Lower Limb Malrotation following Minimally Invasive Plating in Distal Tibia Fractures.

IF 0.6 Q4 ORTHOPEDICS Malaysian Orthopaedic Journal Pub Date : 2024-03-01 DOI:10.5704/MOJ.2403.018
Wmq Yap, J W Ng, Mjjr Lee, Ebk Kwek
{"title":"Lower Limb Malrotation following Minimally Invasive Plating in Distal Tibia Fractures.","authors":"Wmq Yap, J W Ng, Mjjr Lee, Ebk Kwek","doi":"10.5704/MOJ.2403.018","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Minimally invasive percutaneousosteosynthesis (MIPO) plating techniques havedemonstrated good outcomes in the treatment of distal tibia fractures. Early arthritis and functional impairment mayoccur if length and rotation are not restored. This study aims to determine the incidence and severity of tibia malrotation following MIPO plating of isolated unilateral distal tibia fractures, defined as torsional difference of greater than 10° as compared to the contralateral limb and whether the degree of malrotation affects functional outcomes scores.</p><p><strong>Materials and methods: </strong>This was a level 2 prospective cohort study. All patients with fractures of the distal tibia who underwent surgical fixation with the exclusion ofpatients with polytrauma, neurovascular injuries or pre-existing disabilities were recruited. Patients underwent MIPO plating followed by a post-operative ComputedTomography (CT) scan of bilateral lower limbs. AOFAS ankle-hindfoot score was recorded at six months and one year follow-up.</p><p><strong>Results: </strong>A total of 24 patients (28 to 83 years old) were recruited. Nineteen patients obtained CT scans. Nine of the 19 patients (47.3%) had tibia malrotation. The mean tibia malrotation angle was 10.3° (0° - 45°). The average AOFAS scores was 82.4 and 84.3 at 6 months and 1 year follow-up. Degree of CT malrotation was not significantly associated with AOFAS scores at 6 month (spearman rho -0.386) and 1 year (spearman rho -0.343).</p><p><strong>Conclusions: </strong>Tibia malrotation following MIPO plating of distal tibia fractures is common, with an incidence of 47.3% and an average malrotation angle of 10.3°. The degree of malrotation does not appear to have significant mid-term functional impact on the patient.</p>","PeriodicalId":45241,"journal":{"name":"Malaysian Orthopaedic Journal","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11023353/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Orthopaedic Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5704/MOJ.2403.018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Minimally invasive percutaneousosteosynthesis (MIPO) plating techniques havedemonstrated good outcomes in the treatment of distal tibia fractures. Early arthritis and functional impairment mayoccur if length and rotation are not restored. This study aims to determine the incidence and severity of tibia malrotation following MIPO plating of isolated unilateral distal tibia fractures, defined as torsional difference of greater than 10° as compared to the contralateral limb and whether the degree of malrotation affects functional outcomes scores.

Materials and methods: This was a level 2 prospective cohort study. All patients with fractures of the distal tibia who underwent surgical fixation with the exclusion ofpatients with polytrauma, neurovascular injuries or pre-existing disabilities were recruited. Patients underwent MIPO plating followed by a post-operative ComputedTomography (CT) scan of bilateral lower limbs. AOFAS ankle-hindfoot score was recorded at six months and one year follow-up.

Results: A total of 24 patients (28 to 83 years old) were recruited. Nineteen patients obtained CT scans. Nine of the 19 patients (47.3%) had tibia malrotation. The mean tibia malrotation angle was 10.3° (0° - 45°). The average AOFAS scores was 82.4 and 84.3 at 6 months and 1 year follow-up. Degree of CT malrotation was not significantly associated with AOFAS scores at 6 month (spearman rho -0.386) and 1 year (spearman rho -0.343).

Conclusions: Tibia malrotation following MIPO plating of distal tibia fractures is common, with an incidence of 47.3% and an average malrotation angle of 10.3°. The degree of malrotation does not appear to have significant mid-term functional impact on the patient.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胫骨远端骨折微创钢板术后下肢旋转不良。
导言:微创经皮骨结合(MIPO)钢板技术在治疗胫骨远端骨折方面取得了良好的疗效。如果不能恢复长度和旋转,可能会出现早期关节炎和功能障碍。本研究旨在确定孤立性单侧胫骨远端骨折MIPO钢板固定后胫骨旋转不良的发生率和严重程度,即与对侧肢体相比扭转差大于10°,以及旋转不良的程度是否会影响功能结果评分:这是一项二级前瞻性队列研究。所有接受手术固定的胫骨远端骨折患者均被纳入研究,但排除了多发性创伤、神经血管损伤或原有残疾的患者。患者接受 MIPO 钢板固定术,术后进行双侧下肢计算机断层扫描(CT)。随访六个月和一年时记录 AOFAS 踝关节-后足评分:共招募了 24 名患者(28 至 83 岁)。19 名患者接受了 CT 扫描。19名患者中有9名(47.3%)存在胫骨旋转不良。平均胫骨旋转角度为 10.3°(0° - 45°)。随访 6 个月和 1 年后,AOFAS 平均评分分别为 82.4 分和 84.3 分。CT错位程度与6个月和1年的AOFAS评分无明显相关性(spearman rho -0.386)和(spearman rho -0.343):胫骨远端骨折MIPO钢板术后胫骨旋转不良很常见,发生率为47.3%,平均旋转不良角度为10.3°。旋转不良的程度似乎不会对患者的中期功能产生重大影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
104
审稿时长
24 weeks
期刊介绍: The Malaysian Orthopaedic Journal is a peer-reviewed journal that publishes original papers and case reports three times a year in both printed and electronic version. The purpose of MOJ is to disseminate new knowledge and provide updates in Orthopaedics, trauma and musculoskeletal research. It is an Open Access journal that does not require processing fee or article processing charge from the authors. The Malaysian Orthopaedic Journal is the official journal of Malaysian Orthopaedic Association (MOA) and ASEAN Orthopaedic Association (AOA).
期刊最新文献
Bibliometric Analysis of Malaysian Orthopaedic Journal using Scopus Database. Complete Suprapatellar Plica in a Handball Player: A Case Report. Creating Novel Standards for Datapoints on an Elective Orthopaedic Theatre List Document. Deafening Silence of Malaysian Medical and Surgical Fraternities to the Gaza Genocide. Functional Outcomes and a Review of Management Options for Revision Shoulder Arthroplasty.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1