Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic.

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Advanced Prosthodontics Pub Date : 2024-04-01 Epub Date: 2024-04-24 DOI:10.4047/jap.2024.16.2.105
Tae-Yub Kwon, Seung-Hee Han, Du-Hyeong Lee, Jin-Woo Park, Young Kyung Kim
{"title":"Effect of universal adhesive pretreatments on the bond strength durability of conventional and adhesive resin cements to zirconia ceramic.","authors":"Tae-Yub Kwon, Seung-Hee Han, Du-Hyeong Lee, Jin-Woo Park, Young Kyung Kim","doi":"10.4047/jap.2024.16.2.105","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia.</p><p><strong>Materials and methods: </strong>Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test.</p><p><strong>Results: </strong>The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (<i>P</i> < .001), the PF/CON obtained a higher SBS value than the DL/CON (<i>P</i> < .001) and no decrease even after thermocycling (<i>P</i> = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (<i>P</i> < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (<i>P</i> = .002), showing no significant decrease after thermocycling (<i>P</i> > .05). The initial SBS of the PF/PBU was similar to the PF/CON (<i>P</i> = .999), but the value decreased after thermocycling (<i>P</i> < .001).</p><p><strong>Conclusion: </strong>The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058350/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2024.16.2.105","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to evaluate the effect of pretreatment of three different universal adhesives (Single Bond Universal [SBU], All-Bond Universal [ABU], and Prime&Bond universal [PBU]) on the bonding durability of an adhesive (Panavia F 2.0, PF) and a conventional (Duo-Link, DL) resin cements to air-abraded zirconia.

Materials and methods: Rectangular-shaped zirconia specimens were prepared. The chemical composition and surface energy parameters of the materials were studied by Fourier transform infrared spectroscopy and contact angle measurement, respectively. To evaluate resin bonding to the zirconia, all the bonding specimens were immersed in water for 24 h and the specimens to be aged were additionally thermocycled 10000 times before the shear bond strength (SBS) test.

Results: The materials showed different surface energy parameters, including the degree of hydrophilicity/hydrophobicity. While the DL/CON (no pretreatment) showed the lowest SBS and a significant decrease in the value after thermocycling (P < .001), the PF/CON obtained a higher SBS value than the DL/CON (P < .001) and no decrease even after thermocycling (P = .839). When the universal adhesives were used with DL, their SBS values were higher than the CON (P < .05), but the trend was adhesive-specific. In conjunction with PF, the PF/SBU produced the highest SBS followed by the PF/ABU (P = .002), showing no significant decrease after thermocycling (P > .05). The initial SBS of the PF/PBU was similar to the PF/CON (P = .999), but the value decreased after thermocycling (P < .001).

Conclusion: The universal adhesive pretreatment did not necessarily show a synergistic effect on the bonding performance of an adhesive resin cement, whereas the pretreatment was beneficial to bond strength and durability of a conventional resin cement.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通用粘合剂预处理对氧化锆陶瓷传统粘合剂和粘合剂树脂水门汀粘合强度耐久性的影响。
目的:本研究旨在评估三种不同通用粘合剂(Single Bond Universal [SBU]、All-Bond Universal [ABU] 和 Prime&Bond universal [PBU])的预处理对粘合剂(Panavia F 2.0,PF)和传统树脂水门汀(Duo-Link,DL)与空气消融氧化锆的粘接耐久性的影响:制备矩形氧化锆试样。分别通过傅里叶变换红外光谱和接触角测量法研究了材料的化学成分和表面能参数。为了评估树脂与氧化锆的粘结情况,所有粘结试样都在水中浸泡了 24 小时,待老化的试样在进行剪切粘结强度(SBS)测试前还进行了 10000 次热循环:结果:材料的表面能参数不同,包括亲水性/疏水性。DL/CON(无预处理)的 SBS 值最低,且在热循环后显著下降(P < .001),而 PF/CON 的 SBS 值高于 DL/CON(P < .001),即使在热循环后也没有下降(P = .839)。当通用粘合剂与 DL 一起使用时,其 SBS 值高于 CON(P < .05),但这种趋势是粘合剂特有的。与 PF 一起使用时,PF/SBU 产生的 SBS 最高,其次是 PF/ABU (P = .002),在热循环后没有出现显著下降 (P > .05)。PF/PBU 的初始 SBS 与 PF/CON 相似(P = .999),但热循环后其值下降(P < .001):结论:通用粘合剂预处理并不一定会对粘合剂树脂粘结剂的粘结性能产生协同效应,而预处理则有利于传统树脂粘结剂的粘结强度和耐久性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
期刊最新文献
A novel brief questionnaire using a face rating scale to assess dental anxiety and fear. Clinical performance of implant-assisted removable partial dentures using implant surveyed crowns: a systematic review and meta-analysis. Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis. Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study. Recording maximal intercuspation and border positions of the mandible with intraoral scanner using the acquisition software's multi-occlusion function.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1