Finite Element Analysis of Postoperative Stability of Transverse Scaphoid Waist Fracture

IF 1.1 4区 医学 Q3 ORTHOPEDICS Indian Journal of Orthopaedics Pub Date : 2024-04-28 DOI:10.1007/s43465-024-01156-w
Ayush Srivastav, Prateek Behera, Ravi Kumar Dwivedi, John Ashutosh Santoshi
{"title":"Finite Element Analysis of Postoperative Stability of Transverse Scaphoid Waist Fracture","authors":"Ayush Srivastav, Prateek Behera, Ravi Kumar Dwivedi, John Ashutosh Santoshi","doi":"10.1007/s43465-024-01156-w","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Background and Purpose</h3><p>Scaphoid waist fractures are often stabilised with compression screws, Kirschner wires (K-wires), or a combination of both. While clinical and bio-mechanical studies evaluating their utility are available, the ideal configuration of implant that would provide adequate stability to permit early use of the hand is debatable. We examined configurations of a single screw, one screw along with a K-wire, and two K-wires used for a transverse scaphoid waist fracture fixation aiming to assess the stability provided by each in the immediate postoperative period.</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>Computer-aided design (CAD) models of the scaphoid, K-wire, and headless compression screw were created. A transverse fracture was created at the scaphoid waist, and the CAD models of the screw and K-wire were used to fix the fracture in different configurations in a distal to proximal direction. Finite Element Analysis (FEA) was used to examine the strength of configurations when they were subjected to compression and distraction forces. The total maximum deformation (TDef) and factor of safety (FoS) for each configuration were calculated and used as indirect indicators of postoperative stability.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>When a single screw was used, the configurations with the screw directed posteriorly from either centre or anterior had the best combined TDef and FoS values. For one screw and one K-wire, the configuration with screw and K-wire parallel to each other with the screw located along the long axis in the AP projection and anterior to the K-wire in the lateral projection had the best combined TDef and FoS values. When using two K-wires, configurations with the two wires diverging proximally on the lateral projection had the best combined TDef and FoS values.</p><h3 data-test=\"abstract-sub-heading\">Conclusions</h3><p>When fixing a transverse scaphoid waist fracture with a single screw, the screw directed posteriorly from either the centre or anterior aspect of the distal pole has the best stability, a parallel configuration has the best stability when fixing it using a screw and a K-wire, and divergent configuration has the best stability when fixing it with two K-wires only.</p>","PeriodicalId":13338,"journal":{"name":"Indian Journal of Orthopaedics","volume":"33 1","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2024-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Orthopaedics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s43465-024-01156-w","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Purpose

Scaphoid waist fractures are often stabilised with compression screws, Kirschner wires (K-wires), or a combination of both. While clinical and bio-mechanical studies evaluating their utility are available, the ideal configuration of implant that would provide adequate stability to permit early use of the hand is debatable. We examined configurations of a single screw, one screw along with a K-wire, and two K-wires used for a transverse scaphoid waist fracture fixation aiming to assess the stability provided by each in the immediate postoperative period.

Methods

Computer-aided design (CAD) models of the scaphoid, K-wire, and headless compression screw were created. A transverse fracture was created at the scaphoid waist, and the CAD models of the screw and K-wire were used to fix the fracture in different configurations in a distal to proximal direction. Finite Element Analysis (FEA) was used to examine the strength of configurations when they were subjected to compression and distraction forces. The total maximum deformation (TDef) and factor of safety (FoS) for each configuration were calculated and used as indirect indicators of postoperative stability.

Results

When a single screw was used, the configurations with the screw directed posteriorly from either centre or anterior had the best combined TDef and FoS values. For one screw and one K-wire, the configuration with screw and K-wire parallel to each other with the screw located along the long axis in the AP projection and anterior to the K-wire in the lateral projection had the best combined TDef and FoS values. When using two K-wires, configurations with the two wires diverging proximally on the lateral projection had the best combined TDef and FoS values.

Conclusions

When fixing a transverse scaphoid waist fracture with a single screw, the screw directed posteriorly from either the centre or anterior aspect of the distal pole has the best stability, a parallel configuration has the best stability when fixing it using a screw and a K-wire, and divergent configuration has the best stability when fixing it with two K-wires only.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肩胛骨横向腰部骨折术后稳定性的有限元分析
背景和目的肩胛腰骨折通常采用加压螺钉、Kirschner 线(K 线)或两者结合的方法进行稳定。虽然有临床和生物力学研究对这些方法的效用进行了评估,但究竟哪种理想的植入物结构能提供足够的稳定性,从而使患者能够尽早使用手部,仍存在争议。我们研究了用于横向肩胛腰骨折固定的单根螺钉、一根螺钉和一根 K 型钢丝以及两根 K 型钢丝的配置,旨在评估每种配置在术后初期所提供的稳定性。在肩胛骨腰部创建横向骨折,使用螺钉和 K 型钢丝的 CAD 模型以不同的配置从远端到近端固定骨折。采用有限元分析法(FEA)检验了各构型在受到压缩力和牵拉力时的强度。结果当使用单个螺钉时,螺钉从中心或前方指向后方的配置具有最佳的总最大变形(TDef)和安全系数(FoS)。对于单个螺钉和一根 K 线,螺钉和 K 线相互平行,螺钉在 AP 投影中位于长轴,在侧投影中位于 K 线前方的配置具有最佳的 TDef 和 FoS 综合值。结论当使用单个螺钉固定横肩胛腰骨折时,从远端中心或前方向后方导向的螺钉具有最佳稳定性,当使用螺钉和 K 线固定时,平行配置具有最佳稳定性,当仅使用两根 K 线固定时,发散配置具有最佳稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
185
审稿时长
9 months
期刊介绍: IJO welcomes articles that contribute to Orthopaedic knowledge from India and overseas. We publish articles dealing with clinical orthopaedics and basic research in orthopaedic surgery. Articles are accepted only for exclusive publication in the Indian Journal of Orthopaedics. Previously published articles, articles which are in peer-reviewed electronic publications in other journals, are not accepted by the Journal. Published articles and illustrations become the property of the Journal. The copyright remains with the journal. Studies must be carried out in accordance with World Medical Association Declaration of Helsinki.
期刊最新文献
Technology Update in Management of Multi-Ligament Knee Injuries. From the Guest Editors: Unraveling the Complexities of Multiligament Knee Injuries-A Global Endeavor. Strategies for Preventing Tunnel Convergence in Multiligament Knee Injury Reconstructions. Adjustable Loop Fixation in Multi-ligament Knee Injuries: A Technical Note. Clinical Results of Isolated MCL Grade III Injury in Acute and Chronic Setting: Systematic Review and Meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1