly, multivariate logistic regression analyses indicated that plasma SIRT7 was a predictor of hypertension [OR: 0.06, 95 % CI (0.02–0.19), P < 0.001]. Receiver operating characteristics curve analysis revealed that the optimal cutoff value for plasma SIRT7 levels in detecting hypertension was determined as 0.85 ng/mL with a sensitivity of 73.6 % and a specificity of 89.0 %. The area under the curve for SIRT7 was 0.821 (95 % CI, 0.751–0.878; P < 0.001).
Conclusion
Plasma levels of SIRT7 are decreased in patients with essential hypertension, implying its potential as a biomarker for diagnosing essential hypertension..
期刊介绍:
Clinical Biochemistry publishes articles relating to clinical chemistry, molecular biology and genetics, therapeutic drug monitoring and toxicology, laboratory immunology and laboratory medicine in general, with the focus on analytical and clinical investigation of laboratory tests in humans used for diagnosis, prognosis, treatment and therapy, and monitoring of disease.