Complications of Nasal Tip Stabilizing Grafts with Autologous Versus Irradiated Homologous Costal Cartilage in Septorhinoplasty: A Systematic Review.

IF 1.6 3区 医学 Q2 SURGERY Facial Plastic Surgery & Aesthetic Medicine Pub Date : 2024-11-01 Epub Date: 2024-04-26 DOI:10.1089/fpsam.2023.0337
Haley R Kowalski, Manuela von Sneidern, Ronald S Wang, Gregory Laynor, Judy W Lee
{"title":"Complications of Nasal Tip Stabilizing Grafts with Autologous Versus Irradiated Homologous Costal Cartilage in Septorhinoplasty: A Systematic Review.","authors":"Haley R Kowalski, Manuela von Sneidern, Ronald S Wang, Gregory Laynor, Judy W Lee","doi":"10.1089/fpsam.2023.0337","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Complications associated with the use of autologous and homologous costal cartilage for nasal tip stabilizing grafts in septorhinoplasty are not well understood. <b>Objective:</b> The authors review current literature to evaluate complications associated with autologous and irradiated homologous costal cartilage (IHCC) used for septal extension and columellar strut grafts in rhinoplasty. <b>Method:</b> A comprehensive literature search was conducted in PubMed, Embase, Scopus, Cochrane Central Register of Controlled Trials (CENTRAL), and ClinicalTrials.gov. Articles that used autologous or IHCC for either septal extension or columellar strut grafts in patients undergoing septorhinoplasty were included. The primary outcomes analyzed were postoperative complications. <b>Results:</b> A total of 14 studies representing 1358 patients were included. The pooled complication rate was 4.7%. IHCC grafts were associated with a higher incidence of complications (<i>n</i> = 21, 5.0% vs. <i>n</i> = 44, 4.6%, <i>p</i> = 0.01). Resorption was the most common complication in the IHCC group and occurred significantly more frequently than in the autologous costal cartilage (ACC) group (<i>n</i> = 10, 2.4% vs. <i>n</i> = 5, 0.49%, <i>p</i> = 0.002). Deviation/warping was the most common complication in the ACC group (<i>n</i> = 16, 1.7%). <b>Conclusion:</b> Autologous and irradiated homologous costal rhinoplasties remain safe procedures. The increased incidence of resorption associated with IHCC grafts should be considered during preoperative planning.</p>","PeriodicalId":48487,"journal":{"name":"Facial Plastic Surgery & Aesthetic Medicine","volume":" ","pages":"775-781"},"PeriodicalIF":1.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Facial Plastic Surgery & Aesthetic Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/fpsam.2023.0337","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/26 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Complications associated with the use of autologous and homologous costal cartilage for nasal tip stabilizing grafts in septorhinoplasty are not well understood. Objective: The authors review current literature to evaluate complications associated with autologous and irradiated homologous costal cartilage (IHCC) used for septal extension and columellar strut grafts in rhinoplasty. Method: A comprehensive literature search was conducted in PubMed, Embase, Scopus, Cochrane Central Register of Controlled Trials (CENTRAL), and ClinicalTrials.gov. Articles that used autologous or IHCC for either septal extension or columellar strut grafts in patients undergoing septorhinoplasty were included. The primary outcomes analyzed were postoperative complications. Results: A total of 14 studies representing 1358 patients were included. The pooled complication rate was 4.7%. IHCC grafts were associated with a higher incidence of complications (n = 21, 5.0% vs. n = 44, 4.6%, p = 0.01). Resorption was the most common complication in the IHCC group and occurred significantly more frequently than in the autologous costal cartilage (ACC) group (n = 10, 2.4% vs. n = 5, 0.49%, p = 0.002). Deviation/warping was the most common complication in the ACC group (n = 16, 1.7%). Conclusion: Autologous and irradiated homologous costal rhinoplasties remain safe procedures. The increased incidence of resorption associated with IHCC grafts should be considered during preoperative planning.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在鼻中隔成形术中使用自体与辐照自体肋软骨进行鼻尖稳定移植物的并发症:系统回顾
背景:在鼻中隔成形术中使用自体和同源肋软骨作为鼻尖稳定移植物的相关并发症尚不十分清楚。目的:作者回顾了目前的文献,评估了在鼻中隔成形术中使用自体和同源肋软骨作为鼻尖稳定移植物的并发症:作者回顾了目前的文献,以评估鼻中隔成形术中用于鼻中隔延长和结肠支柱移植物的自体和辐照自体肋软骨(IHCC)的相关并发症。方法:在 PubMed、Embase、Scopus、Cochrane 对照试验中央注册中心 (CENTRAL) 和 ClinicalTrials.gov 中进行了全面的文献检索。纳入了在接受鼻中隔成形术的患者中使用自体或 IHCC 进行鼻中隔延伸或结肠支架移植的文章。分析的主要结果是术后并发症。结果:共纳入了代表 1358 名患者的 14 项研究。合并并发症发生率为 4.7%。IHCC移植物的并发症发生率较高(n = 21,5.0% vs. n = 44,4.6%,p = 0.01)。吸收是IHCC组最常见的并发症,发生率明显高于自体肋软骨(ACC)组(n = 10,2.4% vs. n = 5,0.49%,p = 0.002)。偏离/翘曲是 ACC 组最常见的并发症(n = 16,1.7%)。结论自体和辐照同源肋软骨鼻整形术仍然是安全的手术。术前规划时应考虑到 IHCC 移植物吸收的发生率增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.70
自引率
30.00%
发文量
159
期刊最新文献
Association Between Symptoms of Body Dysmorphia and Social Media Usage: A Cross-Generational Comparison. Maximizing Septal Cartilage and Bone Harvest for Autologous Nasal Septal Grafts in Congenital Cleft Nasal Deformity. Bell's Palsy-Unclear Terminology and Definitions Impede Progress. Dorsal Hump Reduction and Keystone Injury in Human Anatomic Specimens. Effectiveness of Isotretinoin Administration in Rhinoplasty: A Systematic Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1