Low-dose warfarin with a novel mechanical aortic valve: Interim registry results at 5-year follow-up

IF 4.9 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Thoracic and Cardiovascular Surgery Pub Date : 2024-12-01 DOI:10.1016/j.jtcvs.2024.04.017
Marc W. Gerdisch MD , Robert Carl Hagberg MD , Michael J. Perchinsky MD , Mark Joseph MD , Aung Y. Oo MD , Mahmoud Loubani MD , Geoffrey M. Tsang MD , Joseph Zacharias MD , Mohanakrishnan Sathyamoorthy MD
{"title":"Low-dose warfarin with a novel mechanical aortic valve: Interim registry results at 5-year follow-up","authors":"Marc W. Gerdisch MD ,&nbsp;Robert Carl Hagberg MD ,&nbsp;Michael J. Perchinsky MD ,&nbsp;Mark Joseph MD ,&nbsp;Aung Y. Oo MD ,&nbsp;Mahmoud Loubani MD ,&nbsp;Geoffrey M. Tsang MD ,&nbsp;Joseph Zacharias MD ,&nbsp;Mohanakrishnan Sathyamoorthy MD","doi":"10.1016/j.jtcvs.2024.04.017","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div>To evaluate whether warfarin targeted at an international normalized ratio of 1.8 (range, 1.5-2.0) after On-X mechanical aortic valve implant is safe for all patients.</div></div><div><h3>Methods</h3><div>This prospective, observational clinical registry assessed adverse event rates in adult patients receiving low-dose warfarin (target international normalized ratio, 1.8; range, 1.5-2.0) plus daily aspirin (75-100 mg) during a 5-year period after On-X aortic valve implant. The primary end point is the combined rate of major bleeding, valve thrombosis, and thromboembolism overall and in 4 subgroups. The comparator is the Prospective Randomized On-X Anticoagulation Trial control group patients on standard-dose warfarin (international normalized ratio, 2.0-3.0) plus aspirin 81 milligrams daily.</div></div><div><h3>Results</h3><div>A total of 510 patients were recruited at 23 centers in the United States, United Kingdom, and Canada between November 2015 and January 2022. This interim analysis includes 229 patients scheduled to complete 5-year follow-up by August 16, 2023. The linearized occurrence rate (in percent per patient-year) of the primary composite end point of major bleeding, valve thrombosis, and thromboembolism is 1.83% compared with 5.39% (95% confidence interval, 4.12%-6.93%) in the comparator group. Results are consistent in clinic-monitored and home-monitored patients and in those at high risk for thromboembolism. Major bleeding and total bleeding were reduced by 87% and 71%, respectively, versus the comparator group, without an increase in thromboembolic events.</div></div><div><h3>Conclusions</h3><div>Interim results support the continued safety of the On-X aortic mechanical valve with a target international normalized ratio of 1.8 plus low-dose aspirin through 5 years after implant, with or without home monitoring.</div></div>","PeriodicalId":49975,"journal":{"name":"Journal of Thoracic and Cardiovascular Surgery","volume":"168 6","pages":"Pages 1645-1655.e6"},"PeriodicalIF":4.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022522324003593","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To evaluate whether warfarin targeted at an international normalized ratio of 1.8 (range, 1.5-2.0) after On-X mechanical aortic valve implant is safe for all patients.

Methods

This prospective, observational clinical registry assessed adverse event rates in adult patients receiving low-dose warfarin (target international normalized ratio, 1.8; range, 1.5-2.0) plus daily aspirin (75-100 mg) during a 5-year period after On-X aortic valve implant. The primary end point is the combined rate of major bleeding, valve thrombosis, and thromboembolism overall and in 4 subgroups. The comparator is the Prospective Randomized On-X Anticoagulation Trial control group patients on standard-dose warfarin (international normalized ratio, 2.0-3.0) plus aspirin 81 milligrams daily.

Results

A total of 510 patients were recruited at 23 centers in the United States, United Kingdom, and Canada between November 2015 and January 2022. This interim analysis includes 229 patients scheduled to complete 5-year follow-up by August 16, 2023. The linearized occurrence rate (in percent per patient-year) of the primary composite end point of major bleeding, valve thrombosis, and thromboembolism is 1.83% compared with 5.39% (95% confidence interval, 4.12%-6.93%) in the comparator group. Results are consistent in clinic-monitored and home-monitored patients and in those at high risk for thromboembolism. Major bleeding and total bleeding were reduced by 87% and 71%, respectively, versus the comparator group, without an increase in thromboembolic events.

Conclusions

Interim results support the continued safety of the On-X aortic mechanical valve with a target international normalized ratio of 1.8 plus low-dose aspirin through 5 years after implant, with or without home monitoring.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低剂量华法林与新型机械主动脉瓣:随访 5 年的中期登记结果。
目的评估所有患者在接受 On-X 机械主动脉瓣植入术后,以国际正常化比率 1.8(范围 1.5-2.0)为目标的华法林是否安全:这项前瞻性、观察性临床登记评估了接受小剂量华法林(目标国际正常化比率 1.8,范围 1.5-2.0)加每日阿司匹林(75-100 毫克)治疗的成年患者在 On-X 主动脉瓣植入术后 5 年内的不良事件发生率。主要终点是总体和 4 个亚组的大出血、瓣膜血栓和血栓栓塞综合发生率。对比组为前瞻性随机 On-X 抗凝试验对照组,患者每天服用标准剂量华法林(国际正常化比率 2.0-3.0)加阿司匹林 81 毫克:2015年11月至2022年1月期间,美国、英国和加拿大的23个中心共招募了510名患者。本次中期分析包括计划在2023年8月16日前完成5年随访的229名患者。大出血、瓣膜血栓形成和血栓栓塞等主要复合终点的线性化发生率(每患者年百分比)为 1.83%,而对比组为 5.39%(95% 置信区间为 4.12%-6.93%)。诊所监测组和家庭监测组以及血栓栓塞高危患者的结果一致。与对照组相比,大出血和总出血量分别减少了87%和71%,但血栓栓塞事件并未增加:中期研究结果表明,无论是否进行家庭监测,On-X 主动脉瓣机械瓣膜在植入后 5 年内,国际正常化比率目标值为 1.8,并服用小剂量阿司匹林,仍具有持续的安全性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
11.20
自引率
10.00%
发文量
1079
审稿时长
68 days
期刊介绍: The Journal of Thoracic and Cardiovascular Surgery presents original, peer-reviewed articles on diseases of the heart, great vessels, lungs and thorax with emphasis on surgical interventions. An official publication of The American Association for Thoracic Surgery and The Western Thoracic Surgical Association, the Journal focuses on techniques and developments in acquired cardiac surgery, congenital cardiac repair, thoracic procedures, heart and lung transplantation, mechanical circulatory support and other procedures.
期刊最新文献
Outcomes of thoracoabdominal aortic aneurysm repair in patients with a previous myocardial infarction. Unexpected impact of preoperative anemia in low-risk isolated coronary artery bypass grafting or single-valve surgical patients: Do not overlook these patients in anemia management! Commentary: Incremental improvement is better than no improvement! Natural history of the distal aorta following elective root replacement in patients with Marfan syndrome. Durability of bovine pericardial mitral bioprosthesis based on Heart Valve Collaboratory echocardiographic criteria.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1