{"title":"180- Versus 360-Degree Selective Laser Trabeculoplasty in Open Angle Glaucoma and Ocular Hypertension: A Systematic Review and Meta-Analysis.","authors":"Daniel Zhu, Paras P Shah, Amanda Wong, Charles Zhang, Daniel Barmas-Alamdari, Michael Bouaziz, Andrew Tirsi, Celso Tello","doi":"10.1097/IJG.0000000000002415","DOIUrl":null,"url":null,"abstract":"<p><strong>Prcis: </strong>This systematic review and meta-analysis found that 360-degree selective laser trabeculoplasty (SLT) is significantly more effective than 180-degree SLT at reducing intraocular pressure at 1-month and 1-year follow-ups without increased serious adverse event risk.</p><p><strong>Purpose: </strong>To determine the efficacy of 180- versus 360-degree selective laser trabeculoplasty (SLT) in adults with open angle glaucoma (OAG) and ocular hypertension (OHT).</p><p><strong>Methods: </strong>A systematic review was performed using PubMed, Embase, and Scopus databases, from 1995 to December 30, 2023, for studies comparing 180 and 360-degree SLT in adults with OAG and OHT (PROSPERO ID: CRD42024497832). Meta-analyses were performed to calculate nominal percent and raw reductions in intraocular pressure (IOP) between treatment groups at 1-month, 1-year, and 2-year follow-ups, as well as success rates, defined as a 20% or greater IOP reduction.</p><p><strong>Results: </strong>Nine studies with 1044 eyes were included; 491 received 180-degree SLT, and 553 received 360-degree SLT. At the 1-month follow-up, 360-degree SLT reduced IOP by 3.45% more (WMD=3.45; 95% CI: 2.02-4.88; P <0.00001) and 0.87 mm Hg more (WMD=0.87; 95% CI: 0.35-1.38; P =0.0010). At the 1-year follow-up, 360-degree SLT reduced IOP by 4.33% more (WMD=4.33; 95% CI: 2.35-6.32; P <0.0001) and 1.15 mm Hg more (WMD=1.15; 95% CI: 0.25-2.04; P =0.01). At 2 years of follow-up, 360-degree SLT reduced IOP by 4.86% more (WMD=4.86; 95% CI: -0.32, 10.0; P =0.07) and 1.25 mm Hg more (WMD=1.25; 95% CI: -0.29, 2.79; P =0.11); however, the difference was not statistically significant. Compared with 360-degree SLT, 180-degree SLT had a significantly lower success rate (OR=0.50; 95% CI: 0.35-0.72; P =0.0002). There was no difference in serious complications between interventions.</p><p><strong>Conclusions: </strong>360-degree SLT is more effective than 180-degree SLT at lowering IOP at 1-month and 1-year follow-ups as well as achieving successful IOP control without increased risk of serious complications.</p>","PeriodicalId":15938,"journal":{"name":"Journal of Glaucoma","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Glaucoma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IJG.0000000000002415","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Prcis: This systematic review and meta-analysis found that 360-degree selective laser trabeculoplasty (SLT) is significantly more effective than 180-degree SLT at reducing intraocular pressure at 1-month and 1-year follow-ups without increased serious adverse event risk.

Purpose: To determine the efficacy of 180- versus 360-degree selective laser trabeculoplasty (SLT) in adults with open angle glaucoma (OAG) and ocular hypertension (OHT).

Methods: A systematic review was performed using PubMed, Embase, and Scopus databases, from 1995 to December 30, 2023, for studies comparing 180 and 360-degree SLT in adults with OAG and OHT (PROSPERO ID: CRD42024497832). Meta-analyses were performed to calculate nominal percent and raw reductions in intraocular pressure (IOP) between treatment groups at 1-month, 1-year, and 2-year follow-ups, as well as success rates, defined as a 20% or greater IOP reduction.

Results: Nine studies with 1044 eyes were included; 491 received 180-degree SLT, and 553 received 360-degree SLT. At the 1-month follow-up, 360-degree SLT reduced IOP by 3.45% more (WMD=3.45; 95% CI: 2.02-4.88; P <0.00001) and 0.87 mm Hg more (WMD=0.87; 95% CI: 0.35-1.38; P =0.0010). At the 1-year follow-up, 360-degree SLT reduced IOP by 4.33% more (WMD=4.33; 95% CI: 2.35-6.32; P <0.0001) and 1.15 mm Hg more (WMD=1.15; 95% CI: 0.25-2.04; P =0.01). At 2 years of follow-up, 360-degree SLT reduced IOP by 4.86% more (WMD=4.86; 95% CI: -0.32, 10.0; P =0.07) and 1.25 mm Hg more (WMD=1.25; 95% CI: -0.29, 2.79; P =0.11); however, the difference was not statistically significant. Compared with 360-degree SLT, 180-degree SLT had a significantly lower success rate (OR=0.50; 95% CI: 0.35-0.72; P =0.0002). There was no difference in serious complications between interventions.

Conclusions: 360-degree SLT is more effective than 180-degree SLT at lowering IOP at 1-month and 1-year follow-ups as well as achieving successful IOP control without increased risk of serious complications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
180° 与 360° 选择性激光小梁成形术治疗开角型青光眼和眼压过高:系统回顾与元分析》。
摘要目的:确定 180°与 360°选择性激光小梁成形术(SLT)在成人开角型青光眼(OAG)和眼压过高(OHT)患者中的疗效:使用 PubMed、Embase 和 Scopus 数据库对 1995 年至 2023 年 12 月 30 日期间比较 180° 和 360° SLT 治疗成人开角型青光眼(OAG)和眼压过高(OHT)的研究进行了系统综述(PROSPERO ID:CRD42024497832)。进行了元分析,以计算治疗组在一个月、一年和两年随访时眼压降低的名义百分比和原始百分比,以及成功率(定义为眼压降低 20% 或以上):九项研究共纳入了 1044 只眼睛,其中 491 只接受了 180°SLT 治疗,553 只接受了 360° SLT 治疗。在一个月的随访中,360° SLT 降低的眼压比 180° SLT 高出 3.45% (WMD=3.45;95% CI:2.02-4.88;PC 结论:在一个月和一年的随访中,360° SLT 比 180° SLT 更能有效降低眼压,并能成功控制眼压,同时不会增加严重并发症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Glaucoma
Journal of Glaucoma 医学-眼科学
CiteScore
4.20
自引率
10.00%
发文量
330
审稿时长
4-8 weeks
期刊介绍: The Journal of Glaucoma is a peer reviewed journal addressing the spectrum of issues affecting definition, diagnosis, and management of glaucoma and providing a forum for lively and stimulating discussion of clinical, scientific, and socioeconomic factors affecting care of glaucoma patients.
期刊最新文献
Association Between Migraine and Open-Angle Glaucoma: A Twelve-Year Nationwide Retrospective Korean Cohort Study. Comparison of Elisar-Fast and Sita-Fast Strategy for Visual Field Assessment in Glaucoma. Outcomes of Trabeculectomy and Predictors of Success in Patients of African Ancestry with Primary Open Angle Glaucoma. Outcomes of a Second Ahmed Glaucoma Implant With Mitomycin-C in Pediatric Glaucoma After Initial Valve Failure. Outcomes of Phacoemulsification With or Without Kahook Dual Blade Goniotomy for Glaucoma Patients With Cataract.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1