Validity of the Rezum Simulator for Trainees.

Q2 Medicine Acta Informatica Medica Pub Date : 2023-01-01 DOI:10.5455/aim.2024.32.82-87
Ossamah Saleh Alsowayan, Abdullah Mousa Al Zahrani
{"title":"Validity of the Rezum Simulator for Trainees.","authors":"Ossamah Saleh Alsowayan, Abdullah Mousa Al Zahrani","doi":"10.5455/aim.2024.32.82-87","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Simulations have revolutionized surgical training and are an invaluable adjunct tool for augmenting the proficiency of surgeon and patient safety. Before being included in a practical assessment process, simulators need to be using various validity inference frameworks.</p><p><strong>Objective: </strong>We examine the construct validity and reliability of the Rezum simulator.</p><p><strong>Methods: </strong>Seventeen candidates of different professions voluntarily participated in the Rezum simulation workshop. The simulator provides a variety of variable metrics and challenges. Each candidate performed three cases of different difficulty levels with three trials of each case. Validity was measured statistically through a one-way analysis of variance (ANOVA) test, and a p-value of < 0.05 was considered significant. Additional reliability tests were provided, including intraclass correlation coefficients, a Cronbach test (0.7 is considered acceptable), and standard error of measurement.</p><p><strong>Results: </strong>The ANOVA of total scores among candidates was significant (p = 0.029). Senior registrars and consultants had the highest total scores. Procedure times did not differ significantly among candidates (p = 0.169). The reliability test for the total score was 0.899 (0.831-0.942), with a standard error value of 2.75, a standard deviation of 8.67, and a Cronbach alpha value of 0.915.</p><p><strong>Conclusion: </strong>We confer the primer evidence of Rezum simulation as a valid, reliable simulator of most of its metrics.</p>","PeriodicalId":7074,"journal":{"name":"Acta Informatica Medica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10997172/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Informatica Medica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5455/aim.2024.32.82-87","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Simulations have revolutionized surgical training and are an invaluable adjunct tool for augmenting the proficiency of surgeon and patient safety. Before being included in a practical assessment process, simulators need to be using various validity inference frameworks.

Objective: We examine the construct validity and reliability of the Rezum simulator.

Methods: Seventeen candidates of different professions voluntarily participated in the Rezum simulation workshop. The simulator provides a variety of variable metrics and challenges. Each candidate performed three cases of different difficulty levels with three trials of each case. Validity was measured statistically through a one-way analysis of variance (ANOVA) test, and a p-value of < 0.05 was considered significant. Additional reliability tests were provided, including intraclass correlation coefficients, a Cronbach test (0.7 is considered acceptable), and standard error of measurement.

Results: The ANOVA of total scores among candidates was significant (p = 0.029). Senior registrars and consultants had the highest total scores. Procedure times did not differ significantly among candidates (p = 0.169). The reliability test for the total score was 0.899 (0.831-0.942), with a standard error value of 2.75, a standard deviation of 8.67, and a Cronbach alpha value of 0.915.

Conclusion: We confer the primer evidence of Rezum simulation as a valid, reliable simulator of most of its metrics.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
针对受训人员的 Rezum 模拟器的有效性。
背景:模拟已彻底改变了外科培训,是提高外科医生熟练程度和患者安全的宝贵辅助工具。在将模拟器纳入实际评估过程之前,需要使用各种有效性推论框架:我们研究了 Rezum 模拟器的结构效度和可靠性:17 名不同专业的考生自愿参加了 Rezum 模拟研讨会。模拟器提供了各种可变指标和挑战。每名候选人都进行了三个不同难度的案例,每个案例试验三次。通过单因子方差分析(ANOVA)测试对有效性进行统计测量,P 值小于 0.05 即为显著。此外,还提供了其他可靠性测试,包括类内相关系数、克朗巴赫测试(0.7 为可接受)和测量标准误差:候选人总分的方差分析结果显著(p = 0.029)。高级注册医师和顾问的总分最高。不同候选人的手术时间差异不大(p = 0.169)。总分的可靠性测试结果为 0.899(0.831-0.942),标准误为 2.75,标准差为 8.67,Cronbach alpha 值为 0.915:我们为 Rezum 模拟提供了初步证据,证明它是一种有效、可靠的模拟器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta Informatica Medica
Acta Informatica Medica Medicine-Medicine (all)
CiteScore
2.90
自引率
0.00%
发文量
37
期刊最新文献
Correlation Between Carotid Stenosis and Pulsatile Index Measured by Transcranial Doppler. Off pump Versus On pump Coronary Artery Bypass Grafting: Short-term Outcomes. Comparison of Osseointegration in Novel Laser-Textured and SLA Implants. How Far Goes the Un-ethic of the Authors Who Submit the Articles to the Journals, Or, Better to Say, Their "Scientific Insolence"? Significance of Detecting Antierythrocyte Antibodies in Pretransfusion Testing.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1