Inclinometers and Apps Are Better than Goniometers, Measuring Knee Extension Range of Motion in Anterior Cruciate Ligament Patients: Reliability and Minimal Detectable Change for the Three Devices.

IF 1.6 4区 医学 Q3 ORTHOPEDICS Journal of Knee Surgery Pub Date : 2024-10-01 Epub Date: 2024-05-07 DOI:10.1055/a-2321-0516
Michail Pantouveris, Roula Kotsifaki, Rodney Whiteley
{"title":"Inclinometers and Apps Are Better than Goniometers, Measuring Knee Extension Range of Motion in Anterior Cruciate Ligament Patients: Reliability and Minimal Detectable Change for the Three Devices.","authors":"Michail Pantouveris, Roula Kotsifaki, Rodney Whiteley","doi":"10.1055/a-2321-0516","DOIUrl":null,"url":null,"abstract":"<p><p>Knee extension range of motion (ROM) measurement is important in patients with anterior cruciate ligament (ACL) injury. The main objective is to evaluate the reliability and the minimal detectable change (MDC) of three methods of measuring knee extension ROM in ACL patients. The three common goniometric devices were a universal goniometer, an inclinometer, and a smartphone app. During a single-visit, knee extension ROM was measured in both knees of 92 ACL-injured or -reconstructed patients by two testers blinded to the other's measures. Intrarater, interrater, and test-retest intraclass correlation coefficients (ICC<sub>2,1</sub>) were calculated. Intrarater ICC<sub>2,1</sub> was excellent for the three devices ranging from 0.92 to 0.94, with the inclinometer yielding the best results (ICC<sub>2,1</sub> = 0.94 [95% confidence interval, CI: 0.91-0.96]). Interrater ICC<sub>2,1</sub>, however, varied from 0.36 to 0.80. The inclinometer and the smartphone app yielded similar results 0.80 (95% CI: 0.71-0.86) and 0.79 (95% CI: 0.70-0.86), respectively, whereas the universal goniometer was 0.36 (95% CI: 0.17-0.53). Test-retest ICC<sub>2,1</sub> for the inclinometer was 0.89 (95% CI: 0.84-0.93), 0.86 (95% CI: 0.79-0.91) for the app, and 0.83 (95% CI:0.74-0.89) for the goniometer. The intrarater, interrater, and test-retest MDC<sub>95</sub> values ranged from 2.0 to 3.5, 3.7 to 10.4, and 2.6 to 5.4 degrees, respectively. The goniometer was the least reliable. The inclinometer is the recommended device due to its highest ICC scores among the three devices and ease of use.</p>","PeriodicalId":48798,"journal":{"name":"Journal of Knee Surgery","volume":" ","pages":"821-827"},"PeriodicalIF":1.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Knee Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2321-0516","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Knee extension range of motion (ROM) measurement is important in patients with anterior cruciate ligament (ACL) injury. The main objective is to evaluate the reliability and the minimal detectable change (MDC) of three methods of measuring knee extension ROM in ACL patients. The three common goniometric devices were a universal goniometer, an inclinometer, and a smartphone app. During a single-visit, knee extension ROM was measured in both knees of 92 ACL-injured or -reconstructed patients by two testers blinded to the other's measures. Intrarater, interrater, and test-retest intraclass correlation coefficients (ICC2,1) were calculated. Intrarater ICC2,1 was excellent for the three devices ranging from 0.92 to 0.94, with the inclinometer yielding the best results (ICC2,1 = 0.94 [95% confidence interval, CI: 0.91-0.96]). Interrater ICC2,1, however, varied from 0.36 to 0.80. The inclinometer and the smartphone app yielded similar results 0.80 (95% CI: 0.71-0.86) and 0.79 (95% CI: 0.70-0.86), respectively, whereas the universal goniometer was 0.36 (95% CI: 0.17-0.53). Test-retest ICC2,1 for the inclinometer was 0.89 (95% CI: 0.84-0.93), 0.86 (95% CI: 0.79-0.91) for the app, and 0.83 (95% CI:0.74-0.89) for the goniometer. The intrarater, interrater, and test-retest MDC95 values ranged from 2.0 to 3.5, 3.7 to 10.4, and 2.6 to 5.4 degrees, respectively. The goniometer was the least reliable. The inclinometer is the recommended device due to its highest ICC scores among the three devices and ease of use.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
倾角仪和应用程序比动态关节角度计更好。测量前交叉韧带患者的膝关节伸展活动范围。三种设备的可靠性和最小检测变化。
前言:膝关节伸展运动范围(ROM)的测量对于前交叉韧带(ACL)损伤患者非常重要。主要目的是评估前交叉韧带患者膝关节伸展活动度测量的三种方法的可靠性和最小可检测变化(MDC):三种常见的动态关节角度计:通用动态关节角度计、倾角计和智能手机应用程序:方法:在一次就诊中,由两名测试者对92名前交叉韧带损伤或重建患者的双膝伸展活动度进行测量,测试者对另一方的测量结果置盲。计算评分者内部、评分者之间和测试-重复的类内相关系数(ICC2,1):三种设备的评分者内部相关系数(ICC(2,1))在 0.93-0.96 之间,智能手机应用程序的评分者内部相关系数(ICC(2,1)=0.96, [95%CI:0.89-0.95])最佳。然而,评分者之间的 ICC(2,1) 在 0.36 到 0.80 之间。倾角仪和智能手机应用程序的结果相似,分别为 0.80(95%CI:0.71-0.86)和 0.79(95%CI:0.70-0.86),而通用动态关节角度计的结果为 0.36(95%CI:0.17-0.53)。倾角仪的测试再测 ICC(2,1) 为 0.89 (95%CI:0.84-0.93), 应用程序为 0.86 (95%CI:0.79-0.91), 而动态关节角度计为 0.83 (95%CI:0.74-0.89).评分者内部、评分者之间和测试-重复测试的MDC95值分别为1.6°至3.5°、3.7°至10.4°和2.6°至5.4°:角度计的可靠性最低。与智能手机应用程序相比,倾角仪因其易于使用而成为推荐设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.50
自引率
5.90%
发文量
139
期刊介绍: The Journal of Knee Surgery covers a range of issues relating to the orthopaedic techniques of arthroscopy, arthroplasty, and reconstructive surgery of the knee joint. In addition to original peer-review articles, this periodical provides details on emerging surgical techniques, as well as reviews and special focus sections. Topics of interest include cruciate ligament repair and reconstruction, bone grafting, cartilage regeneration, and magnetic resonance imaging.
期刊最新文献
Articular Cartilage Damage in the Patellofemoral Compartment at ACL Reconstruction Predicts Poor Postoperative Subjective Outcomes in Patients Age 40 and Older. Survey Results Concerning Current Trends in Meniscus Repair Indications and Preferences from Members of the Pediatric Research in Sports Medicine (PRiSM) Society. Impact of Joint Laxity on 2-Year KOOS Outcomes of Posterior Stabilized Total Knee Arthroplasty. Interatrial Wall Abnormality is Associated with Adverse Same-Admission Outcomes Following Total Knee Arthroplasty. Survivorship of Primary NexGen Knee Replacement: Comparing Cementless Trabecular Metal to Other Designs of Tibial Component.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1