Kai J Wessel, Charalampos Varnava, Philipp Wiebringhaus, Mirkka Hiort, Tobias Hirsch, Maximilian Kückelhaus
{"title":"[Robot-assisted Microsurgery for Autologous Breast Reconstruction - Robotic Breast Reconstruction].","authors":"Kai J Wessel, Charalampos Varnava, Philipp Wiebringhaus, Mirkka Hiort, Tobias Hirsch, Maximilian Kückelhaus","doi":"10.1055/a-2241-5737","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>With the introduction of novel surgical robots and surgical microscopes for the special needs of open microsurgery, the concept of robotic-assisted microsurgery is gaining popularity. While initial preclinical studies indicate a steep learning curve, favourable ergonomics and improved precision, albeit with an increased operating time, data on the clinical application of the new systems is still limited. This study describes our first clinical experience with robotic-assisted autologous breast reconstruction and outlines the opportunities and limitations of the approach.</p><p><strong>Patients and methods: </strong>Our retrospective data analysis included a total of 28 patients who underwent unilateral robotic-assisted autologous breast reconstruction between July 2022 and August 2023. We applied a combined approach using the Symani Surgical System together with the RoboticScope. Descriptive evaluation of patient characteristics, surgical data and complications was performed.</p><p><strong>Results: </strong>Average patient age was 54.3±11.1 years and average BMI was 26.5±3.5 kg/m<sup>2</sup>. Twenty-six patients received a DIEP flap and 2 patients received a PAP flap, the flaps being connected to the internal mammary artery in 22 cases, to a perforator of the internal mammary artery in 5 cases, and to a branch of the thoracodorsal artery in one case. The average incision-suture time was 267±89 min, with an average ischaemia time of 86±20 min and duration of the arterial anastomosis of 29±12 min. In two cases, immediate intraoperative anastomosis revision was performed, but no flap loss occurred.</p><p><strong>Conclusion: </strong>The results of this study demonstrate the safe feasibility of robot-assisted autologous breast reconstruction using a combination of Symani and RoboticScope. In the future, special attention should be paid to minimally invasive techniques of flap harvest and connecting vessel preparation.</p>","PeriodicalId":55075,"journal":{"name":"Handchirurgie Mikrochirurgie Plastische Chirurgie","volume":"56 2","pages":"114-121"},"PeriodicalIF":0.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Handchirurgie Mikrochirurgie Plastische Chirurgie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2241-5737","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/26 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: With the introduction of novel surgical robots and surgical microscopes for the special needs of open microsurgery, the concept of robotic-assisted microsurgery is gaining popularity. While initial preclinical studies indicate a steep learning curve, favourable ergonomics and improved precision, albeit with an increased operating time, data on the clinical application of the new systems is still limited. This study describes our first clinical experience with robotic-assisted autologous breast reconstruction and outlines the opportunities and limitations of the approach.
Patients and methods: Our retrospective data analysis included a total of 28 patients who underwent unilateral robotic-assisted autologous breast reconstruction between July 2022 and August 2023. We applied a combined approach using the Symani Surgical System together with the RoboticScope. Descriptive evaluation of patient characteristics, surgical data and complications was performed.
Results: Average patient age was 54.3±11.1 years and average BMI was 26.5±3.5 kg/m2. Twenty-six patients received a DIEP flap and 2 patients received a PAP flap, the flaps being connected to the internal mammary artery in 22 cases, to a perforator of the internal mammary artery in 5 cases, and to a branch of the thoracodorsal artery in one case. The average incision-suture time was 267±89 min, with an average ischaemia time of 86±20 min and duration of the arterial anastomosis of 29±12 min. In two cases, immediate intraoperative anastomosis revision was performed, but no flap loss occurred.
Conclusion: The results of this study demonstrate the safe feasibility of robot-assisted autologous breast reconstruction using a combination of Symani and RoboticScope. In the future, special attention should be paid to minimally invasive techniques of flap harvest and connecting vessel preparation.
期刊介绍:
In Originalarbeiten und Fallberichten finden Sie die neuesten Informationen über:
Diagnostik
Verfahrenswahl
state of the art / neueste Techniken
rekonstruktive Verfahren
Behandlung infolge von Traumata oder OP
Bewertung der Ergebnisse
Klinische Forschung
Interessante Darstellung der neuesten Erkenntnisse in Originalarbeiten und Fallberichten. Exzellent
veranschaulicht durch ein klares Layout und reiche Bebilderung. Überzeugen Sie sich selbst!
Organschaften
Organ der Deutschsprachigen Arbeitsgemeinschaft für Handchirurgie, Deutschen Gesellschaft für Handchirurgie und Österreichischen Gesellschaft für Handchirurgie
Organ der Deutschsprachigen Arbeitsgemeinschaft für Mikrochirurgie der peripheren Nerven und Gefäße
Organ der Deutschen Gesellschaft der Plastischen, Rekonstruktiven und Ästhetischen Chirurgen