{"title":"Light Polymerization through Glass-ceramics: Influence of Light-polymerizing Unit's Emitted Power and Restoration Parameters (Shade, Translucency, and Thickness) on Transmitted Radiant Power.","authors":"Ra'fat I Farah, Ibrahim A Alblihed, Alhareth A Aljuoie, Bandar Alresheedi","doi":"10.4103/ccd.ccd_124_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This <i>in vitro</i> study assessed light transmission through ceramic discs varying in shade, translucency, and thickness using light-polymerizing units with different radiant power/flux (RP) outputs.</p><p><strong>Methods: </strong>Disc-shaped specimens (0.5 mm, 1.0 mm, and 2.0 mm) were made from high and low-translucency glass-ceramic ingots (IPS e.max Press) in shades A1 and A4, totaling 60 discs. Two light-polymerizing units with different power outputs were used, and their emission spectra were verified. The transmitted RP values for each ceramic specimen were measured and irradiance and radiant energy influx were calculated. Differences between the light-polymerizing units and the influence of the three ceramic parameters were evaluated using an independent-samples <i>t</i>-test and three-way analysis of variance (ANOVA) tests (α = 0.05).</p><p><strong>Results: </strong>A statistically significant difference was observed in the mean transmitted RP values between the two light-polymerizing units. Furthermore, the three-way ANOVA test showed a significant effect of shade, translucency, and thickness, as well as a significant interaction between each pair of variables and all three variables on the transmitted RP (<i>P</i> < 0.05).</p><p><strong>Conclusions: </strong>Despite the significant attenuation in the transmitted RP, especially in ceramics with higher shade chromaticity and thickness and lower translucency, the calculated minimal irradiance values for both light-polymerizing units (their emitted power ≥ 500 mW) were greater than the minimum recommended irradiance threshold (100 mW/cm<sup>2</sup>). However, the exposure duration needs to be increased to provide the resin with sufficient radiant exposure for adequate polymerization.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11068246/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ccd.ccd_124_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This in vitro study assessed light transmission through ceramic discs varying in shade, translucency, and thickness using light-polymerizing units with different radiant power/flux (RP) outputs.

Methods: Disc-shaped specimens (0.5 mm, 1.0 mm, and 2.0 mm) were made from high and low-translucency glass-ceramic ingots (IPS e.max Press) in shades A1 and A4, totaling 60 discs. Two light-polymerizing units with different power outputs were used, and their emission spectra were verified. The transmitted RP values for each ceramic specimen were measured and irradiance and radiant energy influx were calculated. Differences between the light-polymerizing units and the influence of the three ceramic parameters were evaluated using an independent-samples t-test and three-way analysis of variance (ANOVA) tests (α = 0.05).

Results: A statistically significant difference was observed in the mean transmitted RP values between the two light-polymerizing units. Furthermore, the three-way ANOVA test showed a significant effect of shade, translucency, and thickness, as well as a significant interaction between each pair of variables and all three variables on the transmitted RP (P < 0.05).

Conclusions: Despite the significant attenuation in the transmitted RP, especially in ceramics with higher shade chromaticity and thickness and lower translucency, the calculated minimal irradiance values for both light-polymerizing units (their emitted power ≥ 500 mW) were greater than the minimum recommended irradiance threshold (100 mW/cm2). However, the exposure duration needs to be increased to provide the resin with sufficient radiant exposure for adequate polymerization.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
通过玻璃陶瓷进行光聚合:光聚合装置的发射功率和修复参数(阴影、半透明度和厚度)对透射辐射功率的影响。
背景:这项体外研究使用具有不同辐射功率/流量(RP)输出的光聚合装置,评估了不同色调、半透明度和厚度的陶瓷圆盘的透光率:圆盘状试样(0.5 毫米、1.0 毫米和 2.0 毫米)由高透光度和低透光度玻璃陶瓷锭(IPS e.max Press)制成,色调为 A1 和 A4,共 60 个圆盘。使用了两种不同功率输出的光聚合装置,并对其发射光谱进行了验证。测量了每个陶瓷试样的透射 RP 值,并计算了辐照度和辐射能流入量。使用独立样本 t 检验和三方方差分析 (ANOVA) 检验(α = 0.05)评估了光聚合装置之间的差异和三个陶瓷参数的影响:结果:两种光聚合装置的平均透射 RP 值在统计学上存在明显差异。此外,三方方差分析测试表明,遮光率、半透明度和厚度对透射 RP 有显著影响,每对变量与所有三个变量之间也有显著的交互作用(P < 0.05):尽管透射 RP 有明显的衰减,特别是在色度和厚度较高、半透明度较低的陶瓷中,但两种光聚合装置计算出的最小辐照度值(其发射功率≥ 500 mW)都大于推荐的最小辐照度阈值(100 mW/cm2)。不过,需要延长照射时间,以便为树脂提供足够的辐射照射,使其充分聚合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1