Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus

IF 1.8 4区 医学 Q3 OPHTHALMOLOGY Journal of Ophthalmology Pub Date : 2024-05-06 DOI:10.1155/2024/2173860
Mika Ichimura, Satoshi Ueki, Takeo Fukuchi
{"title":"Test-Retest of the Spot Vision Screener among Children with Ophthalmological Diseases including Strabismus","authors":"Mika Ichimura, Satoshi Ueki, Takeo Fukuchi","doi":"10.1155/2024/2173860","DOIUrl":null,"url":null,"abstract":"<i>Background</i>. The spot vision screener (SVS) has been widely used for eye health examinations of infants and young children. The purpose of this study was to evaluate the reproducibility of two SVS measurements in children with ophthalmological diseases. <i>Methods</i>. 29 patients aged 15 years or younger who visited our hospital for refraction examinations with SVS before and at least 60 minutes after administration of 2 drops of 1% cyclopentolate ophthalmic solution (before and after cycloplegia) were included in this study. Two SVS measurements were made before and after cycloplegia, respectively. Intraclass correlation coefficients (ICCs) and Bland–Altman analysis for spherical, spherical equivalent (SE), cylindrical, J0, and J45 values before and after cycloplegia were analyzed. <i>Results</i>. The mean age ± standard deviation (SD) of the 29 patients was 7.6 ± 2.4 years. There were 11 males and 18 females. The mean spherical values based on the SVS before and after cycloplegia were 0.42 ± 1.67 diopter (D), and 1.47 ± 2.23 D for the first measurement and 0.60 ± 1.74 D, and 1.42 ± 2.27 D for the second measurement, respectively. The mean cylindrical values based on SVS before and after cycloplegia were −1.45 ± 0.96 D and −1.65 ± 0.89 D for the first measurement and −1.58 ± 1.13 D and −1.66 ± 0.91 D for the second measurement, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values before cycloplegia were 0.95, 0.98, 0.83, 0.86, and 0.86, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values after cycloplegia were 0.99, 0.99, 0,87, 0.73, and 0.80, respectively. The Bland–Altman analysis of the first and second spherical and SE values before cycloplegia showed fan-shaped variation as hyperopia increased. <i>Conclusions</i>. Two consecutive SVS refraction measurements have a high degree of reproducibility for spherical and SE values but a low degree for cylindrical, J0, and J45 values. From these results, multiple measurements are required to obtain reliable results for cylindrical values.","PeriodicalId":16674,"journal":{"name":"Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.8000,"publicationDate":"2024-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1155/2024/2173860","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background. The spot vision screener (SVS) has been widely used for eye health examinations of infants and young children. The purpose of this study was to evaluate the reproducibility of two SVS measurements in children with ophthalmological diseases. Methods. 29 patients aged 15 years or younger who visited our hospital for refraction examinations with SVS before and at least 60 minutes after administration of 2 drops of 1% cyclopentolate ophthalmic solution (before and after cycloplegia) were included in this study. Two SVS measurements were made before and after cycloplegia, respectively. Intraclass correlation coefficients (ICCs) and Bland–Altman analysis for spherical, spherical equivalent (SE), cylindrical, J0, and J45 values before and after cycloplegia were analyzed. Results. The mean age ± standard deviation (SD) of the 29 patients was 7.6 ± 2.4 years. There were 11 males and 18 females. The mean spherical values based on the SVS before and after cycloplegia were 0.42 ± 1.67 diopter (D), and 1.47 ± 2.23 D for the first measurement and 0.60 ± 1.74 D, and 1.42 ± 2.27 D for the second measurement, respectively. The mean cylindrical values based on SVS before and after cycloplegia were −1.45 ± 0.96 D and −1.65 ± 0.89 D for the first measurement and −1.58 ± 1.13 D and −1.66 ± 0.91 D for the second measurement, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values before cycloplegia were 0.95, 0.98, 0.83, 0.86, and 0.86, respectively. The ICCs for the first and second spherical, SE, cylindrical, J0, and J45 values after cycloplegia were 0.99, 0.99, 0,87, 0.73, and 0.80, respectively. The Bland–Altman analysis of the first and second spherical and SE values before cycloplegia showed fan-shaped variation as hyperopia increased. Conclusions. Two consecutive SVS refraction measurements have a high degree of reproducibility for spherical and SE values but a low degree for cylindrical, J0, and J45 values. From these results, multiple measurements are required to obtain reliable results for cylindrical values.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
斜视等眼科疾病患儿的点视力筛查测试-复测
背景。点视力筛查仪(SVS)已被广泛用于婴幼儿的眼健康检查。本研究旨在评估两种 SVS 测量方法在眼科疾病患儿中的重现性。研究方法本研究选取了 29 名 15 岁或 15 岁以下到我院接受屈光检查的患者,在滴用 2 滴 1%环戊托品眼药水之前和之后至少 60 分钟(在环状麻痹之前和之后)用 SVS 进行测量。分别在环形麻痹前后进行了两次 SVS 测量。对环麻痹前后的球面、球面等值(SE)、圆柱、J0 和 J45 值的类内相关系数(ICC)和 Bland-Altman 分析进行了分析。结果。29 名患者的平均年龄为 7.6±2.4 岁。其中男性 11 人,女性 18 人。第一次测量和第二次测量的平均球面视力值分别为 0.60 ± 1.74 D 和 1.42 ± 2.27 D,而第一次测量和第二次测量的平均球面视力值分别为 0.42 ± 1.67 D 和 1.47 ± 2.23 D。第一次测量和第二次测量的圆柱值分别为-1.58 ± 1.13 D 和-1.66 ± 0.91 D。第一次和第二次测量球面、SE、圆柱、J0 和 J45 值的 ICC 分别为 0.95、0.98、0.83、0.86 和 0.86。环形瞳孔术后第一和第二个球面、SE、圆柱、J0 和 J45 值的 ICC 分别为 0.99、0.99、0,87、0.73 和 0.80。对屈光手术前的第一和第二球面和 SE 值进行的 Bland-Altman 分析显示,随着远视度数的增加,其变化呈扇形。结论。连续两次 SVS 屈光度测量的球镜和 SE 值具有较高的可重复性,但柱镜、J0 和 J45 值的可重复性较低。从这些结果来看,需要多次测量才能获得可靠的圆柱度值结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Ophthalmology
Journal of Ophthalmology MEDICINE, RESEARCH & EXPERIMENTAL-OPHTHALMOLOGY
CiteScore
4.30
自引率
5.30%
发文量
194
审稿时长
6-12 weeks
期刊介绍: Journal of Ophthalmology is a peer-reviewed, Open Access journal that publishes original research articles, review articles, and clinical studies related to the anatomy, physiology and diseases of the eye. Submissions should focus on new diagnostic and surgical techniques, instrument and therapy updates, as well as clinical trials and research findings.
期刊最新文献
MicroRNA Regulation for Inflammasomes in High Glucose-Treated ARPE-19 Cells. Axial Length Shortening after Combined Repeated Low-Level Red-Light Therapy in Poor Responders of Orthokeratology in Myopic Children. Characteristics of Peripheral Retinal Refraction and Its Role in Children with Different Refractive States. The Association of Myopia Progression with Changes in Retinal Thickness among Primary School Students with Myopia. Neural Changes after Vision Therapy in Convergence Insufficiency: A Systematic Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1