Quality control performance evaluation of uMI550 digital PET-CT by utilising LYSO crystal natural radioactivity of 176Lu

IF 2.5 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Radiography Pub Date : 2024-05-07 DOI:10.1016/j.radi.2024.04.022
M.K. Singh , V. Dhull , M. Vishwakarma
{"title":"Quality control performance evaluation of uMI550 digital PET-CT by utilising LYSO crystal natural radioactivity of 176Lu","authors":"M.K. Singh ,&nbsp;V. Dhull ,&nbsp;M. Vishwakarma","doi":"10.1016/j.radi.2024.04.022","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>Quality Control (QC) of the Positron Emission Tomography-Computed Tomography (PET-CT) system must be performed prior to the PET-CT acquisition to ensure the reproducibility as per the manufacturer recommendation. In this study we have evaluated the performance of daily PET QC test by utilising lutetium yttrium oxyorthosilicate (LYSO) scintillation crystal natural radioactivity of <sup>176</sup>Lu as a source of radiation to perform the PET uCare.iQC with uMI550 digital PET-CT system. This was also compared with existing radioactive external source-based QC test with other manufacturer PET-CT systems.</p></div><div><h3>Method</h3><p>This radioactive source free daily QC study was performed on uMI550 digital PET-CT system. The daily QC data report was captured and interpreted. This PET-CT system has unique feature that utilises the inherent property of LYSO crystal that is <sup>176</sup>Lu with natural radioactivity abundance of 2.6%. The Lutetium-176 (<sup>176</sup>Lu) radioactivity is used to perform the daily QC in PET in place of external radioactive source of Germanium-68 (<sup>68</sup>Ge). This feature work automatically in preschedule manner to complete the daily QC at preset time in the morning and system get ready after the QC test.</p></div><div><h3>Results</h3><p>Over 120 automatic PET daily uCare.iQC test were performed. The daily PET QC test was prescheduling setup for 6:00 am in every morning. No failure on daily QC test were observed. The QC parameters and system parameters consistency was observed.</p></div><div><h3>Conclusion</h3><p>It was concluded that the daily PET QC can be performed by utilising LYSO crystal inherent natural radioactivity of <sup>176</sup>Lu as a source of radiation to perform the test as replacement of external <sup>68</sup>Ge radioactive source.</p></div><div><h3>Implication for practice</h3><p>PET-CT daily QC by utilizing the <sup>176</sup>Lu radioactivity of LYSO crystal results in reducing the radiation exposure to operation staff and reducing operational cost by elimination 68Ge shield source Phantom.</p></div>","PeriodicalId":47416,"journal":{"name":"Radiography","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1078817424000993","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Quality Control (QC) of the Positron Emission Tomography-Computed Tomography (PET-CT) system must be performed prior to the PET-CT acquisition to ensure the reproducibility as per the manufacturer recommendation. In this study we have evaluated the performance of daily PET QC test by utilising lutetium yttrium oxyorthosilicate (LYSO) scintillation crystal natural radioactivity of 176Lu as a source of radiation to perform the PET uCare.iQC with uMI550 digital PET-CT system. This was also compared with existing radioactive external source-based QC test with other manufacturer PET-CT systems.

Method

This radioactive source free daily QC study was performed on uMI550 digital PET-CT system. The daily QC data report was captured and interpreted. This PET-CT system has unique feature that utilises the inherent property of LYSO crystal that is 176Lu with natural radioactivity abundance of 2.6%. The Lutetium-176 (176Lu) radioactivity is used to perform the daily QC in PET in place of external radioactive source of Germanium-68 (68Ge). This feature work automatically in preschedule manner to complete the daily QC at preset time in the morning and system get ready after the QC test.

Results

Over 120 automatic PET daily uCare.iQC test were performed. The daily PET QC test was prescheduling setup for 6:00 am in every morning. No failure on daily QC test were observed. The QC parameters and system parameters consistency was observed.

Conclusion

It was concluded that the daily PET QC can be performed by utilising LYSO crystal inherent natural radioactivity of 176Lu as a source of radiation to perform the test as replacement of external 68Ge radioactive source.

Implication for practice

PET-CT daily QC by utilizing the 176Lu radioactivity of LYSO crystal results in reducing the radiation exposure to operation staff and reducing operational cost by elimination 68Ge shield source Phantom.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 LYSO 晶体天然放射性 176Lu 对 uMI550 数字 PET-CT 进行质量控制性能评估
目的 正电子发射断层扫描-计算机断层扫描(PET-CT)系统的质量控制(QC)必须在 PET-CT 采集之前进行,以确保制造商建议的可重复性。在这项研究中,我们利用镥钇氧硅酸盐(LYSO)闪烁晶体的天然放射性 176Lu 作为辐射源,对使用 uMI550 数字 PET-CT 系统进行 PET uCare.iQC 的日常 PET QC 测试的性能进行了评估。方法在 uMI550 数字 PET-CT 系统上进行了这项无放射源日常质量控制研究。采集并解读了每日质控数据报告。该 PET-CT 系统的独特之处在于利用了 LYSO 晶体的固有特性,即天然放射性丰度为 2.6% 的 176Lu。镥-176(176Lu)放射性被用来代替外部放射源锗-68(68Ge)执行 PET 的日常质量控制。结果进行了 120 多次自动 PET 日常 uCare.iQC 测试。每日 PET QC 测试的预设时间为每天早上 6:00。未发现日常质量控制测试失败的情况。结论利用 LYSO 晶体固有的 176Lu 天然放射性作为辐射源进行测试,可以取代外部 68Ge 放射源,从而进行 PET 日常 QC。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Radiography
Radiography RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.70
自引率
34.60%
发文量
169
审稿时长
63 days
期刊介绍: Radiography is an International, English language, peer-reviewed journal of diagnostic imaging and radiation therapy. Radiography is the official professional journal of the College of Radiographers and is published quarterly. Radiography aims to publish the highest quality material, both clinical and scientific, on all aspects of diagnostic imaging and radiation therapy and oncology.
期刊最新文献
CT metal artefact reduction for hip and shoulder implants using novel algorithms and machine learning: A systematic review with pairwise and network meta-analyses Clinical insights into cross-sectional imaging integration in radiography education Paediatric diagnostic reference levels for common computed tomography procedures: A systematic review “Making it work in the face of extreme adversity” - Exploring perceptions for the future of the imaging and oncology workforce using ‘soundbite’ interviews Radiographer Education and Learning in Artificial Intelligence (REAL-AI): A survey of radiographers, radiologists, and students’ knowledge of and attitude to education on AI
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1