Modification of Humeral Component Results in Increased Impingement Free Range of Motion in a Reverse Shoulder Arthroplasty Model.

Journal of shoulder and elbow arthroplasty Pub Date : 2024-04-15 eCollection Date: 2024-01-01 DOI:10.1177/24715492241237034
Dalton Dale Schroeder, Alexander Borsgard, Timothy Lee Rossman, Cory Michael Stewart
{"title":"Modification of Humeral Component Results in Increased Impingement Free Range of Motion in a Reverse Shoulder Arthroplasty Model.","authors":"Dalton Dale Schroeder, Alexander Borsgard, Timothy Lee Rossman, Cory Michael Stewart","doi":"10.1177/24715492241237034","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Shoulder arthroplasties have been demonstrated to provide reliable pain relief as well as functional benefits. The advent of the reverse shoulder arthroplasty allowed for expanded indications for shoulder replacement. Several studies comparing the outcomes of anatomic and reverse total shoulder arthroplasties have demonstrated decreased range of motion in the reverse arthroplasty cohort, especially in internal rotation. The authors hypothesized that slight modifications to the humeral component of a reverse shoulder arthroplasty could result in increased impingement free range of motion without significant sacrifices to stability.</p><p><strong>Methods: </strong>A reverse shoulder arthroplasty model was fashioned to mimic a setting of anterior mechanical impingement after replacement. Sequential resections were taken from the anterior aspect of the polyethylene up to a resection of 10 mm. A solid modeling software was utilized to compare the experimental group to the control group with regard to impingement free motion. Finite element analysis was subsequently utilized to assess stability of the construct in comparison to the nonmodified polyethylene.</p><p><strong>Results: </strong>Impingement free internal rotation increased minimally at 3 mm of resection but considerably at each further increase in resection. A resection of 10 mm resulted roughly 30% improvement in impingement free internal rotation. Instability in this model increased with modifications beyond 7 mm.</p><p><strong>Conclusion: </strong>Slight alterations to the geometry of the humeral tray and polyethene components can result in improvements in impingement-free internal rotation without substantial increased instability in this model. Further work is needed to determine in vivo implications of modifications to the humeral tray and polyethylene.</p>","PeriodicalId":73942,"journal":{"name":"Journal of shoulder and elbow arthroplasty","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11020712/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of shoulder and elbow arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/24715492241237034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Shoulder arthroplasties have been demonstrated to provide reliable pain relief as well as functional benefits. The advent of the reverse shoulder arthroplasty allowed for expanded indications for shoulder replacement. Several studies comparing the outcomes of anatomic and reverse total shoulder arthroplasties have demonstrated decreased range of motion in the reverse arthroplasty cohort, especially in internal rotation. The authors hypothesized that slight modifications to the humeral component of a reverse shoulder arthroplasty could result in increased impingement free range of motion without significant sacrifices to stability.

Methods: A reverse shoulder arthroplasty model was fashioned to mimic a setting of anterior mechanical impingement after replacement. Sequential resections were taken from the anterior aspect of the polyethylene up to a resection of 10 mm. A solid modeling software was utilized to compare the experimental group to the control group with regard to impingement free motion. Finite element analysis was subsequently utilized to assess stability of the construct in comparison to the nonmodified polyethylene.

Results: Impingement free internal rotation increased minimally at 3 mm of resection but considerably at each further increase in resection. A resection of 10 mm resulted roughly 30% improvement in impingement free internal rotation. Instability in this model increased with modifications beyond 7 mm.

Conclusion: Slight alterations to the geometry of the humeral tray and polyethene components can result in improvements in impingement-free internal rotation without substantial increased instability in this model. Further work is needed to determine in vivo implications of modifications to the humeral tray and polyethylene.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
修改肱骨组件可增加反向肩关节成形术模型中的撞击自由活动范围。
介绍:肩关节置换术已被证明能可靠地缓解疼痛并改善功能。反向肩关节置换术的出现扩大了肩关节置换的适应症。几项比较解剖型和反向全肩关节置换术效果的研究表明,反向置换术患者的活动范围缩小,尤其是内旋。作者假设,对反向肩关节置换术的肱骨组件稍作改动,可在不明显牺牲稳定性的情况下增加无撞击的活动范围:方法:制作了一个反向肩关节置换模型,以模拟置换术后前方机械性撞击的情况。从聚乙烯前侧开始依次切除,直至切除 10 毫米。利用实体建模软件比较实验组和对照组的无撞击运动。随后,利用有限元分析评估了与未改性聚乙烯相比的结构稳定性:结果:在切除 3 毫米时,撞击自由内旋的增加幅度很小,但每增加一毫米,增加幅度就很大。切除 10 毫米后,撞击自由内旋大约提高了 30%。该模型的不稳定性随着切除量超过 7 毫米而增加:结论:对肱骨托和聚乙烯组件的几何形状稍作改动,可改善无撞击内旋,而不会大幅增加该模型的不稳定性。还需要进一步研究,以确定对肱骨托和聚乙烯进行改良的体内影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
10 weeks
期刊最新文献
Locked Stem Reverse Total Shoulder Arthroplasty for Complex Proximal Humerus Fracture in the Elderly: Clinical and Radiological Short-Term Results. Corticosteroid Infiltration to Treat Shoulder Stiffness After Rotator Cuff Repair. Modified Weaver Dunn Versus Ligamentous Reconstruction Grafts in Chronic Acromioclavicular Joint Dislocation: A Systematic Review and Meta-Analysis of Comparative Studies. Short-Term Radiographic Outcomes of Bone Versus Metallic Augmented, Central Screw Type Baseplate in Reverse Total Shoulder Arthroplasty: Matched Case-Control Study. Distal Clavicular Resection Worsens Outcomes in Rotator Cuff Repair: A National Database Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1