Pulmonary strain and end-expiratory lung volume during apnea test: a comparative analysis using electrical impedance tomography.
IF 0.6 4区 医学Q3 MEDICINE, GENERAL & INTERNALMedicina-buenos AiresPub Date : 2024-01-01
Ignacio Fernández Ceballos, Joaquín Ems, Emilio Steinberg, Juan M Nuñez Silveira, Micaela B Hornos, Melany Berdiñas Anfuso, Carlos Videla, Nicolás M Ciarrocchi, Indalecio Carboni Bisso, Marcos Las Heras
{"title":"Pulmonary strain and end-expiratory lung volume during apnea test: a comparative analysis using electrical impedance tomography.","authors":"Ignacio Fernández Ceballos, Joaquín Ems, Emilio Steinberg, Juan M Nuñez Silveira, Micaela B Hornos, Melany Berdiñas Anfuso, Carlos Videla, Nicolás M Ciarrocchi, Indalecio Carboni Bisso, Marcos Las Heras","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The apnea test, employed for brain death assessment, aims to demonstrate the absence of respiratory drive due to hypercapnia. The tracheal oxygen insufflation apnea test mode (I-AT) involves disconnecting the patient from invasive mechanical ventilation (iMV) for approximately 8 minutes while maintaining oxygenation. This test supports the diagnosis of brain death based on a specified increase in PaCO2. Common complications include hypoxemia and hemodynamic instability, and lung collapse-induced reduction in end-expiratory lung volume (EELV). In our case series utilizing electrical impedance tomography (EIT), we observed that continuous positive airway pressure during the apnea test (CPAP-AT) effectively mitigated lung collapse. This resulted in improved pulmonary strain compared to the disconnection of iMV. These findings suggest the potential benefits of routine CPAP-AT, particularly for potential lung donors, emphasizing the relevance of our study in providing quantitative insights into EELV loss and its association with pulmonary strain and potential lung injury.</p>","PeriodicalId":18419,"journal":{"name":"Medicina-buenos Aires","volume":"84 2","pages":"359-363"},"PeriodicalIF":0.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina-buenos Aires","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
The apnea test, employed for brain death assessment, aims to demonstrate the absence of respiratory drive due to hypercapnia. The tracheal oxygen insufflation apnea test mode (I-AT) involves disconnecting the patient from invasive mechanical ventilation (iMV) for approximately 8 minutes while maintaining oxygenation. This test supports the diagnosis of brain death based on a specified increase in PaCO2. Common complications include hypoxemia and hemodynamic instability, and lung collapse-induced reduction in end-expiratory lung volume (EELV). In our case series utilizing electrical impedance tomography (EIT), we observed that continuous positive airway pressure during the apnea test (CPAP-AT) effectively mitigated lung collapse. This resulted in improved pulmonary strain compared to the disconnection of iMV. These findings suggest the potential benefits of routine CPAP-AT, particularly for potential lung donors, emphasizing the relevance of our study in providing quantitative insights into EELV loss and its association with pulmonary strain and potential lung injury.