Device-related outcomes following hypoglossal nerve stimulator implantation.

IF 2.9 3区 医学 Q1 CLINICAL NEUROLOGY Journal of Clinical Sleep Medicine Pub Date : 2024-09-01 DOI:10.5664/jcsm.11176
Annie E Moroco, Zhikui Wei, Israel Byrd, Andrea Rasmussen, Eugene G Chio, Ryan J Soose, Phillip Huyett, Armin Steffen, Clemens Heiser, Maurits S Boon, Colin T Huntley
{"title":"Device-related outcomes following hypoglossal nerve stimulator implantation.","authors":"Annie E Moroco, Zhikui Wei, Israel Byrd, Andrea Rasmussen, Eugene G Chio, Ryan J Soose, Phillip Huyett, Armin Steffen, Clemens Heiser, Maurits S Boon, Colin T Huntley","doi":"10.5664/jcsm.11176","DOIUrl":null,"url":null,"abstract":"<p><strong>Study objectives: </strong>Hypoglossal nerve stimulation (HGNS) has been widely used to treat obstructive sleep apnea in selected patients. Here we evaluate rates of revision and explant related to HGNS implantation and assess types of adverse events contributing to revision and explant.</p><p><strong>Methods: </strong>Postmarket surveillance data for HGNS implanted between January 1, 2018 and March 31, 2022, were collected. Event rates and risk were calculated using the postmarket surveillance event counts and sales volume over the same period. Indications were categorized for analysis. Descriptive statistics were reported and freedom from explant or revision curves were grouped by year of implantation.</p><p><strong>Results: </strong>Of the 20,881 HGNS implants assessed, rates of explant and revision within the first year were 0.723% and 1.542%, respectively. The most common indication for explant was infection (0.378%) and for revision was surgical correction (0.680%). Of the 5,820 devices with 3-year postimplantation data, the rate of explant was 2.680% and of revision was 3.557%. During this same interval, elective removal (1.478%) was the most common indication, and for revisions, surgical correction (1.134%).</p><p><strong>Conclusions: </strong>The efficacy of HGNS is comparable in the real world setting to published clinical trial data. Rates of explant and revision are low, supporting a satisfactory safety profile for this technology.</p><p><strong>Citation: </strong>Moroco AE, Wei Z, Byrd I, et al. Device-related outcomes following hypoglossal nerve stimulator implantation. <i>J Clin Sleep Med</i>. 2024;20(9):1497-1503.</p>","PeriodicalId":50233,"journal":{"name":"Journal of Clinical Sleep Medicine","volume":" ","pages":"1497-1503"},"PeriodicalIF":2.9000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11367714/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Sleep Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5664/jcsm.11176","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Study objectives: Hypoglossal nerve stimulation (HGNS) has been widely used to treat obstructive sleep apnea in selected patients. Here we evaluate rates of revision and explant related to HGNS implantation and assess types of adverse events contributing to revision and explant.

Methods: Postmarket surveillance data for HGNS implanted between January 1, 2018 and March 31, 2022, were collected. Event rates and risk were calculated using the postmarket surveillance event counts and sales volume over the same period. Indications were categorized for analysis. Descriptive statistics were reported and freedom from explant or revision curves were grouped by year of implantation.

Results: Of the 20,881 HGNS implants assessed, rates of explant and revision within the first year were 0.723% and 1.542%, respectively. The most common indication for explant was infection (0.378%) and for revision was surgical correction (0.680%). Of the 5,820 devices with 3-year postimplantation data, the rate of explant was 2.680% and of revision was 3.557%. During this same interval, elective removal (1.478%) was the most common indication, and for revisions, surgical correction (1.134%).

Conclusions: The efficacy of HGNS is comparable in the real world setting to published clinical trial data. Rates of explant and revision are low, supporting a satisfactory safety profile for this technology.

Citation: Moroco AE, Wei Z, Byrd I, et al. Device-related outcomes following hypoglossal nerve stimulator implantation. J Clin Sleep Med. 2024;20(9):1497-1503.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
舌下神经刺激器植入术后与设备相关的结果。
研究目的:舌下神经刺激(HGNS)已被广泛用于治疗部分患者的阻塞性睡眠呼吸暂停。在此,我们评估了与 HGNS 植入相关的翻修和拆卸率,并评估了导致翻修和拆卸的不良事件类型:收集了 2018 年 1 月 1 日至 2022 年 3 月 31 日期间植入的 HGNS 的上市后监测数据。使用上市后监测事件计数和同期销售量计算事件发生率和风险。分析时对适应症进行了分类。报告了描述性统计数字,并按植入年份对无切除或翻修曲线进行了分组:结果:在接受评估的 20,881 例 HGNS 植入物中,第一年内的更换率和翻修率分别为 0.723% 和 1.542%。最常见的移植适应症是感染(0.378%),最常见的翻修适应症是手术矫正(0.680%)。在有植入后三年数据的 5,820 台设备中,取出率为 2.680%,翻修率为 3.557%。在相同的时间间隔内,选择性摘除(1.478%)是最常见的适应症,翻修则是手术矫正(1.134%):结论:HGNS 在现实环境中的疗效与已公布的临床试验数据相当。结论:在现实世界中,HGNS 的疗效与已公布的临床试验数据相当。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.20
自引率
7.00%
发文量
321
审稿时长
1 months
期刊介绍: Journal of Clinical Sleep Medicine focuses on clinical sleep medicine. Its emphasis is publication of papers with direct applicability and/or relevance to the clinical practice of sleep medicine. This includes clinical trials, clinical reviews, clinical commentary and debate, medical economic/practice perspectives, case series and novel/interesting case reports. In addition, the journal will publish proceedings from conferences, workshops and symposia sponsored by the American Academy of Sleep Medicine or other organizations related to improving the practice of sleep medicine.
期刊最新文献
Validation of an artificial intelligence based single-channel photoplethysmography home sleep apnea test. Perinatal stressors and sleep quality in adolescents: a Brazilian birth cohort study. Steam-assisted respiratory muscle training may improve sleep quality in mild-to-moderate obstructive sleep apnea: a pilot polysomnography study. Risk of influenza and COVID-19 illness and pediatric obstructive sleep apnea: a TriNetX cohort with 5-year follow-up. Captured on camera: nocturnal self-observation as a driver of improved PAP adherence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1