Development and Validation of Fast and Sensitive RP-HPLC Stability-Indicating Method for Quantification of Piroxicam in Bulk Drug

IF 1.5 4区 化学 Q4 BIOCHEMICAL RESEARCH METHODS Journal of chromatographic science Pub Date : 2024-05-05 DOI:10.1093/chromsci/bmae021
Vikas Chauhan, Parul Grover, Monika Bhardwaj, Sandeep Kumar, K Nagarajan
{"title":"Development and Validation of Fast and Sensitive RP-HPLC Stability-Indicating Method for Quantification of Piroxicam in Bulk Drug","authors":"Vikas Chauhan, Parul Grover, Monika Bhardwaj, Sandeep Kumar, K Nagarajan","doi":"10.1093/chromsci/bmae021","DOIUrl":null,"url":null,"abstract":"A simple, rapid, sensitive, and cost-effective green solvent-assisted reverse-phase high-performance liquid chromatographic technique, coupled with a photodiode array detector, was developed and validated for the estimation of piroxicam (PRXM). The chromatographic separation was achieved by using a C-18 (250 × 4.6) mm, 5-μm stationary phase and a mobile phase consisting of methanol and 0.1% ortho-phosphoric acid in water in a ratio of (80:20) v/v at a flow rate of 1 ml/min. The detection was carried out at a wavelength of 254 nm with a constant injection volume of 10 μL throughout the analysis. The calibration curve was observed to be linear over the optimum concentration range of 50–300 μg mL−1, with an R2 value of 0.9995. The developed method was validated as per the International Council for Harmonisation (ICH) Q2 (R1) guideline. Various parameters like selectivity/specificity, accuracy/recovery, linearity, precision, detection limit, quantitation limit, robustness and stability of analyte in solution were performed for the method validation. The PRXM was evaluated under stressed conditions, including acidic, basic, oxidative, thermal and photolytic, as per ICH Q1 (R2) guidelines. Significant degradation was observed in acidic and basic degradation conditions. Conversely, the drug substance showed stability when exposed to oxidative, photolytic and thermal degradation conditions.","PeriodicalId":15430,"journal":{"name":"Journal of chromatographic science","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatographic science","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1093/chromsci/bmae021","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

A simple, rapid, sensitive, and cost-effective green solvent-assisted reverse-phase high-performance liquid chromatographic technique, coupled with a photodiode array detector, was developed and validated for the estimation of piroxicam (PRXM). The chromatographic separation was achieved by using a C-18 (250 × 4.6) mm, 5-μm stationary phase and a mobile phase consisting of methanol and 0.1% ortho-phosphoric acid in water in a ratio of (80:20) v/v at a flow rate of 1 ml/min. The detection was carried out at a wavelength of 254 nm with a constant injection volume of 10 μL throughout the analysis. The calibration curve was observed to be linear over the optimum concentration range of 50–300 μg mL−1, with an R2 value of 0.9995. The developed method was validated as per the International Council for Harmonisation (ICH) Q2 (R1) guideline. Various parameters like selectivity/specificity, accuracy/recovery, linearity, precision, detection limit, quantitation limit, robustness and stability of analyte in solution were performed for the method validation. The PRXM was evaluated under stressed conditions, including acidic, basic, oxidative, thermal and photolytic, as per ICH Q1 (R2) guidelines. Significant degradation was observed in acidic and basic degradation conditions. Conversely, the drug substance showed stability when exposed to oxidative, photolytic and thermal degradation conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
快速灵敏的 RP-HPLC 稳定性指示法的开发与验证,用于定量散装药物中的吡罗昔康
开发并验证了一种简单、快速、灵敏且经济高效的绿色溶剂辅助反相高效液相色谱技术,该技术与光电二极管阵列检测器相结合,用于吡罗昔康(PRXM)的测定。色谱分离采用 C-18 (250 × 4.6) mm、5-μm 固定相,流动相为甲醇和 0.1% 原磷酸水溶液,流速为 1 ml/min,二者的体积比为 (80:20) v/v。检测波长为 254 nm,整个分析过程中的进样量保持为 10 μL。在 50-300 μg mL-1 的最佳浓度范围内,校准曲线呈线性关系,R2 值为 0.9995。所开发的方法按照国际协调理事会(ICH)Q2 (R1)指南进行了验证。对方法的选择性/特异性、准确性/回收率、线性、精密度、检测限、定量限、稳健性和溶液中分析物的稳定性等参数进行了验证。根据 ICH Q1 (R2) 指南,在酸性、碱性、氧化、热和光解等压力条件下对 PRXM 进行了评估。在酸性和碱性降解条件下观察到了明显的降解。相反,药物在氧化、光解和热降解条件下表现出稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.90
自引率
7.70%
发文量
94
审稿时长
5.6 months
期刊介绍: The Journal of Chromatographic Science is devoted to the dissemination of information concerning all methods of chromatographic analysis. The standard manuscript is a description of recent original research that covers any or all phases of a specific separation problem, principle, or method. Manuscripts which have a high degree of novelty and fundamental significance to the field of separation science are particularly encouraged. It is expected the authors will clearly state in the Introduction how their method compares in some markedly new and improved way to previous published related methods. Analytical performance characteristics of new methods including sensitivity, tested limits of detection or quantification, accuracy, precision, and specificity should be provided. Manuscripts which describe a straightforward extension of a known analytical method or an application to a previously analyzed and/or uncomplicated sample matrix will not normally be reviewed favorably. Manuscripts in which mass spectrometry is the dominant analytical method and chromatography is of marked secondary importance may be declined.
期刊最新文献
A GC–MS Method for Determination of β-Propiolactone Residues in Inactivated Covid-19 Vaccines Ayurveda Detoxification Process Reduces Plumbagin from the Roots of Plumbago zeylanica L. - A RP-UFLC Analysis. Green and Sustainable Analytical Chemistry-Driven Chromatographic Method Development for Stability Study of Apixaban Using Box-Behnken Design and Principal Component Analysis. A Sensitive Liquid Chromatography-Mass Spectrometric Method for Determination of Bisoprolol in Rat Serum after Pre-Column Derivatization. Design of Experiment-Based Green UPLC-DAD Method for the Simultaneous Determination of Indacaterol, Glycopyrronium and Mometasone in their Combined Dosage Form and Spiked Human Plasma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1