180- Versus 360-Degree Selective Laser Trabeculoplasty in Open Angle Glaucoma and Ocular Hypertension: A Systematic Review and Meta-Analysis.

IF 1.8 4区 医学 Q2 OPHTHALMOLOGY Journal of Glaucoma Pub Date : 2024-08-01 Epub Date: 2024-05-06 DOI:10.1097/IJG.0000000000002415
Daniel Zhu, Paras P Shah, Amanda Wong, Charles Zhang, Daniel Barmas-Alamdari, Michael Bouaziz, Andrew Tirsi, Celso Tello
{"title":"180- Versus 360-Degree Selective Laser Trabeculoplasty in Open Angle Glaucoma and Ocular Hypertension: A Systematic Review and Meta-Analysis.","authors":"Daniel Zhu, Paras P Shah, Amanda Wong, Charles Zhang, Daniel Barmas-Alamdari, Michael Bouaziz, Andrew Tirsi, Celso Tello","doi":"10.1097/IJG.0000000000002415","DOIUrl":null,"url":null,"abstract":"<p><strong>Prcis: </strong>This systematic review and meta-analysis found that 360-degree selective laser trabeculoplasty (SLT) is significantly more effective than 180-degree SLT at reducing intraocular pressure at 1-month and 1-year follow-ups without increased serious adverse event risk.</p><p><strong>Purpose: </strong>To determine the efficacy of 180- versus 360-degree selective laser trabeculoplasty (SLT) in adults with open angle glaucoma (OAG) and ocular hypertension (OHT).</p><p><strong>Methods: </strong>A systematic review was performed using PubMed, Embase, and Scopus databases, from 1995 to December 30, 2023, for studies comparing 180 and 360-degree SLT in adults with OAG and OHT (PROSPERO ID: CRD42024497832). Meta-analyses were performed to calculate nominal percent and raw reductions in intraocular pressure (IOP) between treatment groups at 1-month, 1-year, and 2-year follow-ups, as well as success rates, defined as a 20% or greater IOP reduction.</p><p><strong>Results: </strong>Nine studies with 1044 eyes were included; 491 received 180-degree SLT, and 553 received 360-degree SLT. At the 1-month follow-up, 360-degree SLT reduced IOP by 3.45% more (WMD=3.45; 95% CI: 2.02-4.88; P <0.00001) and 0.87 mm Hg more (WMD=0.87; 95% CI: 0.35-1.38; P =0.0010). At the 1-year follow-up, 360-degree SLT reduced IOP by 4.33% more (WMD=4.33; 95% CI: 2.35-6.32; P <0.0001) and 1.15 mm Hg more (WMD=1.15; 95% CI: 0.25-2.04; P =0.01). At 2 years of follow-up, 360-degree SLT reduced IOP by 4.86% more (WMD=4.86; 95% CI: -0.32, 10.0; P =0.07) and 1.25 mm Hg more (WMD=1.25; 95% CI: -0.29, 2.79; P =0.11); however, the difference was not statistically significant. Compared with 360-degree SLT, 180-degree SLT had a significantly lower success rate (OR=0.50; 95% CI: 0.35-0.72; P =0.0002). There was no difference in serious complications between interventions.</p><p><strong>Conclusions: </strong>360-degree SLT is more effective than 180-degree SLT at lowering IOP at 1-month and 1-year follow-ups as well as achieving successful IOP control without increased risk of serious complications.</p>","PeriodicalId":15938,"journal":{"name":"Journal of Glaucoma","volume":" ","pages":"566-575"},"PeriodicalIF":1.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Glaucoma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IJG.0000000000002415","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Prcis: This systematic review and meta-analysis found that 360-degree selective laser trabeculoplasty (SLT) is significantly more effective than 180-degree SLT at reducing intraocular pressure at 1-month and 1-year follow-ups without increased serious adverse event risk.

Purpose: To determine the efficacy of 180- versus 360-degree selective laser trabeculoplasty (SLT) in adults with open angle glaucoma (OAG) and ocular hypertension (OHT).

Methods: A systematic review was performed using PubMed, Embase, and Scopus databases, from 1995 to December 30, 2023, for studies comparing 180 and 360-degree SLT in adults with OAG and OHT (PROSPERO ID: CRD42024497832). Meta-analyses were performed to calculate nominal percent and raw reductions in intraocular pressure (IOP) between treatment groups at 1-month, 1-year, and 2-year follow-ups, as well as success rates, defined as a 20% or greater IOP reduction.

Results: Nine studies with 1044 eyes were included; 491 received 180-degree SLT, and 553 received 360-degree SLT. At the 1-month follow-up, 360-degree SLT reduced IOP by 3.45% more (WMD=3.45; 95% CI: 2.02-4.88; P <0.00001) and 0.87 mm Hg more (WMD=0.87; 95% CI: 0.35-1.38; P =0.0010). At the 1-year follow-up, 360-degree SLT reduced IOP by 4.33% more (WMD=4.33; 95% CI: 2.35-6.32; P <0.0001) and 1.15 mm Hg more (WMD=1.15; 95% CI: 0.25-2.04; P =0.01). At 2 years of follow-up, 360-degree SLT reduced IOP by 4.86% more (WMD=4.86; 95% CI: -0.32, 10.0; P =0.07) and 1.25 mm Hg more (WMD=1.25; 95% CI: -0.29, 2.79; P =0.11); however, the difference was not statistically significant. Compared with 360-degree SLT, 180-degree SLT had a significantly lower success rate (OR=0.50; 95% CI: 0.35-0.72; P =0.0002). There was no difference in serious complications between interventions.

Conclusions: 360-degree SLT is more effective than 180-degree SLT at lowering IOP at 1-month and 1-year follow-ups as well as achieving successful IOP control without increased risk of serious complications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
180° 与 360° 选择性激光小梁成形术治疗开角型青光眼和眼压过高:系统回顾与元分析》。
摘要目的:确定 180°与 360°选择性激光小梁成形术(SLT)在成人开角型青光眼(OAG)和眼压过高(OHT)患者中的疗效:使用 PubMed、Embase 和 Scopus 数据库对 1995 年至 2023 年 12 月 30 日期间比较 180° 和 360° SLT 治疗成人开角型青光眼(OAG)和眼压过高(OHT)的研究进行了系统综述(PROSPERO ID:CRD42024497832)。进行了元分析,以计算治疗组在一个月、一年和两年随访时眼压降低的名义百分比和原始百分比,以及成功率(定义为眼压降低 20% 或以上):九项研究共纳入了 1044 只眼睛,其中 491 只接受了 180°SLT 治疗,553 只接受了 360° SLT 治疗。在一个月的随访中,360° SLT 降低的眼压比 180° SLT 高出 3.45% (WMD=3.45;95% CI:2.02-4.88;PC 结论:在一个月和一年的随访中,360° SLT 比 180° SLT 更能有效降低眼压,并能成功控制眼压,同时不会增加严重并发症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Glaucoma
Journal of Glaucoma 医学-眼科学
CiteScore
4.20
自引率
10.00%
发文量
330
审稿时长
4-8 weeks
期刊介绍: The Journal of Glaucoma is a peer reviewed journal addressing the spectrum of issues affecting definition, diagnosis, and management of glaucoma and providing a forum for lively and stimulating discussion of clinical, scientific, and socioeconomic factors affecting care of glaucoma patients.
期刊最新文献
24-Hour Intraocular Pressure Rhythms and Measurement Frequency in Glaucoma Using an Intraocular Telemetry Sensor. Discrepancy Between Real-World Objective Functioning and Subjective Quality of Life in Visually Impaired Adults. Evaluation of Glaucoma Treatment Information on Social Media Using Large Language Models. Predictors of Glaucoma Progression After Acute Primary Angle Closure. Incidence and Factors Associated With Postoperative Intraocular Pressure Spike Following Micropulse Transscleral Laser Therapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1