Maximilian Tscharre, David Mutschlechner, Thomas Schlöglhofer, Dominik Wiedemann, Daniel Zimpfer, Thomas Gremmel
{"title":"Omission of Antiplatelet Therapy in Patients With HeartMate 3 Left Ventricular Assist Devices: A Systematic Review and Meta-Analysis.","authors":"Maximilian Tscharre, David Mutschlechner, Thomas Schlöglhofer, Dominik Wiedemann, Daniel Zimpfer, Thomas Gremmel","doi":"10.1097/MAT.0000000000002225","DOIUrl":null,"url":null,"abstract":"<p><p>The HeartMate 3 (HM3) left ventricular assist device has decreased thromboembolic events and minimized the risk of pump thrombosis. However, bleeding complications due to combined antithrombotic therapy with a vitamin K antagonist (VKA) and aspirin remain high. Only limited data on the safety of VKA monotherapy in HM3 patients are available. A systematic search on the main databases was performed. Observational data and randomized trials were eligible for this analysis. As primary endpoint, we analyzed hemocompatibility-related adverse events (HRAE). As secondary endpoints, we investigated the individual components of the primary endpoint. The analysis was carried out using the odds ratio (OR) as outcome measure. A random-effects model was fitted to the data. Five manuscripts fulfilled the inclusion criteria. These trials included 785 patients (381 on VKA monotherapy, 404 on VKA and aspirin). VKA monotherapy significantly reduced HRAE (OR: 0.11 [95% confidence interval {CI}: 0.02-0.59], p = 0.01, I2 = 87%). The reduction was driven by a decrease in bleeding complications (OR: 0.12 [95% CI: 0.02-0.62], p = 0.01, I2 = 86%) without increasing the rates of thromboembolic events (OR: 0.69 [95% CI: 0.26-1.81], p = 0.45, I = 0%). Vitamin K antagonist monotherapy is associated with a significant reduction of bleeding events without increasing the risk of thromboembolic complications in HM3 patients.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":"957-963"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002225","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The HeartMate 3 (HM3) left ventricular assist device has decreased thromboembolic events and minimized the risk of pump thrombosis. However, bleeding complications due to combined antithrombotic therapy with a vitamin K antagonist (VKA) and aspirin remain high. Only limited data on the safety of VKA monotherapy in HM3 patients are available. A systematic search on the main databases was performed. Observational data and randomized trials were eligible for this analysis. As primary endpoint, we analyzed hemocompatibility-related adverse events (HRAE). As secondary endpoints, we investigated the individual components of the primary endpoint. The analysis was carried out using the odds ratio (OR) as outcome measure. A random-effects model was fitted to the data. Five manuscripts fulfilled the inclusion criteria. These trials included 785 patients (381 on VKA monotherapy, 404 on VKA and aspirin). VKA monotherapy significantly reduced HRAE (OR: 0.11 [95% confidence interval {CI}: 0.02-0.59], p = 0.01, I2 = 87%). The reduction was driven by a decrease in bleeding complications (OR: 0.12 [95% CI: 0.02-0.62], p = 0.01, I2 = 86%) without increasing the rates of thromboembolic events (OR: 0.69 [95% CI: 0.26-1.81], p = 0.45, I = 0%). Vitamin K antagonist monotherapy is associated with a significant reduction of bleeding events without increasing the risk of thromboembolic complications in HM3 patients.
期刊介绍:
ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world.
The official publication of the American Society for Artificial Internal Organs.